York YK-ZCU2x0-0, YKSMU2x0-0, YK-ZCU4x0-0 user manual VAV RTU Zone Setup Parameters

Page 65

428516-YUM-B-0908

6.Press the button for the zone parameter you want to change. The button label describes the current setting. When you press the button, the appropriate screen appears allowing you to change the value. Table 17 lists these parameters and their ranges or possible selections.

Table 17: VAV RTU Zone Setup Parameters

Parameter

 

Parameter Range/Selections

Thermostat Warm/Cool Adjust

 

Enabled or Disabled

 

 

 

Temporary Occupancy Input

 

Enabled or Disabled

 

 

 

Supply Area

 

Valid range 0.001 to 9.999 sq ft

 

 

 

Supply Pickup Gain

 

Valid range 0.001 to 9.999

 

 

 

Heating Unocc Min Flow

 

Valid range 0 to 9,999 cfm

 

 

 

Heating Occ Min Flow

 

Valid range 0 to 9,999 cfm

 

 

 

Cooling Occ Min Flow

 

Valid range 0 to 9,999 cfm

 

 

 

Cooling Unocc Min Flow

 

Valid range 0 to 9,999 cfm

 

 

 

Heating Unocc Setpoint

 

Valid range 55.0 to 68.0 Deg F1

Heating Occ Setpoint

 

Valid range 62.0 to 72.0 Deg F1

Cooling Occ Setpoint

 

Valid range 68.0 to 78.0 Deg F1

Cooling Unocc Setpoint

 

Valid range 75.0 to 90.0 Deg F1

Cooling Max Flow

 

Valid range 53 to 9,999 cfm

 

 

 

Warm-up Min Flow

 

Valid range 0 to 9,999 cfm

 

 

 

CO2 Ventilation Cutoff

 

Valid range 0 to 2,000 ppm

 

 

 

Box Mode

 

Auto, Open, Closed, Minimum Position, Maximum

 

 

 

Position

 

 

 

 

1.Heating Unoccupied <= Heating Occupied <= Cooling Occupied <= Cooling Unoccupied

7.If you want to edit the name of the zone, press the Edit Zone Name button. On the Zone Name screen that appears, use the on-screen keyboard to enter a new name. Click OK to save.

8.If you want to apply these zone settings to all zones currently defined, press the Copy Zone Setup to All Other Zones button. A confirmation message appears. Press OK to perform the copy operation.

9.After you complete the zone setup changes, press OK. The Zone Setup screen returns, reflecting the changes you made.

System Manager/Zone Coordinator User’s Manual

65

Image 65
Contents User’s Manual System Manager/Zone Coordinator Setup Procedures Basic ProceduresScheduling Procedures Zones, Groups, and Members Event SchedulingSummary Procedures Alarm ProceduresZone Setup Procedures Zoning System Setup ProceduresDial-up Communication Procedures Auxiliary Points Setup ProceduresDocument Introduction System Manager/Zone Coordinator on the Network System Startup System ConfigurationLocal Controller Display Menu Structure System Manager/Coordinator Menu StructureIcons on Main Selection Bar Screen LayoutZC6 Details Main Display Area Title AreaHelp Text/Paging Information Area Navigation AreaEnter Operator password Enter Password ScreenThree User Password Levels List of Default Passwords Default Passwords ProvidedContents of Home Screen Display Home ScreensDisplay and Navigation Screens YK-SMU-0 SetupSchedule 1 Mon Occupancy Time Data Entry ScreensRemote User Interface Specifying User Name and Password in BrowserTypes of Alarms Alarms and Alarm PrioritiesAlarm Detection Alarm DestinationsBuffer Limitation PagersEvent Scheduling Zones, Groups, and MembersText Messages Temporary Occupancy OverrideTrend Data Collection Global and Instant ShutdownAll Schedules Temporary Occupancy Exception SchedulesDisplay Units on User Interface Display UnitsMaintenance Procedures Waking up the Display Basic ProceduresEntering Your Password Logging Off the Remote User Interface Logging On the Remote User InterfaceSetup Options Menu Structure Setup ProceduresTime Management Parameters Setting Date and Time ParametersTime Management Change Operator Password Changing the Administrator or Operator PasswordSecurity Password Enabling or Disabling Password SecurityRemote User Interface Enabling or Disabling the Remote User InterfaceSetting up a Modem Modem SetupModem Parameters Specifying Ethernet SettingsEthernet Parameters Ethernet SetupCalibrating the Display YK-SMU-0 Display SetupSelecting Display Units Calibrate Screen System Manager Name Specifying System Manager/Zone Coordinator NameJob Name Entering Job NameScheduling Procedures Schedule Options Menu Structures Adding a Schedule Schedule 1 Daily SchedulesExample Schedules Screen for Monday Schedule 1 Schedule MonDelete Schedule Screen Deleting a ScheduleAdding a Member to a Schedule Select New Member for ScheduleDeleting a Member from a Schedule Schedule 1 Member ListProperties for Exception May 15, 2008 through May 15 Adding an Exception ScheduleProperties for Exception Definition Screen Setting up Temporary Occupancy TimeTemporary Occupancy Time Beginning Temporary Occupancy of a ScheduleBeginning or Ending Temporary Occupancy to All Schedules Ending Temporary Occupancy of a ScheduleAlarm Options Menu Structure Alarm ProceduresPager Setup Parameters Part 1 Pager SetupConfiguring Pager as Alarm Destination Configuring E-mail Account as Alarm Destination Email SetupPager Setup Parameters Part 2 Configuring Text Message as Alarm Destination Mail Destination Setup ParametersText Message Setup Parameters Part 1 Text Message SetupSetting Alarm Indicators Text Message Setup Parameters Part 2Alarm Priorities that Activate Alarm Indicators Alarm Priorities That Activate Alarm Indicators ScreenViewing an Alarm Summary YK-SMU-10 AlarmsAlarms Detail Screen Deleting One or All AlarmsSummary Options Menu Structure Summary ProceduresViewing System Summaries YK-SMU-10 SummaryViewing Trend Data ZC6 Zone Temperature TrendZone Setup Options Menu Structure Zone Setup ProceduresSetting Up a Changeover Bypass Zone ZC6 Zone SetupSetting Up a CV RTU Zone Zone Setup ParametersCV RTU Zone Setup Parameters CV RTU 24 Zone SetupSetting up a VAV RTU Zone VAV 24 Zone SetupVAV RTU Zone Setup Parameters Zone Name Editing a Zone NameViewing Zone Status ZC6 Zone StatusCopying Zone Setup to All Zones Instant Shutdown of All Systems Requesting Global Shutdown of all Zones in all SystemsViewing Device Diagnostics CV RTU1 DiagnosticZoning System Setup Options Menu Structure Zoning System Setup ProceduresSetting Up a Zoning System YK-ZCU Zoning System SetupZoning System Setup Parameters VAV RTU Zoning System Setup ParametersViewing Zoning System Status YK-ZCU Zoning System StatusInstant Shutdown of CV RTU24 Requesting Instant Shutdown of a Zoning SystemBalancing a Zoning System Balance ModeAuxiliary Points Setup Options Menu Structure Auxiliary Points Setup ProceduresIOM-1 Auxiliary Points Selection Setting up Auxiliary PointsIOM Points Setup Selections Part 1 BO4 IOM Points Setup Selections Part 2IOM Name Editing an IOM Controller NameViewing Auxiliary Points Status IOM-1 Auxiliary Points DetailsViewing IOM Controller Point Trend Data AI1 TrendCreating a Dial-up Connection Dial-up Communication ProceduresGetting Ready Window Connection Name Window Connection Availability Window Completing the New Connection Wizard New Connection Window Connection Window Dialing up a System Manager or CoordinatorMaintenance Options Menu Structure YK-SMU-0 Backup to USB Flash Drive Backing up Current ConfigurationYK-SMU-0 Restore from USB Flash Drive Restoring Configuration InformationRestore Confirmation Screen System Manager YK-SMU-0 Restore Factory Defaults Restoring Factory SettingsYK-SMU-0 Relearn Connected Devices Relearning Connected DevicesRestarting the System Manager/Zone Coordinator

YK-ZCU2x0-0, YKSMU2x0-0, YK-ZCU4x0-0 specifications

York YK chillers are known for their reliability, efficiency, and advanced technology, making them a popular choice for a wide range of commercial applications. Among the various models, the YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 stand out for their innovative features and performance capabilities.

The YK-ZCU4x0-0 is designed to offer maximum cooling capacity while maintaining energy efficiency. One of its main features is the variable speed drive technology, which allows for precise control of the compressor speed based on real-time cooling demands. This technology not only enhances energy savings but also reduces wear and tear on components, extending the unit's lifespan. Additionally, the YK-ZCU4x0-0 is equipped with advanced microchannel heat exchanger technology, enabling better heat transfer and smaller refrigerant charges, which contributes to its lower environmental impact.

The YKSMU2x0-0 model is particularly notable for its integrated controls and monitoring systems. This chiller comes with a user-friendly touch screen interface that allows operators to monitor performance metrics and make adjustments with ease. The model features an intelligent control system that optimizes operational efficiency by adapting to changing load conditions. Moreover, its robust design makes it suitable for diverse applications, from data centers to manufacturing facilities, where reliability is crucial.

Finally, the YK-ZCU2x0-0 emphasizes modular design, which allows for easy installation and scalability. Its compact footprint makes it suitable for spaces with limited installation area. This model also supports modular redundancy, ensuring that if one module experiences issues, others can take over without disruption to the cooling process. The combination of high-efficiency performance, modularity, and state-of-the-art features makes the YK-ZCU2x0-0 an attractive option for facility managers looking for dependable chillers.

In summary, the York YK-ZCU4x0-0, YKSMU2x0-0, and YK-ZCU2x0-0 chillers represent the forefront of cooling technology, offering advanced features that cater to energy efficiency, flexibility, and operational reliability. Whether needing a robust solution for cooling large industrial spaces or a more compact unit for specific applications, these models provide the versatility and performance required in today's demanding environments.