Kenmore 3405602 owner manual Select Location for Your Dryer, Standard Installation

Page 8

A. SELECT LOCATION FOR YOUR DRYER

Selecting the proper location

for your dryer makes installation easier and gives you the best drying performance.

STANDARD INSTALLATION

Check location where dryer will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation including proper floor support, a level floor, and a separate 30-amp. fuse.

*Protect dryer from the weather. Proper operation of dryer cycles requires temperatures above 45°F. At lower temperatures, the dryer may not shut cff at the end of automatic cycles. Drying times will be extended.

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches above the floor for a garage installation.

Failure to follow these instructions

can result in death, explosion, or fire.

Check code requirements. Some codes limit or do not permit installation of clothes dryers in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Separate

30-amp. fuse.

Grounded receptacle:

Within 2 feet of either

side of dryer.

Support:

Floor

must be

Level

floor: Maximum

allowable slope under entire

sturdy enough to support

dryer-

1 inch.

a total weight of 175

 

 

pounds

(includes

dryer

 

 

and load

weight).

 

 

 

y

Image 8
Contents OwnersManual Installation Instructions Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.AKeep this book and your Sears Your safety and the safety of others is very important Full 1-YEAR Warranty on Mechanical and Electrical PartsYour Safety is Important to US Parts Needed Installation OverviewSelect Location If making a direct wire connection Tools Needed Parts Needed Connect Exhaust pgs Tools Needed Parts Needed Optional dependingStandard Installation Select Location for Your DryerRecessed AREA/CLOSET Installation Instructions Product DimensionsInstall Leveling Legs If Your Home Has Wire electrical Receptacle It is your responsibilityQuincy, Massachusetts Electrical Connection OptionsTHREE-WIREELECTRICAL NEIConnector White neutral wireWire Connection with Exlernal groundExhaust Alternateconnection Conductor to the neutral wireExternal Ground connector III. Make FOUR-WIRE Four-wire receptacle Nema Type 14-30RElectrical Connection to Receptacle NeutralWire GreenwirePowersupply NeutralIV. FOUR-WIRE Electrical Connection Direct Wire Whiteneutralwire BarecopperwireNeutralTypical installations for left or right side exhausting Route the VentStep Determine Vent LengthExhaust Hood Type Ducttape & clamp Flexible metalventIDryer Periscope System Offset Connections with Close ClearancesLoop System Review Installation Final StepsYour Dryer Starting Your DryerSTOPPING/RESTARTING Cycle Description Auto DRY CycleTimed DRY Cycle Touch UP CycleFABRIC/TEMPERATURE Control Cottons and LinensUsing AIR DRY/AIR Fluff To use AIR FluffAIR Fluff Delicate FabricsPush to Start Button Cool DownLint Alert Using Wrinkle GuardWrinkleguard HEATEDDR.RACK Super Capacity Plus Dryers Preparing Clothes For DryingChoosing Load Sizes Using Dryer FABRICSOFrENERS Drying TipsInterior Cleaning Your DryerExterior Cleaning the Lint Screen To cleanWash Lint Screen As Needed To washRemoving Accumulated Lint Checking for AIR Flow ObstructionTo remove accumulated lint from Inside the dryer Vacation Care Changing the Drum LightMoving Care Not Drying Cont Load is overdriedStains on Load WrinkledWe Service What We Sell Sears Maintenance AgreementKenmore Dryers For more information, callPage 8F,eLR8