![](/images/new-backgrounds/1246793/246793115x1.webp)
Installation
Electrical connection U.K.
All electrical work should be carried out only by a suitably qualified and compe- tent person, in strict accordance with national and local safety regulations.
The appliance is supplied with a mains cable with moulded plug for connection to a
Connection should be made via a fused plug and suitable switched socket which is easily accessible after installa- tion. For extra safety it is advisable to install a residual current device (RCD), with a trip current of 30 mA (in accor- dance with DIN VDE 0664, VDE 0100, section 739). Do not connect via an ex- tension lead.
Ensure power is not supplied to the ap- pliance while installation work is being carried out.
Important
The wires in the mains lead are col- oured in accordance with the following code:
Green/yellow | = earth |
Blue | = neutral |
Brown | = live |
Where it is necessary to change plugs, if the colours of the wires in the mains lead of this appliance do not corre- spond with the coloured markings iden- tifying the terminals of your plug, pro- ceed as follows:
^The wire which is coloured green and yellow must be connected to the ter- minal in the plug which is marked
with the letter E or by the earth sym- bol z or coloured green, or green and yellow.
^The wire which is coloured blue must be connected to the terminal in the plug which is marked with the letter N or coloured black.
^The wire which is coloured brown must be connected to the terminal in the plug which is marked with the let- ter L or coloured red.
WARNING: THIS APPLIANCE MUST BE EARTHED
58