American Dryer Corp ML-122D Procedure for Functional Check Replacement Components

Page 48

SECTION VIII

PROCEDURE FOR FUNCTIONAL CHECK

OF REPLACEMENT COMPONENTS

1.Microprocessor Controller (Computer) Board

a.Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer.

b.Start the drying cycle by pressing any of the preset cycles in letters A-F.

c.Verify that the motor(s) and the heat indicator dots, in the microprocessor controller (computer) light emittingdiode(L.E.D.)displayareon. (Refertothe illustration below.)

1)Basket (tumbler) in Forward Mode (clockwise [CW]) indicator

2)Basket (tumbler) in Reverse Mode (counterclockwise [CCW]) indicator

3)Heat On indicator

4)On indicator (dryer is in Operation Mode)

5)Air Jet indicator

44

Image 48
Contents ML-122D Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification Specifications GAS and SteamSpecifications MLG-122 Gas MLS-122 Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Lift the console module off the dryer base C Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Electrical Information Electrical RequirementsML-122 Gas and Steam Only Page GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationPage Compressed AIR Pressure AIR Supply Page Compressed AIR Preparation for OPERATION/START-UPPreoperational Tests Inches 26.1 mb water column Basket Coating Operating Instructions Shut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationReversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Page Page Page Data Label Information Data LabelSerial Number For Phase 6 Models ADC 02/16/00-15 11/10/00-10 08/13/01-25