Emerson 788 DVC manual Recommended Low Flow Set-point

Page 33

DANIELTM MODEL 788DVC DIGITAL CONTROL VALVES

D E C 2012

6.Lift off the cylinder head by taking out the socket screws.

7.Remove and inspect all O-rings for nicks, cuts and wear.

Figure 5-1. Using the Piston to Insert the Seat Ring into the 150/300 lb. Cylinder

Table 5-l. Typical Opening/Closing Speed

 

Typical

Recommended Low Flow Set-point

Typical

Typical

Typical

Typical

Line

Dead

 

 

 

 

Opening

Opening

Closing

Closing

Size

Time

 

Turbine

PD Meter

Speed

Time

Speed

Time

Inches

Setting

 

Adjust-

(Shut-off

Adjust-

(Full

 

 

 

 

 

(Seconds)

 

 

 

 

ment

to Full

ment

Open to

 

 

gpm

K-factor

gpm

K-factor

(Turns

Open)

(Turns

Shut-off)

 

 

 

 

 

 

Open)

Seconds

Open)

Seconds

2-3

0.015

100

50

100

100

0.25

5.0

0.75

2.0

4

0.015

150

25

150

25

0.25

5.0

0.75

2.0

6

0.030

150

25

150

25

0.75

5.0

1.25

2.0

8

0.030

150

25

150

25

0.75

5.0

1.25

2.0

DISASSEMBLY AND REASSEMBLY

5-3

Image 33
Contents DanielTM Model 788 DVC digital control valves This page intentionally left blank Important safety instructions Product operation personnel Safety alert symbol Safety signal words and symbolsThis page intentionally left blank Page Warranty and limitation of liability Introduction Tables FiguresAggressive Products Danieltm Model 788DVC Digital Control Valves IntroductionEquipment Damage Principle of OperationOperational Sequence Closed Position Open Control Position Open Position no control Safe Working Temperature Ranges Do not exceed specifications listed belowPressure Class Maximum Safe Working PressureConnections Valve CapacityFlow vs. Pressure Drop See Figure Flow vs Pressure Loss Materials of Construction Main Valve Body Pressure/Temperature RatingsCylinder Head Main Valve CylinderTubing Astm A352 LCC WCB Dimensions Valve Size 150# Ansi 300# Ansi No Indicator With Indicator Recommended Installation Instructions General Considerations as Applied to the DL8000 Use equipment for its intended purpose Personal Injury or Death AND/OR Property DamageTypical Application Top Loading Typical Application Bottom Loading Control Valve Configuration new for DL8000 Cylinder Assembly Removal All Daniel Valves Cylinder Disassembly Recommended Low Flow Set-point Cylinder Reassembly Retrofit Cup-seal Replacement on Existing AP Option PistonOption Assembly Danieltm Model 788DVC Digital Control Valves Personal Injury AND/OR Equipment Damage Danieltm Model 788DVC Digital Control Valves Troubleshooting Condition Probable Cause Correction Danieltm Model 788DVC Digital Control Valves Parts List Parts List 2, 3, 4, 6, 8 Sizes Recommended Spare Parts Valve Cylinder Assembly Infectious Radioactive Explosive Pyrophoric Poison Gas Decontamination/Cleaning Fluids ProcessShipping Requirements Page W .em erson.com