5. Connecting to the bus

bConnection cables for the master

Type of master

Master interface

Description

Catalog number

Twido PLC

Adaptor or mini-DIN

3 m cable equipped with a mini-DIN connector and an RJ45

TWD XCA RJ030

 

RS485 interface module

connector

 

 

 

 

 

 

Adaptor or screw

3 m cable equipped with an RJ45 connector and stripped at

VW3 A8 306 D30

 

terminal RS485

the other end

 

 

interface module

 

 

 

 

 

 

TSX Micro PLC

Mini-DIN RS485

3 m cable equipped with a mini-DIN connector and an RJ45

TWD XCA RJ030

 

connector port

connector

 

 

 

 

 

 

PCMCIA card

Stripped cable

TSX SCP CM 4030

 

(TSX SCP114)

 

 

 

 

 

 

TSX Premium PLC

TSX SCY 11601 or

Cable equipped with a 25-way SUB-D connector and

TSX SCY CM 6030

 

TSX SCY 21601

stripped at the other end (for connection to the screw

 

 

module

terminals of the LU9GC3 splitter block)

 

 

(25-way SUB-D socket)

 

 

 

 

 

 

 

PCMCIA card

Stripped cable

TSX SCP CM 4030

 

(TSX SCP114)

 

 

 

 

 

 

Ethernet bridge

Screw terminal RS485

3 m cable equipped with an RJ45 connector and stripped at

VW3 A8 306 D30

(174 CEV 300 20)

 

the other end

 

 

 

 

 

Profibus DP gateway

RJ45 RS485

1 m cable equipped with 2 RJ45 connectors

VW3 P07 306 R10

(LA9P307)

 

 

 

 

 

 

 

Fipio (LUFP1) or

RJ45 RS485

0.3 m cable equipped with 2 RJ45 connectors or

VW3 A8 306 R03 or

Profibus DP (LUFP7) or

 

1 m cable equipped with 2 RJ45 connectors or

VW3 A8 306 R10 or

DeviceNet (LUFP9)

 

3 m cable equipped with 2 RJ45 connectors

VW3 A8 306 R30

gateway

 

 

 

 

 

 

 

Serial port PC

Male 9-way SUB-D

RS232/RS485 converter and 3 m cable equipped with an

TSX SCA 72 and

 

RS232 serial port PC

RJ45 connector and stripped at the other end (for

VW3 A8 306 D30

 

 

connection to the screw terminals of the LU9GC3 splitter

 

 

 

block)

 

 

 

 

 

11

Image 11
Contents Altivar Contents Electric shock will result in death or serious injury Before you beginCommunication Parameters Manual Installation ManualDocumentation structure Programming ManualNotation IntroductionPresentation Hardware description Hardware setupInstalling the card in the drive ReceiptCoding the address Switch codingChoosing polarization 1234 AddressModbus RS485 standard Connecting to the busWiring recommendations Connection cables Connection via RJ45 wiring systemConnection accessories TSX SCP CM Connection cables for the masterType of master Master interface Description Catalog number TWD XCA RJ030Cables Connection via junction boxesDescription Catalog Number Subscriber socket RS485 double shielded twisted pairTSX P ACC TSX CSA500Communication parameters ConfigurationParameter Value Comment Control CommandControl via Modbus in I/O profile Control via Modbus or the terminals in I/O profileControl via Modbus or the terminals in Drivecom profile Control via Modbus in Drivecom profileConfiguration COM. Scanner Input Example of configuration via the graphic display terminalCommunication scanner RDY NETCOM. Fault Management Communication faultsFormat Range Terminal display CONFIG. COMM. MAPMonitored parameters FormatGreen RUN Red ERR Meaning Corrective action DiagnosticsChecking the address LEDsCOM Scan Output MAP CMD. Word Image RUN NETCommunication MAP COM. Scanner Input MAPCOM Scan Output MAP Input variable Scanner parameterOutput variable Scanner parameter Card fault Communication faultSlave Slave j Slave k Modbus protocolPrinciple Slave address Function code Data RTU modeAscii mode ModesCode Modbus name Description Broadcast Size of data Modbus functions availableRead Holding/Input Registers 3/4 Write Single Register Diagnostics Write Multiple Registers 16 = 16#10 Get Comm Event Counter 11 = 16#0BRead/Write Multiple Registers 23 = 16#17 Machine Read Device Identification 43 = 16#2BMEI Example of positive responseCode Modbus name Description Size of data Output variables Logic address Default assignmentInput variables Logic address Default assignment Parameter Logic Input variable address Logic address Default valueParameter Logic Read Value Parameter assigned Output controlParameter assigned Input monitoringResponse Code Error codeException responses Logic address Parameter Value Read non-existent or protected parametersRS485 standard AppendixMaster Modbus 2-wire standard schematicModbus 4-wire standard schematic Uni-Telway schematic Type of trunk cable Cable with 1 shielded twisted pair Wire Jbus schematicRecommendations Creating a Modbus bus using non-standard equipmentDifferent scenarios Example Calculating the polarizationSUB-D RS485 schematic for the cardCard connector pinout Contact no. SignalAtv71ModbusJbusENV1 2005-05