Error log
The Error log allows you to see the number of times that a speed error is produced.
1.In the Diagnostics menu, select the “ERROR LOG” and accept it by pressing the JustGoTM/ENTER key.
2.You can see all the errors and the number of times that they occurred.
3.Press the CLEAR/STOP key to exit this test or press the JustGoTM/ENTER to clear all errors.
NOTE – The table of errors can be viewed at the end of this document.
Current test
The current test allows you to see the voltage and amperage in the motor.
1.In the Diagnostics menu, select “CURRENT TEST”. The motor will start and will reach 2.0 mph (or 3.2 km/h).
2.Press the JustGoTM/ENTER key to proceed.
3.Walk on the treadmill for a couple of minutes and the value of the current and voltage at the motor will appear on the central information window.
4.Vary the speed to ensure that you get good readings for different speeds.
5.Press the CLEAR/STOP key to terminate the test.
NOTE – During this test, the amperage and the tension will be shown on the central information window in the following format: 3.1 A, 20V.
Here 3.1 A stands for 3.1 Amps and 20 V stands for 20 Volts DC.
The value of the amperage must never exceed 15 amps (10 amps for international version).
Speed Sensor test
The Speed Sensor test allows you to see whether your speed sensor circuit is functional or not.
1.In the Diagnostics menu, select the “SPEED SENSOR TEST” and accept it by pressing the JustGoTM/ENTER key.
2.Press the JustGoTM/ENTER key to proceed and step off the machine. Allow the belt to reach 2.0 mph or 3.2 km/h.
3.A message will be displayed if the circuit is “GOOD” or “BAD” on the central information window:
•Check if your speed sensor is connected.
•Check if your optical disc is clean and that there is no dirt blocking the speed sensor.
4.Press the CLEAR/STOP key to terminate the test.
Maintenance
The maintenance menu allows you to see the average value of the current drawn by the motor. It also allows you to reset this counter.
A first threshold has been set to make sure that the normal high limit of current drawn by the motor will not be exceeded. When that level is reached, the user will get the message DECK MAINTENANCE IS REQUIRED and a diamond sign will be displayed on the main screen. The message and sign will be displayed between each new exercise. After the maintenance has been done and reset in the diagnostics menu, the notice will go away until there is a new rise of current.
If the maintenance is not done on the deck surface when required, a second threshold will trigger not too high above the first one. Another notice with a square sign on the main display will come up. At that point the machine will not start again until the deck maintenance is done and the maintenance has been reset in the diagnostics menu.
28