American Dryer Corp AD-115ES II installation manual

Page 41

6.Steam Damper Air Piston (Air Control) Operation Adjustment

Although the damper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bar), steam damper operation must be checked before the dryer is put into operation. Refer to page 36 for instructions to check system damper system operation. If damper air adjustment is necessary, locate the flow control valve and make the necessary adjustments as noted below.

37

Image 41
Contents AD-115ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Gas Models Only Electric or Steam Models Only Cleaning Adjustments LubricationData Label Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandard Specifications SPECIFICATIONS/COMPONENT IdentificationPage Component Identification Page Location Requirements Installation ProceduresUnpacking and Setting UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Page Page Page Page Page Page Electrical Information Electrical Service Specifications PER Dryer ADE-115ES 60 Kw Electric Oven Reversing, 3ø Motor ADE-115ES 72 Kw Electric Oven Reversing, 3ø Motor Page Page GAS Information 27.4 mb 26.1 mbPage Page 170.1 kg/hr Steam Information 689 kPa Page Compressed AIR AIR Pressure Supply Page Preparation for Operation and START-UP Preoperational Tests Page Basket Tumbler Coating Shutdown InstructionsParts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Clean the lint drawer or screen every third or fourth loadSteam Dryers Lubrication AdjustmentsDrive motor is not operating does not start TroubleshootingNo light emitting diode L.E.D. display Blower motor is not operating does not start Microprocessor controller computer display reads door Microprocessor controller computer display reads dSFLFailed microprocessor controller computer No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise or vibration Dryer is making scraping noise at basket tumbler areaData Label Data Label InformationSerial Number Timing Legend Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Page P O R T a N T ADC P/N114501