ADC AD-115ES installation manual Adjustments, Lubrication

Page 44

90 DAYS

Remove lint from around basket (tumbler), drive motors, and surrounding areas.

Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment. Clean any lint that may have collected in and around the blower motor casing openings.

IMPORTANT: To prevent damage, avoid cleaning or touching ignitor and flame-probe assembly.

Remove lint accumulation from inside the control box and at the rear area behind the control box.

Impellor (fan/blower) shaft bearings should be lubricated using Shell Alvania #2 grease or its equivalent. Generically, this grease would be described as an NLGI grade 2 multipurpose industrial with a lithium thickener and mineral base oil.

6 MONTHS

Inspect and remove lint accumulation in customer-furnished exhaust ductwork system and from dryer’s internal exhaust ducting.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK COULD CREATE AFIRE HAZARD.

WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR. CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN EXHAUST DUCTWORK. INSPECTAND REMOVE ANY LINT ACCUMULATION, WHICH CAN CAUSE DAMPER TO BIND OR STICK.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats.

NOTE: When cleaning the dryer cabinets, avoid using harsh abrasives. Aproduct intended for the cleaning of appliances is recommended.

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing setscrews), grounding connections, and nonpermanent gas connections (unions, shutoff valves, and orifices). Motor and drive belts should be examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete operational check of ALL safety devices (door switch, lint drawer switch, sail switch, burner, and hi-limit thermostats).

C. LUBRICATION

The motor bearings, and under normal/most conditions the basket (tumbler) and idler bearings, are permanently lubricated. It is physically possible to relubricate the basket (tumbler) bearings if you choose to do so even though this practice may not be necessary. Use Shell Alvania #2 or its equivalent. The basket (tumbler) bearings used in the dryer DO NOT have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting, which can be obtained elsewhere.

40

American Dryer Corp.

113202 - 10

Image 44
Contents AD-115ES Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Safety Precautions SectionStandard SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Gas, Electric, and Steam Component Identification 113202 Installation Procedures Location RequirementsUnpacking and Setting UP American Dryer Corp 113202 This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply RequirementsExhaust Requirements General Exhaust Ductwork InformationAmerican Dryer Corp 113202 Outside Ductwork Protection American Dryer Corp 113202 Electrical Information Reversing, 3ø Motor Gas and Steam Reversing, 3ø Motor Electric American Dryer Corp 113202 GAS Information Type of GAS Type of GAS American Dryer Corp 113202 Operating Steam Pressure Steam InformationSteam Damper System Compressed Air Supply Air Pressure113202 Water Information Before YOU Start Check Local Codes and Permits113202 Typical Water Supply Preparation for Operation and START-UP Preoperational Test Basket Tumbler Coating Dual Timer Dryers Preoperational InstructionsReversing Timer SPIN/DWELL Adjustments Shutdown InstructionsParts SERVICE/PARTS InformationService Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsAmerican Dryer Corp 113202 Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationData Label Information Procedure for Functional Check Replacement Components 113202 Dual Timer Manual Reset Burner HI-LIMIT InstructionsPhase 113202 ADC Part No 10 12/10/08