York YK-ZCU4x0-0, YKSMU2x0-0, YK-ZCU2x0-0 user manual User’s Manual

Page 1

York Commercial Comfort System System Manager/Zone Coordinator

User’s Manual

YK-SMU2x0-0, YK-ZCU2x0-0, YK-ZCU4x0-0

YCCS System Manager / Zone Coordinator

Image 1
Contents User’s Manual System Manager/Zone Coordinator Setup Procedures Basic ProceduresScheduling Procedures Zones, Groups, and Members Event SchedulingSummary Procedures Alarm ProceduresZone Setup Procedures Zoning System Setup ProceduresDial-up Communication Procedures Auxiliary Points Setup ProceduresDocument Introduction System Manager/Zone Coordinator on the Network System Startup System ConfigurationLocal Controller Display Menu Structure System Manager/Coordinator Menu StructureZC6 Details Screen LayoutIcons on Main Selection Bar Main Display Area Title AreaHelp Text/Paging Information Area Navigation AreaThree User Password Levels Enter Password ScreenEnter Operator password List of Default Passwords Default Passwords ProvidedContents of Home Screen Display Home ScreensDisplay and Navigation Screens YK-SMU-0 SetupSchedule 1 Mon Occupancy Time Data Entry ScreensRemote User Interface Specifying User Name and Password in BrowserTypes of Alarms Alarms and Alarm PrioritiesAlarm Detection Alarm DestinationsBuffer Limitation PagersEvent Scheduling Zones, Groups, and MembersText Messages Temporary Occupancy OverrideTrend Data Collection Global and Instant ShutdownAll Schedules Temporary Occupancy Exception SchedulesDisplay Units on User Interface Display UnitsMaintenance Procedures Entering Your Password Basic ProceduresWaking up the Display Logging Off the Remote User Interface Logging On the Remote User InterfaceSetup Options Menu Structure Setup ProceduresTime Management Setting Date and Time ParametersTime Management Parameters Change Operator Password Changing the Administrator or Operator PasswordSecurity Password Enabling or Disabling Password SecurityRemote User Interface Enabling or Disabling the Remote User InterfaceSetting up a Modem Modem SetupModem Parameters Specifying Ethernet SettingsEthernet Parameters Ethernet SetupSelecting Display Units YK-SMU-0 Display SetupCalibrating the Display Calibrate Screen System Manager Name Specifying System Manager/Zone Coordinator NameJob Name Entering Job NameScheduling Procedures Schedule Options Menu Structures Adding a Schedule Schedule 1 Daily SchedulesExample Schedules Screen for Monday Schedule 1 Schedule MonDelete Schedule Screen Deleting a ScheduleAdding a Member to a Schedule Select New Member for ScheduleDeleting a Member from a Schedule Schedule 1 Member ListProperties for Exception May 15, 2008 through May 15 Adding an Exception ScheduleProperties for Exception Definition Screen Setting up Temporary Occupancy TimeTemporary Occupancy Time Beginning Temporary Occupancy of a ScheduleBeginning or Ending Temporary Occupancy to All Schedules Ending Temporary Occupancy of a ScheduleAlarm Options Menu Structure Alarm ProceduresConfiguring Pager as Alarm Destination Pager SetupPager Setup Parameters Part 1 Pager Setup Parameters Part 2 Email SetupConfiguring E-mail Account as Alarm Destination Configuring Text Message as Alarm Destination Mail Destination Setup ParametersText Message Setup Parameters Part 1 Text Message SetupSetting Alarm Indicators Text Message Setup Parameters Part 2Alarm Priorities that Activate Alarm Indicators Alarm Priorities That Activate Alarm Indicators ScreenViewing an Alarm Summary YK-SMU-10 AlarmsAlarms Detail Screen Deleting One or All AlarmsSummary Options Menu Structure Summary ProceduresViewing System Summaries YK-SMU-10 SummaryViewing Trend Data ZC6 Zone Temperature TrendZone Setup Options Menu Structure Zone Setup ProceduresSetting Up a Changeover Bypass Zone ZC6 Zone SetupSetting Up a CV RTU Zone Zone Setup ParametersCV RTU Zone Setup Parameters CV RTU 24 Zone SetupSetting up a VAV RTU Zone VAV 24 Zone SetupVAV RTU Zone Setup Parameters Zone Name Editing a Zone NameViewing Zone Status ZC6 Zone StatusCopying Zone Setup to All Zones Instant Shutdown of All Systems Requesting Global Shutdown of all Zones in all SystemsViewing Device Diagnostics CV RTU1 DiagnosticZoning System Setup Options Menu Structure Zoning System Setup ProceduresSetting Up a Zoning System YK-ZCU Zoning System SetupZoning System Setup Parameters VAV RTU Zoning System Setup ParametersViewing Zoning System Status YK-ZCU Zoning System StatusInstant Shutdown of CV RTU24 Requesting Instant Shutdown of a Zoning SystemBalancing a Zoning System Balance ModeAuxiliary Points Setup Options Menu Structure Auxiliary Points Setup ProceduresIOM Points Setup Selections Part 1 Setting up Auxiliary PointsIOM-1 Auxiliary Points Selection BO4 IOM Points Setup Selections Part 2IOM Name Editing an IOM Controller NameViewing Auxiliary Points Status IOM-1 Auxiliary Points DetailsViewing IOM Controller Point Trend Data AI1 TrendCreating a Dial-up Connection Dial-up Communication ProceduresGetting Ready Window Connection Name Window Connection Availability Window Completing the New Connection Wizard New Connection Window Connection Window Dialing up a System Manager or CoordinatorMaintenance Options Menu Structure YK-SMU-0 Backup to USB Flash Drive Backing up Current ConfigurationYK-SMU-0 Restore from USB Flash Drive Restoring Configuration InformationRestore Confirmation Screen System Manager YK-SMU-0 Restore Factory Defaults Restoring Factory SettingsYK-SMU-0 Relearn Connected Devices Relearning Connected DevicesRestarting the System Manager/Zone Coordinator

YK-ZCU2x0-0, YKSMU2x0-0, YK-ZCU4x0-0 specifications

York YK chillers are known for their reliability, efficiency, and advanced technology, making them a popular choice for a wide range of commercial applications. Among the various models, the YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 stand out for their innovative features and performance capabilities.

The YK-ZCU4x0-0 is designed to offer maximum cooling capacity while maintaining energy efficiency. One of its main features is the variable speed drive technology, which allows for precise control of the compressor speed based on real-time cooling demands. This technology not only enhances energy savings but also reduces wear and tear on components, extending the unit's lifespan. Additionally, the YK-ZCU4x0-0 is equipped with advanced microchannel heat exchanger technology, enabling better heat transfer and smaller refrigerant charges, which contributes to its lower environmental impact.

The YKSMU2x0-0 model is particularly notable for its integrated controls and monitoring systems. This chiller comes with a user-friendly touch screen interface that allows operators to monitor performance metrics and make adjustments with ease. The model features an intelligent control system that optimizes operational efficiency by adapting to changing load conditions. Moreover, its robust design makes it suitable for diverse applications, from data centers to manufacturing facilities, where reliability is crucial.

Finally, the YK-ZCU2x0-0 emphasizes modular design, which allows for easy installation and scalability. Its compact footprint makes it suitable for spaces with limited installation area. This model also supports modular redundancy, ensuring that if one module experiences issues, others can take over without disruption to the cooling process. The combination of high-efficiency performance, modularity, and state-of-the-art features makes the YK-ZCU2x0-0 an attractive option for facility managers looking for dependable chillers.

In summary, the York YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 chillers represent the forefront of cooling technology, offering advanced features that cater to energy efficiency, flexibility, and operational reliability. Whether needing a robust solution for cooling large industrial spaces or a more compact unit for specific applications, these models provide the versatility and performance required in today's demanding environments.