ADC AD-115ES installation manual Type of GAS

Page 27

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

TYPE OF GAS

 

Liquid

 

 

 

 

 

 

 

 

 

Propane

 

 

 

Natural

 

 

Liquid Propane

Btu/hr

kcal/hr

 

 

 

Conversion Kit

Rating

Rating

Qty.

D.M.S.*

 

Part No.

Qty.

D.M.S.*

Part No.

Part Number

343,000

86,436

3

#8

 

140837

3

#31

140818

880876

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#8 =

0.1990” (5.0546 mm).

Liquid Propane Gas

#31 =

0.1200” (3.048 mm).

3.Piping and Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance Btu being supplied.

The dryer is provided with a 1” N.P.T. inlet pipe connection extending out the back area of the burner box. The minimum pipe size connection (supply line) to the dryer is 1” diameter. For ease of servicing, the gas supply line of each dryer must have its own shutoff valve.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same supply line, etc. Specific information regarding supply line size should be determined by the gas supplier.

NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.

Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1-inch (2.54 cm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pressure.

IMPORTANT: A water column pressure of 3.5 inches (8.7 mb) for natural gas and 10.5 inches (26.1 mb) for L.P. dryers is required at the gas valve pressure tap of each dryer for proper and safe operation.

113202 - 10

www.amdry.com

23

Image 27
Contents AD-115ES Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Safety PrecautionsStandard Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Gas, Electric, and Steam Component Identification 113202 Location Requirements Installation ProceduresUnpacking and Setting UP American Dryer Corp 113202 This Exhaust Duct Transition Piece Must be Installed First Fresh AIR Supply Requirements Dryer Enclosure RequirementsGeneral Exhaust Ductwork Information Exhaust RequirementsAmerican Dryer Corp 113202 Outside Ductwork Protection American Dryer Corp 113202 Electrical Information Reversing, 3ø Motor Gas and Steam Reversing, 3ø Motor Electric American Dryer Corp 113202 GAS Information Type of GAS Type of GAS American Dryer Corp 113202 Steam Information Operating Steam PressureCompressed Air Supply Air Pressure Steam Damper System113202 Before YOU Start Check Local Codes and Permits Water Information113202 Typical Water Supply Preparation for Operation and START-UP Preoperational Test Basket Tumbler Coating Preoperational Instructions Dual Timer DryersShutdown Instructions Reversing Timer SPIN/DWELL AdjustmentsSERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyAmerican Dryer Corp 113202 Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsData Label Information Procedure for Functional Check Replacement Components 113202 Manual Reset Burner HI-LIMIT Instructions PhaseDual Timer 113202 ADC Part No 10 12/10/08