Internal Components
Chassis Backplane Connections
Dip Switch Bank
Channel E BRIM Connector
Channel F BRIM Connector
EPIM Connector Pins
1926n02
Figure 2-2 EMM-E6 Internal Components
Chassis Backplane Connections
The EMM-E6 connects to the backplane buses of the MMAC chassis through these multipin connectors.
Dip Switch Bank
The EMM-E6 provides a bank of eight dual-position, or “dip” switches. Several of these switches are used for testing purposes during the manufacturing process. The dip switches can also be used to clear the NVRAM of the EMM-E6, which contains configuration and local management settings, or to force the EMM-E6 to request a new firmware image from a properly configured BootP server.
BRIM Connectors
The Channel E and Channel F BRIM connectors allow the EMM-E6 to connect BRIM modules to Ethernet Channels E and F of the EMM-E6.
EMM-E6 Installation Guide | 2-3 |