e.Open main door. The dryer must stop and ALL indicator lights on the back side of the microprocessor controller (computer) board must go out. (Refer to the illustration on the previous page.)

f.Try to restart the dryer with the main door open.

g.The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must read “DOOR.”

h.Close the main door and restart the dryer.

i.Functional check of microprocessor controller (computer) board is complete.

2.For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760) Theory Of Operation:

Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open...as long as there is a call for heat. The DSI module will “LOCKOUT” if the gas burner flame is not sensed at the end of the trial for ignition period. The trial for ignition period will be repeated for a total of three (3) retries/trials (the initial try and two [2] more retries/trials). If the flame is not sensed at the end of the third retry/trial (inter-purge period of 30-seconds) the DSI module will “LOCKOUT” (L.E.D. flashes).

A steady L.E.D. indicator indicates normal operation.

No L.E.D. indicator indicates a power or an internal failure has occurred.

59

Image 63
Contents AD-115ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Cleaning Adjustments Lubrication Data LabelGas Models Only Electric or Steam Models Only Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandard Specifications SPECIFICATIONS/COMPONENT IdentificationPage Component Identification Page Location Requirements Installation ProceduresUnpacking and Setting UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Page Page Page Page Page Page Electrical Information Electrical Service Specifications PER Dryer ADE-115ES 60 Kw Electric Oven Reversing, 3ø Motor ADE-115ES 72 Kw Electric Oven Reversing, 3ø Motor Page Page GAS Information 27.4 mb 26.1 mbPage Page Steam Information 689 kPa170.1 kg/hr Page Compressed AIR AIR Pressure Supply Page Preparation for Operation and START-UP Preoperational Tests Page Basket Tumbler Coating Shutdown InstructionsSERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Clean the lint drawer or screen every third or fourth load Routine MaintenanceCleaning Suggested Cleaning ScheduleSteam Dryers Lubrication AdjustmentsTroubleshooting No light emitting diode L.E.D. displayDrive motor is not operating does not start Blower motor is not operating does not start Microprocessor controller computer display reads door Microprocessor controller computer display reads dSFLFailed microprocessor controller computer No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise or vibration Dryer is making scraping noise at basket tumbler areaData Label Data Label InformationSerial Number Timing Legend Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Page P O R T a N T ADC P/N114501