Emerson 36J22, 36J54, 36J24, 36J55 installation instructions Precautions, Parts and Accessories

Page 2

SPECIFICATIONS

Parts and Accessories:

Natural to Regulated LP Gas Conversion Kits

F92-0659for Single Stage

F92-1008for Two-Stage

Natural to Unregulated LP Gas Conversion Kit

F92-0737

LP to Natural Gas Conversion Kits

F92-0656for Single Stage

F92-1011for Two-Stage

Note: Two single stage kits may be used for two- stage valve

PRECAUTIONS

DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING PRECAUTIONS.

 

! WARNING

 

If you do not follow these instructions exactly, a fire or explosion

 

 

mayresult,causingpropertydamage,personalinjuryorlossoflife.

 

 

1.Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion.

2.Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and may cause shock or fire hazard.

3.NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS– COULD CAUSE FIRE AND/OR EXPLOSION.

4.Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or

property damage, gas suffocation, fire, and/or explosion may result.

5.Do not use a gas valve which appears to be damaged. A damaged valve may cause personal injury and/or property damage due to shock, gas suffocation, fire and/or explosion. Contact supplier to replace any valve that appears to have been damaged.

6.Do not use a gas valve that has been in direct contact with water. Water entering gas valve may result in concealed internal damage to gas valve. Personal injury and/ or property damage, gas suffocation, fire and/or explosion may result.

!WARNING

Properly install gas piping to control.

Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.

Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.

Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the supply pipe. Do not grip bracket, solenoid or any other part of control.

Do not over-tighten pipe to control (50ft-lbs max.)

Always install sediment trap in the gas supply line to prevent contamination of gas valve. Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.

!CAUTION

1.Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or personal injury.

2.This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.).

3.Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm- fully with the gas valve components before install.

2

Image 2 Contents
Contents SpecificationsInstallation Instructions DescriptionMayresult,causingpropertydamage,personalinjuryorlossoflife PrecautionsParts and Accessories LP GAS Conversion InstallationMain Piping Connections System Wiring Single Stage Valve Features, Terminals and WiringTypical Wiring for Hot Surface Ignition System GASSingle Stage Valve AdjustmentPressure Regulator Adjustment For Your Safety Read Before Operating Lighting InstructionsPage Table DES Matières Instructions D’INSTALLATIONSpécifications Pièce N 37-7338AOu une explosion pourrait survenir et causer des dommages Pièces et accessoiresPrécautions Matériels, des blessures ou des pertes de viePrincipaux Raccords DE Tuyaux Conversion AU GPLCâblage DU Système Caractéristiques, bornes et câblage du robinet mono-étageAdaptateur de harnais de fils Robinet mono-étage AjustementAjustement DU Régulateur DE Pression Instructions D’ALLUMAGE Pour Votre SÉCURITÉ, Lire Avant L’UTILISATIONWhite-Rodgers est une entreprise d’Emerson Electric Co Instrucciones DE Instalación DescripciónEspecificaciones ContenidoPérdida de vidas PrecaucionesPiezas y accesorios Conversión Para GAS DE Petróleo Licuado InstalaciónConexiones DE LAS Tuberías Principales Nota Incluya Siempre UNA Pata DE Goteo EN LAS TuberíasConexiones DEL Sistema On/OffAdaptador para arnés de cables Ajuste Ajuste DEL Regulador DE PresiónInstrucciones DE Encendido POR SU SEGURIDAD, LEA Antes DE Utilizar
Related manuals