Suunto None manual Symbol Explanation, Compass settings, Calibration

Page 14

Table 4.1. Locked bearing symbols

Symbol Explanation

You are traveling towards the locked bearing

You are 90 (or 270) degrees from the locked bearing

You are 180 degrees from the locked bearing

You are 120 (or 240) degrees from the locked bearing

4.3.3. Compass settings

You can define the compass settings ( calibration, declination and time-out) when in COMPASS mode:

Calibration

Because of changes in the surrounding magnetic field, the Suunto Cobra3 electronic compass occasionally needs to be re-calibrated. During the calibration process, the compass adjusts itself to the surrounding magnetic field and to tilting. As a basic rule, you should calibrate the compass whenever it doesn’t seem to operate properly, or after replacing the dive computer's battery.

First the compass is level calibrated and after a successful level calibration, the compass is tilt calibrated. The tilt calibration compensates for tilting the compass in any direction in angles of up to 45°.

Strong electromagnetic fields, such as power lines, stereo speakers, and magnets can affect the compass calibration. It is therefore advisable to calibrate the compass if your Suunto Cobra3 has been exposed to these fields.

NOTE

NOTE

When traveling overseas, it is recommended that you recalibrate the compass at the new location before using it.

Remember to hold the Suunto Cobra3 level during the level calibration process. A deviation of ± 5° is allowed in any direction from the horizontal plane during level calibration.

To calibrate the compass:

14

Image 14
Contents COBRA3 Time Tank pressure Before Diving Intellectual Property Welcome to the World of Suunto Diving Instruments Not for Professional USE! Suunto dive computers are Before DIVING. Make sure that you fully understand the useSerious injury or death That tend to increase the risk of decompression illness DCIDives That Require Decompression Stops are not Batteries. Recycle or dispose of used batteries properly Nitrox mode, as well as from AIR or Nitrox mode to GaugeMode even during the no-fly time Before the instrument has counted down the no-fly timeSuunto AT a Glance Button symbols and functionsSymbol Button Press Main functions Navigating in the menusDown Setting the time Time mode settingsSetting the alarm Setting the dateSetting the tones Setting the unitsSetting the backlight AC water contactsCompass display Learning how to use your compassDisplays by pressing the UP/DOWN buttons Locking a bearingCalibration Symbol ExplanationCompass settings Declination Time-outEmergency ascents Before DivingSuunto RGBM/Deep Stop Algorithm Dive computer limitationsPreset alarm types Alarm type Audible and visual alarmsAlarm type NitroxError conditions Alarm type Alarm reasonAlarm is activated Omitted decompressionSetting the depth alarm Connecting Suunto Cobra3 to a regulatorDive mode settings Setting the dive-time alarmBottom time, for example Setting the nitrox valuesSetting the personal/altitude adjustments Are stored until changedSetting the Rgbm values Setting the sample rateSetting the Safety Stops/Deep Stops Setting the tank pressure alarmActivation and pre-checks Accessing Dive modeDive mode activation Diving at altitude Battery power indicationAlt. adjustment value Altitude range How the Altitude value is setRgbm setting Desired Tables Effect Personal adjustmentsPersonal Condition Desired tables Adjustment Value Mandatory Safety Stops Safety StopsRecommended Safety Stops Deep stops Order to perform the necessary dive pre-checks Diving in AIR mode DIVEairDiving Basic dive dataBookmark Tank pressure dataDecompression dives Ascent rate indicatorLow Air Pressure Warnings Ceiling, ceiling zone, floor and decompression range Display below the floorDisplay above the ceiling Display above the floorDisplay at the ceiling zone Default nitrox settings Diving in Nitrox mode DIVEnitroxBefore diving in Nitrox mode Oxygen displaysGas change and multiple breathing gas mixes Diving in Gauge mode DIVEgaugeOxygen limit fraction OLF Modes before the no fly time has counted down Gauge mode does not provide decompression informationThere is no ascent rate monitoring in the Gauge mode Surface interval Alarms Symbol on displayAfter Diving Dive numberingFlying after diving Plan modeDive Planning mode PLANnodec Dive numbering shown during dive planning Simulation Mode PLANsimulatorMode Dive SimulatorMemory mode Dive logbook MEMLogbookDive series if the no-fly time has not ended. See .2. Dive Providing that the battery has been replaced according toInstructions Numbering for further informationUnit and the downloadable Suunto Dive Manager software Suunto Dive Manager SDMPage Care and Maintenance of MY Suunto Diving Computer Water Contacts and Push ButtonsWarranty FAQsBattery replacement and strap kits must be used Replacing the battery Battery ReplacementBattery kit Required toolsBattery compartment lid, indicating a leak Technical Data Rgbm Suunto Rgbm adaptive decompressionDiver Attention Symbol Advice to Extend Surface Interval No-decompression limitsAltitude diving Oxygen exposurePatent notice Intellectual PropertyCopyright Trademark 12.2. CE DisclaimersUser’s responsibility Warranty Period Exclusions and LimitationsLimitation of Liability Access to Suunto warranty serviceOther important notices Page Disposal of the Device Glossary EAD EANNoaa Customer Service Contacts CopyrightTWO Year Warranty Suunto Oy 9/2008, 10/2008, 11/2008