The walking belt is off-center or slips when walked on a. If the walking belt is off-center, first remove the

key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the hex key to turn the left idler roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the left idler roller bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller bolts clock- wise, 1/4 of a turn. When the walking belt is cor- rectly tightened, you should be able to lift each side of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and carefully walk on the treadmill for a few minutes. Repeat until the walking belt is prop- erly tightened.

The cross walk arms squeak during use

a. (Note: Correcting this problem requires a small amount of white marine grease, available at hard- ware stores.) Turn the Resistance Knob (88) coun- terclockwise and remove it. Next, remove the Resistance Cone (85) with the Cross Walk Arm (82).

Apply a thin layer of white marine grease to the outer surface of the Resistance Cone (85). Then, reattach the Resistance Cone with the Cross Walk Arm (82) and the Resistance Knob (88).

a

b

a

 

88

82

85

 

24

Image 24
Contents QUESTIONS? Model No. PFTL99909.0 Serial NoMon.-Fri a.m.-6 p.m. MT Sat a.m.-4 p.m. MT On the WEBTable of Contents Important Precautions Cord immediately after use, before cleaning Before YOU Begin Assembly Page Ful not to pinch the Wire Harness Do not overtighten the Locknut the Wheel Must turn freelyTouch the Upright do not fully tighten Bolts yet Do not fully fold the Frame yet Do not overtighten the Locknut Wheel must turn freelyTighten the Bolts yet Be Damaged When the Power is Nected PROPERLY, the Console MAYTurned on See steps 5 and 8. Tighten the M10 x 96mm Bolts Attach the other Cross Walk Arm 82 as de- scribed above Operation and Adjustment HOW to Plug in the Power CordPRE-LUBRICATED Walking Belt Console Diagram Features of the ConsoleHOW to Turn on the Power HOW to USE the Manual ModeInsert the key into the console Measure your heart rate if desired Turn on the fan if desiredHOW to USE a Preset Workout Information Mode HOW to USE the Cross Walk ArmsHOW to Fold and Move the Treadmill HOW to Move the TreadmillHOW to Lower the Treadmill for USE Troubleshooting Problem The power does not turn onProblem The power turns off during use Compatible with GFCI-equipped outletsProblem The walking belt slows when walked on TopProblem Solution Exercise Guidelines Exercise IntensityWorkout Guidelines Exercise FrequencyR0209A Key No. Qty. DescriptionDescription Exploded Drawing A-Model No. PFTL99909.0 R0209A Exploded Drawing B-Model No. PFTL99909.0 R0209A Exploded Drawing C-Model No. PFTL99909.0 R0209A Exploded Drawing D-Model No. PFTL99909.0 R0209A Ordering Replacement Parts Limited WarrantyIcon Health & Fitness, Inc., 1500 S W., Logan, UT