Suunto None Setting the sample rate, Setting the Safety Stops/Deep Stops, Setting the Rgbm values

Page 21

5.8.5. Setting the sample rate

The sample rate controls how often the depth, time, tank pressure, and water temperature is stored in the memory.

You can set the dive profile sample rate to 1, 10, 20, 30, or 60 seconds. The factory default setting is 20 seconds.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.6. Setting the Safety Stops/Deep Stops

The Deep Stop setting allows you to view Deep Stops. If Deep Stops are set to OFF, only the traditional Safety Stop calculation is used.

If set to ON, iterative Deep Stops will be prompted as well. The length of the individual Deep Stops can be set to 1 or 2 minutes.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.7. Setting the RGBM values

For certain divers and diving conditions, it may be desirable to set the attenuated RGBM mode. The selection is displayed during the DIVE mode startup. The options are full RGBM effects (100%), and attenuated RGBM (50%).

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.8. Setting the units

Use Unit Settings to choose between metric (meters/celsius/bar) and imperial (feet/fahrenheit/psi) units.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.8.9. Setting the tank pressure alarm

The tank pressure alarm can be set "ON" or "OFF" and in the range of 10 - 200 bar. The alarm is the secondary cylinder pressure alarm point. The alarm is activated when the tank pressure drops below the set limit. The 50 bar alarm, however, is fixed and cannot be changed.

21

Image 21
Contents COBRA3 Time Tank pressure Before Diving Intellectual Property Welcome to the World of Suunto Diving Instruments Serious injury or death Before DIVING. Make sure that you fully understand the useNot for Professional USE! Suunto dive computers are That tend to increase the risk of decompression illness DCIDives That Require Decompression Stops are not Mode even during the no-fly time Nitrox mode, as well as from AIR or Nitrox mode to GaugeBatteries. Recycle or dispose of used batteries properly Before the instrument has counted down the no-fly timeSymbol Button Press Main functions Button symbols and functionsSuunto AT a Glance Navigating in the menusDown Setting the alarm Time mode settingsSetting the time Setting the dateSetting the backlight Setting the unitsSetting the tones AC water contactsDisplays by pressing the UP/DOWN buttons Learning how to use your compassCompass display Locking a bearingSymbol Explanation Compass settingsCalibration Time-out DeclinationSuunto RGBM/Deep Stop Algorithm Before DivingEmergency ascents Dive computer limitationsAlarm type Audible and visual alarmsPreset alarm types Alarm type NitroxAlarm is activated Alarm type Alarm reasonError conditions Omitted decompressionDive mode settings Connecting Suunto Cobra3 to a regulatorSetting the depth alarm Setting the dive-time alarmSetting the personal/altitude adjustments Setting the nitrox valuesBottom time, for example Are stored until changedSetting the Safety Stops/Deep Stops Setting the sample rateSetting the Rgbm values Setting the tank pressure alarmAccessing Dive mode Dive mode activationActivation and pre-checks Alt. adjustment value Altitude range Battery power indicationDiving at altitude How the Altitude value is setPersonal adjustments Personal Condition Desired tables Adjustment ValueRgbm setting Desired Tables Effect Safety Stops Recommended Safety StopsMandatory Safety Stops Deep stops Diving Diving in AIR mode DIVEairOrder to perform the necessary dive pre-checks Basic dive dataTank pressure data BookmarkAscent rate indicator Low Air Pressure WarningsDecompression dives Display below the floor Ceiling, ceiling zone, floor and decompression rangeDisplay above the floor Display at the ceiling zoneDisplay above the ceiling Before diving in Nitrox mode Diving in Nitrox mode DIVEnitroxDefault nitrox settings Oxygen displaysDiving in Gauge mode DIVEgauge Oxygen limit fraction OLFGas change and multiple breathing gas mixes Gauge mode does not provide decompression information There is no ascent rate monitoring in the Gauge modeModes before the no fly time has counted down After Diving Alarms Symbol on displaySurface interval Dive numberingPlan mode Dive Planning mode PLANnodecFlying after diving Mode Simulation Mode PLANsimulatorDive numbering shown during dive planning Dive SimulatorDive logbook MEMLogbook Memory modeInstructions Providing that the battery has been replaced according toDive series if the no-fly time has not ended. See .2. Dive Numbering for further informationSuunto Dive Manager SDM Unit and the downloadable Suunto Dive Manager softwarePage Water Contacts and Push Buttons Care and Maintenance of MY Suunto Diving ComputerFAQs Battery replacement and strap kits must be usedWarranty Battery kit Battery ReplacementReplacing the battery Required toolsBattery compartment lid, indicating a leak Technical Data Suunto Rgbm adaptive decompression RgbmNo-decompression limits Diver Attention Symbol Advice to Extend Surface IntervalOxygen exposure Altitude divingIntellectual Property Copyright TrademarkPatent notice Disclaimers User’s responsibility12.2. CE Exclusions and Limitations Warranty PeriodAccess to Suunto warranty service Other important noticesLimitation of Liability Page Disposal of the Device EAD EAN GlossaryNoaa Copyright Customer Service ContactsTWO Year Warranty Suunto Oy 9/2008, 10/2008, 11/2008