GE K400 Safety, Test leads, Power isolation, Toxic Materials, Maintenance, Technical Advice

Page 3

Introduction

This technical manual provides operating instructions for the Druck DBC Series of Dry Well Calibrators.

Safety

The manufacturer has designed this equipment to be safe when operated using the procedures detailed in this manual. Do not use this equipment for any other purpose than that stated.

This publication contains operating and safety instructions that must be followed to ensure safe operation and to maintain the equipment in a safe condition. The safety instructions are either warnings or cautions issued to protect the user and the equipment from injury or damage.

Use suitably qualified * technicians and good engineering practice for all procedures in this publication.

Test leads

Only use the test leads supplied with the instrument, do not use these test leads with any other equipment.

Power isolation

Access to the power supply isolator switch must not be obstructed.

Toxic Materials

There are no known toxic materials used in construction of this equipment.

Maintenance

The equipment must be maintained using the procedures in this publication. Further manufacturer’s procedures should be carried out by authorized service agents or the manufacturer’s service departments.

Technical Advice

For technical advice contact the manufacturer.

*A qualified technician must have the necessary technical knowledge, documentation, special test equipment and tools to carry out the required work on this equipment.

This equipment meets the requirements of all relevant European safety directives. The equipment carries the CE mark.

K400 Issue No. 1

i

Image 3
Contents Druck DBC 150/650 Series General Electric Company. All rights reserved Technical Advice SafetyPower isolation MaintenanceTraceability and Calibration Report SymbolsAbbreviations Safety InstructionsTable of Contents CAL Electrical Input Specification DBC-TC models Optional Accessories DBC-TC series Standard Accessories DBC-TC seriesOptional Accessories DBC-TS series Standard Accessories DBC-TS seriesTS Temperature Source TC Temperature CalibratorIntroduction Parts Identification Automatic CalibrationDBC-TS Installation Power SupplyTemperature Probes Important Note Electrical Connections Connection of a Thermocouple sensor Use of screw connections for T/C wiresConnection of a 4-wire RTD Connection of a 3-wire RTDGeneral Operating procedureCalibration with external reference probe External probe connections OPERATI0N Arrow keys +/- keyKey Numeric keysMenu selection screen System Set-up ScreenWorking screen Self-test screen Help/Info screenDual display generated temperature and an input test option Function Modes Reading of the generated temperatureTemperature Reference Selection Internal reference probeExternal reference probe SEL RTD Temperature unit setting System Set-up Language settingKey-padaudio signal Digital interface settingsCalibration Printer settingsProtection code 150.00 C Testing Modes Direct modeFixed step selection Step mode19.00 C 50.00 C Ramp modePreset values mode Measuring an Input Switch Test148.00 C Thermocouple TestingInternal Setting Cold Junction CompensationDirect CAL ModeSpan AbsoluteReading RTD Measurements Pt-100 Using the keys, select the required method and press ent Reading Current Measurements CAL Voltage Measurements high level CAL Volt Voltage Measurements low level Resistance Measurement Serial Communication DBC Series Serial Commands ProtocolTS/ TC Read AaOM 1? Preset mode French German Italian Portuguese Spanish Write Par = floating point Calibration Important NoteCalibration of the standard Reference Probe Input REF RTD Calibration of the millivolt input ranges DBC-TC only Calibration of the mA input range DBC-TC only Calibration of the Volt input range DBC-TC onlyCalibration of the resistance Ohm input ranges DBC-TC only Fault Finding Cleaning Instructions MaintenanceTechnical Specification Standard SpecificationCommon specification Input Range Resolution Accuracy Days Year Electrical Input Specifications DBC-TC models

K400 specifications

The GE K400 is a prominent engine in the aviation industry, renowned for its exceptional performance and innovative technologies. Designed primarily for regional and business aircraft, the K400 engine exemplifies General Electric's commitment to engineering excellence and efficiency.

One of the standout features of the GE K400 is its advanced turbofan design. This design enables the engine to deliver significant thrust while ensuring fuel efficiency. With a bypass ratio that optimizes airflow, the K400 reduces the overall fuel consumption, making it an eco-friendly choice for operators. This fuel efficiency is crucial in today’s aviation landscape, where sustainability and operational costs are paramount.

The K400 is equipped with cutting-edge materials that contribute to its performance characteristics. The engine incorporates advanced composite materials and titanium alloys, which not only enhance durability but also reduce the overall weight. This lightweight design directly impacts the aircraft's payload capacity and range, offering operators greater flexibility and performance.

Moreover, the GE K400 features a sophisticated digital engine control system. This system provides precise monitoring and adjustments to the engine's performance, ensuring optimal operation under various conditions. The integration of such advanced technology allows for increased reliability and reduced maintenance requirements, further reducing operational costs for airlines.

In terms of noise reduction, the K400 conforms to stringent noise regulations, making it a quieter option in the regional aviation sector. The engine's design includes noise-dampening technologies that minimize sound emissions, benefitting both passengers and nearby communities.

Another characteristic of the GE K400 is its versatility. The engine can power a variety of aircraft types, making it a flexible option for manufacturers and operators alike. This adaptability is particularly important in a rapidly changing aviation market, where the ability to meet diverse customer needs is paramount.

Overall, the GE K400 represents a significant advancement in aviation engine technology. Its combination of fuel efficiency, advanced materials, digital control systems, and noise reduction features sets it apart in the competitive landscape of regional and business aviation. As airlines continue to seek innovative solutions to enhance their operations, the GE K400 stands out as a top-tier choice that embodies performance and sustainability.