5.Use the handle to pull the heat exchanger out of the base and carry it horizontally to prevent any remaining water from spilling.
6.To empty the heat exchanger, hold verti- cally over a
Caution! Do not use sharp objects to clean. The heat exchanger could develop leaks.
7.Clean heat exchanger.
It is best to use a brush or to rinse thor- oughly with a
8.Replace heat exchanger and lock into place (turn both lock washers outwards until they snap into place).
9.Close door in plinth.
The appliance will not operate if the HEAT EXCHANGER indicator is still lit.
Caution! Never operate the dryer without the heat exchanger.
Cleaning the drum
Caution! Do not use abrasives or steel wool to clean the drum.
Lime in the water or cleaning agents may form a barely visible lining on the inside of the drum. The degree to which the laundry has been dried is then no longer detected reliably. The laundry is damper than expected when removed from the appliance.
Use a standard domestic cleaner (e.g. vine-
Clean control panel and housing
Caution! Do not use furniture cleaners or aggressive cleaning agents to clean the machine.
Use a damp cloth to wipe down the control panel and housing.
What to do if ...
Troubleshooting by yourself
If during operation, the error code E plus number or letter) appears on the
Reset programme. Press the START/PAUSE button. If the error appears again, please contact the Customer Care Department, stating the error code
Problem
Dryer does not work.
IronAid programme does
not start. the water tank indicator lights up.
Possible cause
Mains plug is not plugged in or fuse is not working correctly.
Loading door is open.
Have you pressed the START/ PAUSE button?
Water tank is empty.
Recirculation valve is closed (OFF position)
Remedy
Plug in at mains socket. Check fuse in fuse box (domestic installation).
Close loading door.
Press the START/PAUSE button again.
Fill water tank.
Turn the recirculation valve to ON position.