Cabletron Systems EMM-E6 manual Backplane Test Configuration

Page 40

Chapter 3: Installation

3.6BACKPLANE TEST

Once the EMM-E6 has been installed in the network environment, you may wish to test the operation of the Ethernet bridging functionality and the EMM-E6’s connection to the chassis backplane. Again, you can use two workstations set up as file server and client. See Figure 3-11.

1.After the EMM-E6 is installed in the MMAC, connect the client workstation to the EMM-E6 EPIM 1 port.

2.Connect the server workstation to another Ethernet MIM that is accessible from an Ethernet channel in the MMAC-FNB hub.

3.Send packets between the two workstations to verify the proper operation of the EMM-E6. A “ping” test will send packets from one station to another.

If a failure occurs, contact Cabletron Systems Technical Support.

M5PSM

M5PSM

1926n14

Figure 3-11 Backplane Test Configuration

3-20

EMM-E6 Installation Guide

Image 40
Contents Management Module Installation Guide EMM-E6 Ethernet BridgePage EMM-E6 Installation Guide DOC Notice Cabletron Software Program License Declaration of Conformity Contents Adding Epims Chapter Introduction HOW to USE this ManualEMM-E6 Overview Introduction Document Conventions Following conventions are used throughout this documentRelated Documents Getting HelpChapter Controls and Indicators FaceplateInternal Components Internal Components Epim Connector Pins Ldram Simm Slot Reset CPU B a Stby RCV XMT CLN Lanview LedsLanview Leds EMM-E6 Installation Guide Chapter Installation Unpacking the EMM-E6Perform a second visual inspection of the module Setting Mode Switches EMM-E6 Dip SwitchesEMM-E6 Installation Guide PRE-INSTALLATION Test Pre-Installation Test Configuration Installation Install the EMM-E6 into the MMAC-FNB backplane as followsModule Guide Channels Reset CPU B a Stby RCV XMT CLN Connecting to the Network Connecting a 10BASE-T Segment to an EPIM-TPosition X crossed over RX+ TX+ Position = Not crossed over Cable Pinouts RJ45 Port Connecting a 10BASE-F Segment to an EPIM-F2 or EPIM-F3 ST Connector Insertion Connecting a 10BASE-F Segment to an EPIM-F1 SMA Connector Insertion Connecting an AUI Segment to an EPIM-X or EPIM-AConnecting a 10BASE2 Segment to an EPIM-C 10 BNC Connector Insertion Backplane Test 11 Backplane Test ConfigurationChapter Troubleshooting Using Lanview LedsTroubleshooting Using Lanview Leds Troubleshooting Checklist Troubleshooting Checklist EPIM-A Using the Reset Switch EMM-E6 Installation Guide Physical Specifications Appendix a SpecificationsOperating Specifications Certification Environmental RequirementsCOM Port Pinout Locating Brim Connectors Appendix B Upgrading the EMM-E6To install an EPIM, perform the following steps Adding EpimsSimm Upgrades Locating SIMMsInstalling SIMMs Figure B-3, refer to the procedures belowNetwork Requirements Appendix C Ethernet Cabling Requirements1 10BASE-T Twisted Pair Network Appendix C Ethernet Cabling Requirements Multimode Fiber Optic Network Single Mode Fiber Optic Network 4 10BASE2 Coaxial Cable Network Transceiver RequirementsEMM-E6 Installation Guide Index NumericsIndex-2 EMM-E6 Installation Guide EMM-E6 Lanview LEDsInstallation