NOTE

With a range of 1 - 999 minutes, the alarm can be set to your planned

 

bottom time, for example.

5.8.3. Setting the nitrox values

If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder (and additional gases) must always be entered into the computer to ensure correct nitrogen and oxygen calculations. In addition, the oxygen partial pressure limit must be set. When in the NITROX setting mode, the equivalent allowed maximum depth, based on the chosen setting, will also be displayed.

Settings for an additional mix (MIX2) are made similarly, but with the additional selection of “ON” or “OFF”.

In order to minimize the risk of error during a dive, it is highly recommended that the mixes are set in the proper order. This means that as the mix number rises, so does oxygen content, and this is the order they are usually used during the dive. Before a dive, only set to “ON” the mixes you actually have available and remember to check the set values to make sure they are correct.

The default oxygen percentage (O2%) setting is 21% (air) and oxygen partial pressure (PO2) setting 1.4 bar.

After entering values for MIX1, you can enable/disable and set an additional gas mix - MIX2.

ADJUST WITH

ADJUST WITH

UP AND DOWN

UP AND DOWN

BUTTONS.

BUTTONS.

ACCEPT WITH

ACCEPT WITH

SELECT BUTTON.

SELECT BUTTON.

NOTE

If MIX2 is set ON, settings for all mixes are stored until changed. If

 

MIX2 has an oxygen content of 22% or greater, settings for all mixes

 

are stored until changed.

5.8.4. Setting the personal/altitude adjustments

The current Altitude and Personal Adjustment settings are displayed in the startup screen when entering the DIVE mode. If the mode does not match the altitude or personal conditions (see Section 5.9.4. Diving at altitude and Section 5.9.5. Personal adjustments), it is imperative that you enter the correct selection before diving. Use Altitude Adjustment to select the correct altitude and use Personal Adjustment to add an extra level of conservatism.

ADJUST WITH UP AND

DOWN BUTTONS. ACCEPT

WITH SELECT BUTTON.

20

Image 20
Contents COBRA3 Time Tank pressure Before Diving Intellectual Property Welcome to the World of Suunto Diving Instruments Before DIVING. Make sure that you fully understand the use Serious injury or deathNot for Professional USE! Suunto dive computers are That tend to increase the risk of decompression illness DCIDives That Require Decompression Stops are not Nitrox mode, as well as from AIR or Nitrox mode to Gauge Mode even during the no-fly timeBatteries. Recycle or dispose of used batteries properly Before the instrument has counted down the no-fly timeButton symbols and functions Symbol Button Press Main functionsSuunto AT a Glance Navigating in the menusDown Time mode settings Setting the alarmSetting the time Setting the dateSetting the units Setting the backlightSetting the tones AC water contactsLearning how to use your compass Displays by pressing the UP/DOWN buttonsCompass display Locking a bearingCalibration Symbol ExplanationCompass settings Declination Time-outBefore Diving Suunto RGBM/Deep Stop AlgorithmEmergency ascents Dive computer limitationsAudible and visual alarms Alarm typePreset alarm types Alarm type NitroxAlarm type Alarm reason Alarm is activatedError conditions Omitted decompressionConnecting Suunto Cobra3 to a regulator Dive mode settingsSetting the depth alarm Setting the dive-time alarmSetting the nitrox values Setting the personal/altitude adjustmentsBottom time, for example Are stored until changedSetting the sample rate Setting the Safety Stops/Deep StopsSetting the Rgbm values Setting the tank pressure alarmActivation and pre-checks Accessing Dive modeDive mode activation Battery power indication Alt. adjustment value Altitude rangeDiving at altitude How the Altitude value is setRgbm setting Desired Tables Effect Personal adjustmentsPersonal Condition Desired tables Adjustment Value Mandatory Safety Stops Safety StopsRecommended Safety Stops Deep stops Diving in AIR mode DIVEair DivingOrder to perform the necessary dive pre-checks Basic dive dataBookmark Tank pressure dataDecompression dives Ascent rate indicatorLow Air Pressure Warnings Ceiling, ceiling zone, floor and decompression range Display below the floorDisplay above the ceiling Display above the floorDisplay at the ceiling zone Diving in Nitrox mode DIVEnitrox Before diving in Nitrox modeDefault nitrox settings Oxygen displaysGas change and multiple breathing gas mixes Diving in Gauge mode DIVEgaugeOxygen limit fraction OLF Modes before the no fly time has counted down Gauge mode does not provide decompression informationThere is no ascent rate monitoring in the Gauge mode Alarms Symbol on display After DivingSurface interval Dive numberingFlying after diving Plan modeDive Planning mode PLANnodec Simulation Mode PLANsimulator ModeDive numbering shown during dive planning Dive SimulatorMemory mode Dive logbook MEMLogbookProviding that the battery has been replaced according to InstructionsDive series if the no-fly time has not ended. See .2. Dive Numbering for further informationUnit and the downloadable Suunto Dive Manager software Suunto Dive Manager SDMPage Care and Maintenance of MY Suunto Diving Computer Water Contacts and Push ButtonsWarranty FAQsBattery replacement and strap kits must be used Battery Replacement Battery kitReplacing the battery Required toolsBattery compartment lid, indicating a leak Technical Data Rgbm Suunto Rgbm adaptive decompressionDiver Attention Symbol Advice to Extend Surface Interval No-decompression limitsAltitude diving Oxygen exposurePatent notice Intellectual PropertyCopyright Trademark 12.2. CE DisclaimersUser’s responsibility Warranty Period Exclusions and LimitationsLimitation of Liability Access to Suunto warranty serviceOther important notices Page Disposal of the Device Glossary EAD EANNoaa Customer Service Contacts CopyrightTWO Year Warranty Suunto Oy 9/2008, 10/2008, 11/2008