Modbus 4-wire standard schematic
Install
Error messages
Uni-Telway schematic
Contact no. Signal
Communication faults
Connecting to the bus
Configuration
Diagnostics
Connection accessories
Hardware setup
Page 41
9.
Appendix
9. 3. Modbus
4-wire
standard schematic
Master
G
TXD1
LT
Slave pair
TXD0
RXD1
LT
Master pair
RXD0
R
5 V
Rp
LT
Rp
5 V
Rp
LT
Rp
Common
G
R
G
R
Slave 1
Slave n
41
Page 40
Page 42
Image 41
Page 40
Page 42
Contents
Altivar
Contents
Electric shock will result in death or serious injury
Before you begin
Documentation structure
Installation Manual
Programming Manual
Communication Parameters Manual
Notation
Introduction
Presentation
Installing the card in the drive
Hardware setup
Receipt
Hardware description
Coding the address
Switch coding
Choosing polarization
1234
Address
Modbus RS485 standard
Connecting to the bus
Wiring recommendations
Connection cables
Connection via RJ45 wiring system
Connection accessories
Type of master Master interface Description Catalog number
Connection cables for the master
TWD XCA RJ030
TSX SCP CM
Description Catalog Number Subscriber socket
Connection via junction boxes
RS485 double shielded twisted pair
Cables
TSX P ACC
TSX CSA500
Communication parameters
Configuration
Control via Modbus in I/O profile
Control Command
Control via Modbus or the terminals in I/O profile
Parameter Value Comment
Control via Modbus or the terminals in Drivecom profile
Control via Modbus in Drivecom profile
Configuration
Communication scanner
Example of configuration via the graphic display terminal
RDY NET
COM. Scanner Input
COM. Fault Management
Communication faults
Monitored parameters
CONFIG. COMM. MAP
Format
Format Range Terminal display
Checking the address
Diagnostics
LEDs
Green RUN Red ERR Meaning Corrective action
Communication MAP
RUN NET
COM. Scanner Input MAP
COM Scan Output MAP CMD. Word Image
COM Scan Output MAP
Input variable Scanner parameter
Output variable Scanner parameter
Card fault
Communication fault
Slave Slave j Slave k
Modbus protocol
Principle
Ascii mode
RTU mode
Modes
Slave address Function code Data
Code Modbus name Description Broadcast Size of data
Modbus functions available
Read Holding/Input Registers 3/4
Write Single Register
Diagnostics
Write Multiple Registers 16 = 16#10
Get Comm Event Counter 11 = 16#0B
Read/Write Multiple Registers 23 = 16#17
Machine
Read Device Identification 43 = 16#2B
MEI
Example of positive response
Code Modbus name Description Size of data
Output variables Logic address Default assignment
Input variables Logic address Default assignment
Parameter Logic
Input variable address Logic address Default value
Parameter Logic Read
Parameter assigned
Output control
Input monitoring
Value Parameter assigned
Response
Code Error code
Exception responses
Logic address Parameter Value
Read non-existent or protected parameters
RS485 standard
Appendix
Master
Modbus 2-wire standard schematic
Modbus 4-wire standard schematic
Uni-Telway schematic
Type of trunk cable Cable with 1 shielded twisted pair
Wire Jbus schematic
Recommendations
Creating a Modbus bus using non-standard equipment
Different scenarios
Example
Calculating the polarization
Card connector pinout
RS485 schematic for the card
Contact no. Signal
SUB-D