Suunto None manual Noaa

Page 57

Multi level dive

Nitrox

NOAA

No decompression time

No decompression dive

NO DEC TIME

OEA = EAN = EANx

OLF

OTU

Oxygen tolerance unit

Oxygen limit fraction

O2%

Oxygen partial pressure

PO2

RGBM

Reduced Gradient Bubble Model Repetitive dive

Residual nitrogen

SURF TIME

Surface interval time

Tissue group

Whole-body toxicity

A single or repetitive dive that includes time spent at various depths and whose no decompression limits are therefore not determined solely by the maximum depth attained.

In sports diving, refers to any mix with a higher fraction of oxygen than standard air.

United States National Oceanic and Atmospheric Administration.

The maximum amount of time a diver may remain at a particular depth without having to make decompression stops during the subsequent ascent.

Any dive which permits a direct, uninterrupted ascent to the surface at any time.

Abbreviation for no decompression time limit.

Abbreviations for oxygen enriched air nitrox.

Abbreviation for oxygen limit fraction.

Abbreviation for oxygen tolerance unit.

Used to measure the whole-body-toxicity.

A term used by Suunto for the values displayed in the oxygen toxicity bar graph. The value is either the CNS% or the OTU%.

Oxygen percentage or oxygen fraction in the breathing gas. Standard air has 21% oxygen.

Limits the maximum depth to which the nitrox mixture can be safely used. The maximum partial pressure limit for enriched air diving is 1.4 bar. The contingency partial pressure limit is 1.6 bar. Dives beyond this limit risk immediate oxygen toxicity.

Abbreviation for oxygen partial pressure.

Abbreviation for Reduced Gradient Bubble Model.

Modern algorithm for tracking both dissolved and free gas in divers.

Any dive whose decompression time limits are affected by residual nitrogen absorbed during previous dives.

The amount of excess nitrogen remaining in a diver after one or more dives.

Abbreviation for surface interval time.

Elapsed time between surfacing from a dive and beginning a descent for the subsequent repetitive dive.

Theoretical concept used to model bodily tissues for the construction of decompression tables or calculations.

Another form of oxygen toxicity, which is caused by prolonged exposure to high oxygen partial pressures. The most common symptoms are irritation in the lungs, a burning sensation in the chest, coughing and reduction of the vital capacity. Also called Pulmonary Oxygen Toxicity. See also OTU.

57

Image 57
Contents COBRA3 Time Tank pressure Before Diving Intellectual Property Welcome to the World of Suunto Diving Instruments Serious injury or death Before DIVING. Make sure that you fully understand the useNot for Professional USE! Suunto dive computers are That tend to increase the risk of decompression illness DCIDives That Require Decompression Stops are not Mode even during the no-fly time Nitrox mode, as well as from AIR or Nitrox mode to GaugeBatteries. Recycle or dispose of used batteries properly Before the instrument has counted down the no-fly timeSymbol Button Press Main functions Button symbols and functionsSuunto AT a Glance Navigating in the menusDown Setting the alarm Time mode settingsSetting the time Setting the dateSetting the backlight Setting the unitsSetting the tones AC water contactsDisplays by pressing the UP/DOWN buttons Learning how to use your compassCompass display Locking a bearingSymbol Explanation Compass settingsCalibration Time-out DeclinationSuunto RGBM/Deep Stop Algorithm Before DivingEmergency ascents Dive computer limitationsAlarm type Audible and visual alarmsPreset alarm types Alarm type NitroxAlarm is activated Alarm type Alarm reasonError conditions Omitted decompressionDive mode settings Connecting Suunto Cobra3 to a regulatorSetting the depth alarm Setting the dive-time alarmSetting the personal/altitude adjustments Setting the nitrox valuesBottom time, for example Are stored until changedSetting the Safety Stops/Deep Stops Setting the sample rateSetting the Rgbm values Setting the tank pressure alarmAccessing Dive mode Dive mode activationActivation and pre-checks Alt. adjustment value Altitude range Battery power indicationDiving at altitude How the Altitude value is setPersonal adjustments Personal Condition Desired tables Adjustment ValueRgbm setting Desired Tables Effect Safety Stops Recommended Safety StopsMandatory Safety Stops Deep stops Diving Diving in AIR mode DIVEairOrder to perform the necessary dive pre-checks Basic dive dataTank pressure data BookmarkAscent rate indicator Low Air Pressure WarningsDecompression dives Display below the floor Ceiling, ceiling zone, floor and decompression rangeDisplay above the floor Display at the ceiling zoneDisplay above the ceiling Before diving in Nitrox mode Diving in Nitrox mode DIVEnitroxDefault nitrox settings Oxygen displaysDiving in Gauge mode DIVEgauge Oxygen limit fraction OLFGas change and multiple breathing gas mixes Gauge mode does not provide decompression information There is no ascent rate monitoring in the Gauge modeModes before the no fly time has counted down After Diving Alarms Symbol on displaySurface interval Dive numberingPlan mode Dive Planning mode PLANnodecFlying after diving Mode Simulation Mode PLANsimulatorDive numbering shown during dive planning Dive SimulatorDive logbook MEMLogbook Memory modeInstructions Providing that the battery has been replaced according toDive series if the no-fly time has not ended. See .2. Dive Numbering for further informationSuunto Dive Manager SDM Unit and the downloadable Suunto Dive Manager softwarePage Water Contacts and Push Buttons Care and Maintenance of MY Suunto Diving ComputerFAQs Battery replacement and strap kits must be usedWarranty Battery kit Battery ReplacementReplacing the battery Required toolsBattery compartment lid, indicating a leak Technical Data Suunto Rgbm adaptive decompression RgbmNo-decompression limits Diver Attention Symbol Advice to Extend Surface IntervalOxygen exposure Altitude divingIntellectual Property Copyright TrademarkPatent notice Disclaimers User’s responsibility12.2. CE Exclusions and Limitations Warranty PeriodAccess to Suunto warranty service Other important noticesLimitation of Liability Page Disposal of the Device EAD EAN GlossaryNoaa Copyright Customer Service ContactsTWO Year Warranty Suunto Oy 9/2008, 10/2008, 11/2008