American Dryer Corp AD-115ES II Timing Legend, Reversing Timer SPIN/DWELLADJUSTMENTS

Page 61

SECTION IX

REVERSING TIMER SPIN/DWELLADJUSTMENTS

Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is located in the upper rear area of the dryer.

Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

 

 

 

 

 

 

DWELL (STOP) TIME

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

5

6.3

7.6

8.9

10.2

 

 

 

 

 

 

* Values shown are +/- 1-second.

57

Image 61
Contents AD-115ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Data Label Cleaning Adjustments LubricationGas Models Only Electric or Steam Models Only Receiving and Handling Important InformationWhat to do if YOU Smell GAS Safety PrecautionsStandard Specifications SPECIFICATIONS/COMPONENT IdentificationPage Component Identification Page Location Requirements Installation ProceduresUnpacking and Setting UP Page This Exhaust Duct Transition Piece Must be Installed First Dryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust RequirementsPage Page Page Page Page Page Page Electrical Information Electrical Service Specifications PER Dryer ADE-115ES 60 Kw Electric Oven Reversing, 3ø Motor ADE-115ES 72 Kw Electric Oven Reversing, 3ø Motor Page Page GAS Information 27.4 mb 26.1 mbPage Page 689 kPa Steam Information170.1 kg/hr Page Compressed AIR AIR Pressure Supply Page Preparation for Operation and START-UP Preoperational Tests Page Basket Tumbler Coating Shutdown InstructionsService SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceSuggested Cleaning Schedule Clean the lint drawer or screen every third or fourth loadSteam Dryers Lubrication AdjustmentsNo light emitting diode L.E.D. display TroubleshootingDrive motor is not operating does not start Blower motor is not operating does not start Microprocessor controller computer display reads door Microprocessor controller computer display reads dSFLFailed microprocessor controller computer No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise or vibration Dryer is making scraping noise at basket tumbler areaData Label Data Label InformationSerial Number Timing Legend Reversing Timer SPIN/DWELLADJUSTMENTSProcedure for Functional Check Replacement Components Page Page P O R T a N T ADC P/N114501