Alliance Laundry Systems DRY710C manual Exhaust System

Page 13

Installation

Exhaust System

For best drying results, recommended maximum length of exhaust system is shown in Table 1.

To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).

NOTE: Weather hood should be installed at least 12 inches (30.5 cm) above the ground. Larger clearances may be necessary for installations where heavy snowfall can occur.

Number of

 

Weather Hood Type

90° Elbows

Recommended

 

Use Only for Short Run installations

 

4 in.

4 in.

2-1/2 in.

 

(10.2 cm)

(10.2 cm)

 

 

 

(6.35 cm)

 

 

D673I

D802I

Maximum length of 4 in. (10.2 cm) diameter rigid metal duct.

0

1

2

3

4

65 feet (19.8 m)

55 feet (16.8 m)

55 feet (16.8 m)

47 feet (14.3 m)

47 feet (14.3 m)

41 feet (12.5 m)

36 feet (11.0 m)

30 feet (9.1 m)

28 feet (8.5 m)

22 feet (6.7 m)

 

 

NOTE: Deduct 6 feet (1.8 m) for each additional elbow.

Table 1

NOTE: The maximum length of a 4 in. (10.2 cm) diameter flexible metal duct must not exceed

7.87ft. (2.4 m), as required to meet UL2158, clause 7.3.2A.

513005

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

11

Image 13
Contents Clothes Dryer Page What to do if YOU Smell GAS Contents Explanation of Safety Messages Safety InformationImportant Safety Instructions Safety Information Dimensions InstallationMetered Models Tools Before You StartPosition and Level the Dryer Installing the DryerArea Description Free Standing/Alcove Closet Installation Connect Dryer Exhaust System Exhaust Direction ∙ Failure to exhaust dryer properly will void warrantyMaximum length of 4 in .2 cm diameter rigid metal duct Exhaust SystemMulti-Dryer Installation Exhaust Requirements Roof No Screen or Cap Wall Cm Minimum Gas Dryer Only Connect Gas Supply Pipe Installation Duct Station Minimum Diameter Collector DuctGrounding Information Electric Dryer Only Connect Electrical PlugWire Length Typical Receptacle SHUT-OFF BOX Connecting Power Cord with Three-Wire PlugConnecting Power Cord with Four-Wire Plug D695I Reverse Door, if Desired Reinstall nine screws removed in StepPlug In the Dryer Wipe Out Inside of DryerElectric Dryer Gas DryerPlug cord into separately fused Check Heat Source Recheck StepsElectric Dryers Gas DryersMeter Case VendingAdditional Dryer Security Operation Clean Lint FilterOperation Instructions Load LaundryTo Insert Card Set Fabric SelectorInsert Coins or Card To Insert MoneyStart Dryer Indicator LightsLubrication MaintenanceCare of Your Dryer Motor Overload Protector Lint FilterFor Energy Conservation Dryer Symptom Possible Cause/Solution Dryer won’t start TroubleshootingAlliance Laundry Systems Shepard Street Box Ripon, WI Contact InformationPage Fast Track for Installing the Dryer Installer Checklist