GE K400 user manual Standard Accessories DBC-TS series, Optional Accessories DBC-TS series

Page 10

STANDARD ACCESSORIES DBC-TS series

The DBC-TC series is supplied with the following standard accessories:

Operating manual

Set of leads for:

2 test leads and 2 clamps for switch connection

Power supply cable

Removable insert with 3 holes (5, 6.6, 9.8 mm diameter), (3/16, 1/4, 3/8 in. diameter for USA)

Tool for extraction of removable insert

RS232 interface cable (1.5 metre, 5 pin/5 pin)

Traceable calibration certificate

2 spare fuses (see page 4 for more information)

OPTIONAL ACCESSORIES DBC-TS series

Option B1 for DBC 150, reference probe type PT 100, range –50°C to +400°C

Option B2 for DBC 650, reference probe type PT 100, range +50°C to +650°C

Option B3, temperature probe type PT 100, range –50°C to +650°C.

Option D, fast cooling device

Option E, aluminium transit case

Option C1/C2, insert with 2 holes (5 and 13 mm diameter), (3/16, 1/2 in. diameter for USA)

Option C3/C4, insert with 4 holes (3.4, 5, 5, 8.2 mm diameter), (1/8, 3/16, 3/16 and 5/16 in. diameter for USA)

Option C5/C6, blank insert

Option C7/C8, insert with special holes.

K400 Issue No. 1

viii

Image 10
Contents Druck DBC 150/650 Series General Electric Company. All rights reserved Maintenance SafetyPower isolation Technical AdviceSymbols Traceability and Calibration ReportSafety Instructions AbbreviationsTable of Contents CAL Electrical Input Specification DBC-TC models Standard Accessories DBC-TC series Optional Accessories DBC-TC seriesStandard Accessories DBC-TS series Optional Accessories DBC-TS seriesTC Temperature Calibrator TS Temperature SourceIntroduction Automatic Calibration Parts IdentificationDBC-TS Power Supply InstallationTemperature Probes Important Note Use of screw connections for T/C wires Electrical Connections Connection of a Thermocouple sensorConnection of a 3-wire RTD Connection of a 4-wire RTDOperating procedure GeneralCalibration with external reference probe External probe connections OPERATI0N Numeric keys +/- keyKey Arrow keysSystem Set-up Screen Menu selection screenWorking screen Help/Info screen Self-test screenFunction Modes Reading of the generated temperature Dual display generated temperature and an input test optionInternal reference probe Temperature Reference SelectionExternal reference probe SEL RTD System Set-up Language setting Temperature unit settingDigital interface settings Key-padaudio signalPrinter settings CalibrationProtection code Testing Modes Direct mode 150.00 CStep mode Fixed step selection19.00 C Ramp mode 50.00 CPreset values mode Switch Test Measuring an InputThermocouple Testing 148.00 CSetting Cold Junction Compensation InternalCAL Mode DirectAbsolute SpanReading RTD Measurements Pt-100 Using the keys, select the required method and press ent Reading Current Measurements CAL Voltage Measurements high level CAL Volt Voltage Measurements low level Resistance Measurement DBC Series Serial Commands Protocol Serial CommunicationTS/ TC Read AaOM 1? Preset mode French German Italian Portuguese Spanish Write Par = floating point Important Note CalibrationCalibration of the standard Reference Probe Input REF RTD Calibration of the millivolt input ranges DBC-TC only Calibration of the Volt input range DBC-TC only Calibration of the mA input range DBC-TC onlyCalibration of the resistance Ohm input ranges DBC-TC only Fault Finding Maintenance Cleaning InstructionsStandard Specification Technical SpecificationCommon specification Electrical Input Specifications DBC-TC models Input Range Resolution Accuracy Days Year