and the neutral wire (white or center) of direct wire cable under the center screw
of terminal block.
Centersilver-colored terminal blockscrew
External ground | Whiteneutralwire |
connector |
|
BarecopperwireNeutral
grounding wire
;and
STEP 6. Place the
STEP 7. Connect the other two wires to outer terminal block screws. Use the same method described in STEP 6.
STEP 8. Connect the direct wire cable (bare) grounding wire to the external- grounding conductor screw. Tighten all terminal block screws firmly.
STEP 9. Tighten the strain relief screws.
STEP 10. Insert tab of terminal block
cover into slot of the dryer rear panel. Secure cover with
Proceed with Exhaust Installation. See "CONNECT EXHAUST" on this page.
D. CONNECT EXHAUST
A properly exhausted dryer will give you the shortest drying time, lower your utility bill, and extend the life of the dryer.
Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire.
•Replace plastic exhaust vent with heavy metal or flexible metal vent.
•Do not use
•Do not exhaust dryer into a chimney, furnace cold air duct, attic or crawl space, or any other duct used for venting.
°Do not install flexible metal vent in enclosed walls, ceilings, or floors,
•If using an existing exhaust system, disconnect vent from the dryer and
clean one section at a time until you reach the exhaust hood. To clean out
lint, you can use the hose attachment on your vacuum or, use a pole or wire with a feather duster or rag attached.
•Make sure exhaust hood is not plugged with lint. Follow the instructions in this
section to reinstall your vent system.
19