Schneider Electric VW3 A3 303 user manual TSX CSA500, Tsx P Acc

Page 13

5. Connecting to the bus

bConnection cables for the master

Type of master

Master interface

Description

Catalog number

Twido PLC

Adaptor or screw terminal

Modbus cable

TSX CSA100 or

 

RS485 interface module

 

TSX CSA200 or

 

 

 

TSX CSA500

 

 

 

 

TSX Micro PLC

Mini-DIN RS485

Tap junction

TSX P ACC 01

 

connector port

 

 

 

 

 

 

 

PCMCIA card (TSX SCP114)

Cable equipped with a special connector and

TSX SCP CM 4030

 

 

stripped at the other end

 

TSX Premium PLC

TSX SCY 11601 or

 

TSX SCY 21601 module

 

(25-way SUB-D socket)

Cable equipped with a 25-way SUB-D

TSX SCY CM 6030

connector and stripped at the other end

 

 

PCMCIA card (TSX SCP114)

Cable equipped with a special connector and

TSX SCP CM 4030

 

 

stripped at the other end

 

 

 

 

 

Ethernet bridge

Screw terminal RS485

Modbus cable

TSX CSA100 or

(174 CEV 300 10)

 

 

TSX CSA200 or

 

 

 

TSX CSA500

 

 

 

 

Profibus DP gateway

RJ45 RS485

3 m cable equipped with an RJ45 connector

VW3 A8 306 D30

(LA9P307)

 

and stripped at the other end

 

 

 

 

 

Fipio (LUFP1) or

RJ45 RS485

3 m cable equipped with an RJ45 connector

VW3 A8 306 D30

Profibus DP (LUFP7) or

 

and stripped at the other end

 

DeviceNet (LUFP9) gateway

 

 

 

 

 

 

 

Serial port PC

Male 9-way SUB-D RS232

RS232/RS485 converter and

TSX SCA 72 and

 

serial port PC

Modbus cable

TSX CSA100 or

 

 

 

TSX CSA200 or

 

 

 

TSX CSA500

 

 

 

 

13

Image 13
Contents Altivar Contents Electric shock will result in death or serious injury Before you beginDocumentation structure Installation ManualProgramming Manual Communication Parameters ManualPresentation IntroductionNotation Installing the card in the drive Hardware setupReceipt Hardware descriptionChoosing polarization Switch codingCoding the address 1234 AddressWiring recommendations Connecting to the busModbus RS485 standard Connection accessories Connection via RJ45 wiring systemConnection cables Type of master Master interface Description Catalog number Connection cables for the masterTWD XCA RJ030 TSX SCP CMDescription Catalog Number Subscriber socket Connection via junction boxesRS485 double shielded twisted pair CablesTSX P ACC TSX CSA500Communication parameters ConfigurationControl via Modbus in I/O profile Control CommandControl via Modbus or the terminals in I/O profile Parameter Value CommentControl via Modbus or the terminals in Drivecom profile Control via Modbus in Drivecom profileConfiguration Communication scanner Example of configuration via the graphic display terminalRDY NET COM. Scanner InputCOM. Fault Management Communication faultsMonitored parameters CONFIG. COMM. MAPFormat Format Range Terminal displayChecking the address DiagnosticsLEDs Green RUN Red ERR Meaning Corrective actionCommunication MAP RUN NETCOM. Scanner Input MAP COM Scan Output MAP CMD. Word ImageOutput variable Scanner parameter Input variable Scanner parameterCOM Scan Output MAP Card fault Communication faultPrinciple Modbus protocolSlave Slave j Slave k Ascii mode RTU modeModes Slave address Function code DataRead Holding/Input Registers 3/4 Modbus functions availableCode Modbus name Description Broadcast Size of data Write Single Register Diagnostics Write Multiple Registers 16 = 16#10 Get Comm Event Counter 11 = 16#0BRead/Write Multiple Registers 23 = 16#17 Machine Read Device Identification 43 = 16#2BMEI Example of positive responseInput variables Logic address Default assignment Output variables Logic address Default assignmentCode Modbus name Description Size of data Parameter Logic Read Input variable address Logic address Default valueParameter Logic Parameter assigned Output controlInput monitoring Value Parameter assignedException responses Code Error codeResponse Logic address Parameter Value Read non-existent or protected parametersRS485 standard AppendixMaster Modbus 2-wire standard schematicModbus 4-wire standard schematic Uni-Telway schematic Type of trunk cable Cable with 1 shielded twisted pair Wire Jbus schematicDifferent scenarios Creating a Modbus bus using non-standard equipmentRecommendations Example Calculating the polarizationCard connector pinout RS485 schematic for the cardContact no. Signal SUB-DAtv71ModbusJbusENV1 2005-05