NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within

6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 9.

1

5

2

3

4

D233I

D233I

1New stainless steel flexible connector – (Use design CSA certified connector) Use only if allowed by local codes

21/8 in. NPT Pipe Plug

3Equipment Shut Off Valve

4Black Iron Pipe

Shorter than 20 ft. (6.1 m) – Use 3/8 in. (9.5 mm) pipe. Longer than 20 ft. (6.1 m) – Use 1/2 in. (12.7 mm) pipe.

53/8 in. NPT Gas Connection

Figure 9

4.Tighten all connections securely. Turn on gas and check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid.

NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). Refer to Step 9 (Check Heat Source).

L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft3

(93.1 MJ/m3) service must be supplied at 10 ± 1.5 inch water column pressure.

For proper operation at altitudes above 3500 feet

(1070 m) the L.P. gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 3.

 

 

 

 

 

 

Installation

 

 

 

 

 

L.P. Altitude Adjustments

 

 

Altitude

 

Orifice Size

 

 

Part

feet

m

No.

inches

 

mm

 

No.

3500

1070

54

0.0550

 

1.40

 

503785

7500

2290

55

0.0520

 

1.32

 

58755

11000

3355

56

0.0465

 

1.18

 

503786

Table 3

NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. Install L.P. Gas Conversion Kit 458P3, available at extra cost.

Step 4: (Electric Dryer Only) Connect Electrical Plug

Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4 wire electrical suppy. Refer to serial plate for specific electrical requirements.

NOTE: The wiring diagram is located inside the control hood.

WARNING

To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer’s responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer.

W521

Grounding Information

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The cord-kit must be equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

513005

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

15

Image 17
Contents Clothes Dryer Page What to do if YOU Smell GAS Contents Important Safety Instructions Safety InformationExplanation of Safety Messages Safety Information Metered Models InstallationDimensions Tools Before You StartPosition and Level the Dryer Installing the DryerArea Description Free Standing/Alcove Closet Installation Connect Dryer Exhaust System Exhaust Direction ∙ Failure to exhaust dryer properly will void warrantyMaximum length of 4 in .2 cm diameter rigid metal duct Exhaust SystemMulti-Dryer Installation Exhaust Requirements Roof No Screen or Cap Wall Cm Minimum Gas Dryer Only Connect Gas Supply Pipe Installation Duct Station Minimum Diameter Collector DuctGrounding Information Electric Dryer Only Connect Electrical PlugWire Length Typical Receptacle SHUT-OFF BOX Connecting Power Cord with Three-Wire PlugConnecting Power Cord with Four-Wire Plug D695I Reverse Door, if Desired Reinstall nine screws removed in StepPlug In the Dryer Wipe Out Inside of DryerElectric Dryer Gas DryerPlug cord into separately fused Check Heat Source Recheck StepsElectric Dryers Gas DryersAdditional Dryer Security VendingMeter Case Operation Clean Lint FilterOperation Instructions Load LaundryTo Insert Card Set Fabric SelectorInsert Coins or Card To Insert MoneyStart Dryer Indicator LightsCare of Your Dryer MaintenanceLubrication For Energy Conservation Lint FilterMotor Overload Protector Dryer Symptom Possible Cause/Solution Dryer won’t start TroubleshootingAlliance Laundry Systems Shepard Street Box Ripon, WI Contact InformationPage Fast Track for Installing the Dryer Installer Checklist