Suunto None manual Activation and pre-checks, Accessing Dive mode, Dive mode activation

Page 22

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

5.9. Activation and pre-checks

This section describes how to activate the DIVE mode and explains the pre-checks that it is highly recommended you perform before you get into the water.

5.9.1. Accessing DIVE mode

The Suunto Cobra3 has three diving modes: AIR mode for diving with standard air only, NITROX mode for diving with oxygen enriched mixtures, and GAUGE mode for use as a bottom timer and for freediving.

The OFF mode disables the DIVE mode, and allows the TIME mode to be used underwater. The chosen dive mode is displayed when the DIVE mode is accessed, and you can toggle between the submodes by pressing the UP/DOWN buttons.

5.9.2. DIVE mode activation

The dive computer activates automatically when submerged deeper than 0.5 m/1.5 ft.

However, it is necessary to activate the DIVE mode BEFORE diving to check the altitude and personal adjustment settings, battery condition, oxygen settings etc.

After activation, all graphical display elements are turned on, and the backlight and the beep are activated. After this, the selected altitude and personal settings are displayed, as well as the RGBM and Deep Stop status. A few seconds later the battery power indicator is shown.

At this time, perform your pre-checks, making sure that:

the instrument operates in the correct mode and provides a complete display (AIR/NITROX/GAUGE mode)

the battery level is ok

the altitude, personal adjustment, Safety/Deep stops, and RGBM settings are correct

the instrument displays correct units of measurement (Metric/Imperial)

the instrument displays the correct temperature and depth (0.0 m/0 ft)

the alarm beeps

And, if set to NITROX mode, make sure that:

the correct number of mixes is set and that the oxygen percentages are adjusted according to the measured nitrox blends in your cylinders

22

Image 22
Contents COBRA3 Time Tank pressure Before Diving Intellectual Property Welcome to the World of Suunto Diving Instruments Not for Professional USE! Suunto dive computers are Before DIVING. Make sure that you fully understand the useSerious injury or death That tend to increase the risk of decompression illness DCIDives That Require Decompression Stops are not Batteries. Recycle or dispose of used batteries properly Nitrox mode, as well as from AIR or Nitrox mode to GaugeMode even during the no-fly time Before the instrument has counted down the no-fly timeSuunto AT a Glance Button symbols and functionsSymbol Button Press Main functions Navigating in the menusDown Setting the time Time mode settingsSetting the alarm Setting the dateSetting the tones Setting the unitsSetting the backlight AC water contactsCompass display Learning how to use your compassDisplays by pressing the UP/DOWN buttons Locking a bearingCompass settings Symbol ExplanationCalibration Declination Time-outEmergency ascents Before DivingSuunto RGBM/Deep Stop Algorithm Dive computer limitationsPreset alarm types Alarm type Audible and visual alarmsAlarm type NitroxError conditions Alarm type Alarm reasonAlarm is activated Omitted decompressionSetting the depth alarm Connecting Suunto Cobra3 to a regulatorDive mode settings Setting the dive-time alarmBottom time, for example Setting the nitrox valuesSetting the personal/altitude adjustments Are stored until changedSetting the Rgbm values Setting the sample rateSetting the Safety Stops/Deep Stops Setting the tank pressure alarmDive mode activation Accessing Dive modeActivation and pre-checks Diving at altitude Battery power indicationAlt. adjustment value Altitude range How the Altitude value is setPersonal Condition Desired tables Adjustment Value Personal adjustmentsRgbm setting Desired Tables Effect Recommended Safety Stops Safety StopsMandatory Safety Stops Deep stops Order to perform the necessary dive pre-checks Diving in AIR mode DIVEairDiving Basic dive dataBookmark Tank pressure dataLow Air Pressure Warnings Ascent rate indicatorDecompression dives Ceiling, ceiling zone, floor and decompression range Display below the floorDisplay at the ceiling zone Display above the floorDisplay above the ceiling Default nitrox settings Diving in Nitrox mode DIVEnitroxBefore diving in Nitrox mode Oxygen displaysOxygen limit fraction OLF Diving in Gauge mode DIVEgaugeGas change and multiple breathing gas mixes There is no ascent rate monitoring in the Gauge mode Gauge mode does not provide decompression informationModes before the no fly time has counted down Surface interval Alarms Symbol on displayAfter Diving Dive numberingDive Planning mode PLANnodec Plan modeFlying after diving Dive numbering shown during dive planning Simulation Mode PLANsimulatorMode Dive SimulatorMemory mode Dive logbook MEMLogbookDive series if the no-fly time has not ended. See .2. Dive Providing that the battery has been replaced according toInstructions Numbering for further informationUnit and the downloadable Suunto Dive Manager software Suunto Dive Manager SDMPage Care and Maintenance of MY Suunto Diving Computer Water Contacts and Push ButtonsBattery replacement and strap kits must be used FAQsWarranty Replacing the battery Battery ReplacementBattery kit Required toolsBattery compartment lid, indicating a leak Technical Data Rgbm Suunto Rgbm adaptive decompressionDiver Attention Symbol Advice to Extend Surface Interval No-decompression limitsAltitude diving Oxygen exposureCopyright Trademark Intellectual PropertyPatent notice User’s responsibility Disclaimers12.2. CE Warranty Period Exclusions and LimitationsOther important notices Access to Suunto warranty serviceLimitation of Liability Page Disposal of the Device Glossary EAD EANNoaa Customer Service Contacts CopyrightTWO Year Warranty Suunto Oy 9/2008, 10/2008, 11/2008