Installation

WARNING

Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded.

W038

Do not modify the plug provided with the cord-kit - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). Electrical service for the dryer should be of maximum rated voltage (208 or 240 Volt, depending on heating element) listed on the nameplate. Do not connect dryer to 110, 115, or 120 Volt circuit.

Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate, such as 208 Volt.

NOTE: Branch circuit wire size requirements to laundry room outlet are shown in Table 4.

Wire Length

 

Wire

Less than

 

Listed No. 10 AWG

15 ft. (4.5 m)

 

Copper wire only

 

 

 

Longer than

 

Listed No. 8 AWG

15 ft.(4.5 m)

 

Copper wire only

 

Table 4

The power cord connection between wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of power cord and gauge of wire must conform to local codes.

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

513005

Image 18
Contents Clothes Dryer Page What to do if YOU Smell GAS Contents Safety Information Explanation of Safety MessagesImportant Safety Instructions Safety Information Installation DimensionsMetered Models Before You Start ToolsInstalling the Dryer Position and Level the DryerArea Description Free Standing/Alcove Closet Installation Connect Dryer Exhaust System ∙ Failure to exhaust dryer properly will void warranty Exhaust DirectionExhaust System Maximum length of 4 in .2 cm diameter rigid metal ductMulti-Dryer Installation Exhaust Requirements Roof No Screen or Cap Wall Cm Minimum Installation Duct Station Minimum Diameter Collector Duct Gas Dryer Only Connect Gas Supply PipeElectric Dryer Only Connect Electrical Plug Grounding InformationWire Length Typical Receptacle Connecting Power Cord with Three-Wire Plug SHUT-OFF BOXConnecting Power Cord with Four-Wire Plug D695I Reinstall nine screws removed in Step Reverse Door, if DesiredElectric Dryer Wipe Out Inside of DryerPlug In the Dryer Gas DryerPlug cord into separately fused Electric Dryers Recheck StepsCheck Heat Source Gas DryersVending Meter CaseAdditional Dryer Security Operation Instructions Clean Lint FilterOperation Load LaundryInsert Coins or Card Set Fabric SelectorTo Insert Card To Insert MoneyIndicator Lights Start DryerMaintenance LubricationCare of Your Dryer Lint Filter Motor Overload ProtectorFor Energy Conservation Troubleshooting Dryer Symptom Possible Cause/Solution Dryer won’t startContact Information Alliance Laundry Systems Shepard Street Box Ripon, WIPage Installer Checklist Fast Track for Installing the Dryer