D E C 2012 | DANIELTM MODEL 788DVC DIGITAL CONTROL VALVES |
NCC 12.1244 X
Ex d nC IIB T3 Gc
Ex d IIC T* Gb
*See Tables 1 and 2 in the certificate for temperature range details.
Special condition for safe use: When the digital control valve is assembled with solenoid models 80174, 80173, 80143, 80144, HP80143, 8014G2 and F8003G1, the temperature of the process fluid must not be greater than 40°C.
Connections
2" through 6" ANSI flanged
Valve Capacity
Valve Size | 2" | 3" | 4" | 6" | 8" |
Cv* - gpm | 86 | 186 | 309 | 688 | 1296 |
*Cv based on valve full open using water at 60/F (16/C)
For Valve Flow vs. Pressure Loss see Figure
Flow vs. Pressure Drop (See Figure 3-1)
Curve A - Wide open valves with no spring resistance.
Applicable to pilot operated valves with Y and Z ports vented to sump, atmosphere or pump station.
Curve B - Light main valve spring.
Applies only to
Curve C - Medium main valve spring.
Applies to all modulating control valves except rate of flow and valves using ANSI 600 lb. flanges.
Curve D- Heavy main valve spring.
Applies to all valves using ANSI 600 lb. flanges.
SPECIFICATIONS |