Kenmore 3405602 owner manual Exhaust

Page 14

STEP lb. Cut 1 inch of insulation from the end of each insulated wire. Shape

the end of each wire into a "U" shaped hook.

STEP 2. Remove hold-down screw and terminal block cover.

STEP 4. Loosen or remove terminal block screws. Connect the neutral wire (white

or center) of direct wire cable under the center screw of the terminal block.

STEP 4a. Place the hook-shaped end

of the wire over the terminal block screw.

The open side of the hook should face to the right. Squeeze hook end of wire together to form a loop.

Hold-downscrew

Terminalblockcover

 

 

 

 

 

 

 

 

 

 

STEP 5. Connect the other two wires

 

 

 

to outer terminal block screws using the

 

 

 

same method(s) described in STEP 4a.

 

 

 

Tighten all terminal block screws firmly.

 

 

 

STEP 6. "lqghten the strain relief screws.

 

 

 

STEP 7. Insert tab of terminal block

 

 

 

cover into slot of the dryer rear panel.

 

 

 

Secure cover with hold-down screw.

 

 

 

If local codes do not permit the

STEP 3. Attach a 3/4-inch, U.L.-listed,

connection of a frame-grounding

conductor to the neutral wire, see

strain relief to the hole below terminal

the instructions on page 15.

block opening. Strain relief should have

Otherwise,

proceed

with Exhaust

a tight fit with

dryer cabinet and be in a

horizontal position. Put the direct wire

Installation.

See "CONNECT

EXHAUST"

on page

19.

cable through

the strain relief.

colored

Externalgroundterminal blockscrew

connector_

White neutral wire

Neutral grounding

wire (green/yell0w)

3/4",U.L-listed, strainrelief

3-Wire Connection with Direct Wire

and Frame-Grounding Conductor

14

Image 14
Contents OwnersManual Installation Instructions Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.AKeep this book and your Sears Your safety and the safety of others is very important Full 1-YEAR Warranty on Mechanical and Electrical PartsYour Safety is Important to US Parts Needed Installation OverviewSelect Location If making a direct wire connection Tools Needed Parts Needed Connect Exhaust pgs Tools Needed Parts Needed Optional dependingStandard Installation Select Location for Your DryerRecessed AREA/CLOSET Installation Instructions Product DimensionsInstall Leveling Legs Quincy, Massachusetts If Your Home Has Wire electrical ReceptacleIt is your responsibility Electrical Connection OptionsTHREE-WIREELECTRICAL NEIWire Connection with ConnectorWhite neutral wire Exlernal groundExhaust Alternateconnection Conductor to the neutral wireExternal Ground connector Electrical Connection to Receptacle III. Make FOUR-WIREFour-wire receptacle Nema Type 14-30R NeutralPowersupply WireGreenwire NeutralIV. FOUR-WIRE Electrical Connection Direct Wire Whiteneutralwire BarecopperwireNeutralTypical installations for left or right side exhausting Route the VentStep Determine Vent LengthExhaust Hood Type Ducttape & clamp Flexible metalventIDryer Periscope System Offset Connections with Close ClearancesLoop System Review Installation Final StepsYour Dryer Starting Your DryerSTOPPING/RESTARTING Timed DRY Cycle Cycle DescriptionAuto DRY Cycle Touch UP CycleFABRIC/TEMPERATURE Control Cottons and LinensAIR Fluff Using AIR DRY/AIR FluffTo use AIR Fluff Delicate FabricsPush to Start Button Cool DownLint Alert Using Wrinkle GuardWrinkleguard HEATEDDR.RACK Super Capacity Plus Dryers Preparing Clothes For DryingChoosing Load Sizes Using Dryer FABRICSOFrENERS Drying TipsInterior Cleaning Your DryerExterior Wash Lint Screen As Needed Cleaning the Lint ScreenTo clean To washRemoving Accumulated Lint Checking for AIR Flow ObstructionTo remove accumulated lint from Inside the dryer Vacation Care Changing the Drum LightMoving Care Not Drying Stains on Load ContLoad is overdried WrinkledKenmore Dryers We Service What We SellSears Maintenance Agreement For more information, callPage 8F,eLR8