ADDITIONAL INSTRUCTIONS FOR EXPORT MODELS
(Not U.S. Mexico, or Canada) Contact the distributor that sold the appliance or: Amana International,
1475 East Woodfield Road Schaumburg, Illinois 60173 Phone:
Amana dryer models manufactured for operation on 60Hz AC are not designed for use on 50Hz AC electrical service and conversion of the product from 60 to 50Hz operation is not recommended. For additional information on 50Hz product, contact Amana International. The electric service reqirements can be found on the data label located on the front of the dryer behind the door.
EXPORT ELECTRIC MODELS
Some export electric models are manufactured for operation on 230/240 volt, 50 Hz and some for operation on 220 Volt, 60 Hz electric service. A
IMPORTANT: When permitted by local codes the dryer electrical supply may be connected by means of a power supply cord kit. The cord must marked for use with clothes dryers, agency listed, rated for 240 volts - 30 amp minimum. The cord should be terminated with closed loop terminals,
2-WIRE SYSTEM CONNECTIONS
1.Loosen or remove center terminal block screw.
2.Connect neutral wire (White or center wire) of power supply cord to the center, silver colored terminal screw of the terminal block. Tighten screw.
3.Connect the other wire to outer terminal block serew. Tighten screw.
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel, Sccure cover with
1. External ground connector
2. Neutral grounding wire (green.yellow)
3. Center
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 c m )
6. Neutral wire (white or center wire)
BEFORE OPERATING OR TESTING, be sure the machine is properly grounded.
EXPORT GAS MODELS
Some export gas models are manufactured for operation on 230/240 volt, 50 Hz and some for operation on 220 volt, 60 Hz electrical service with a 15 amp fuse or circuit breaker.
Export gas models have been manufactured for use with natural gas having a higher heating value of approximately 1025 BTU per cubic foot. Conversion to LP gas with a higher heating value must be performed by a qualified service technician. A 33002927 Natural Gas to LP Gas, 50 Hz conversion kit is available.
12