ADVANCED OPERATION

Now that you’re mastered the basics of VX-177operation, let’s learn more about some of the really neat features.

KEYBOARD LOCKING

In order to prevent accidental frequency change or inadvertent transmission, various as- pects of the VX-177’s DIAL and keypad may be locked out. The possible lockout combi- nations are:

LK KEY: Just the front panel keypad is locked out

LKDIAL: Just the top panel DIAL is locked out

LK K+D:Both the keypad and DIAL are locked out (factory default) LK PTT: The PTT switch is locked out (TX not possible)

LK P+K: Both the PTT switch and keypad are locked out LK P+D:Both the PTT switch and DIAL are locked out LK ALL: All of the above are locked out

To lock out some or all of the keys:

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select Set Mode Item 26: LOCK.

3. Press the [F] key momentarily to enable adjustment of this Item.

4. Rotate the DIAL knob to choose between one of the locking schemes as outlined above.

5.When you have made your selection, press the PTT switch to save the new setting and return to normal operation.

To activate the locking feature, (1) press and hold in the [6(LOCK)] key for one second, or (2) press the [F] key, followed by the [6(LOCK)] key. The “” icon will appear on the LCD. To cancel locking, repeat one of these processes.

16

VX-177 OPERATING MANUAL

Image 18
Contents Vertex Standard Yaesu Europe B.VContents General Description Accessories & Options Supplied AccessoriesAvailable Options Controls & Connectors TOP & Front Panels Controls & Connectors LCD Controls & Connectors Side Panel PTT Push To Talk SwitchMoni Switch Controls & Connectors Keypad Functions Press F + KEYOne step or moves the memory Installation of Accessories Antenna InstallationInstallation of FNB-83 Battery Pack Battery Charging LOW Battery IndicationBelt Clip Installation Installation of FBA-25A Alkaline Battery Case OptionInterface of Packet Tncs Switching Power on and OFF Adjusting the Audio Volume LevelOperation Tuning Dial Squelch AdjustmentFrequency Navigation Direct Keypad Frequency Entry ScanningChanging the Transmitter Power Level TransmissionAdvanced Operation Keyboard LockingKEYPAD/LCD Illumination Disabling the Keypad BeeperChecking the Battery Voltage RF SquelchRepeater Operation Repeater ShiftsAutomatic Repeater Shift ARS Changing the Default Repeater Shifts Manual Repeater Shift ActivationVFO Split Mode Checking the Repeater Uplink Input FrequencyRepeater Operation CTCSS/DCS/EPCS Operation Ctcss OperationDCS Operation Tone Search Scanning Storing the Ctcss Tone Pairs for Epcs Operation Epcs Enhanced Paging & Code SquelchCTCSS/DCS/EPCS Bell Operation Activating the Enhanced Paging & Code Squelch SystemSplit Tone Operation Tone Calling 1750 HZMemory Mode Storing Independent Transmit Frequencies Odd SplitsMemory Storage Memory Recall Home Channel MemoryLabeling Memories Memory Offset Tuning Deleting MemoriesRemoving Memories from a Memory Bank Assigning Memories to a Memory BankMemory Bank Recall Memory Bank OperationMemory only Mode Moving Memory Data to the VFOVX-177 Operating Manual Setting the Scan-Resume Technique ScanningManual VFO Scan Programmed VFO ScanVFO Scanning How to Skip Omit a Channel during Memory Scan Operation Memory ScanningPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Home Channel Priority VFO PriorityMemory Channel Priority Priority Channel Scanning Dual WatchPriority Revert Mode VFO-VFO Dual WatchAutomatic Lamp Illumination on Scan Stop Band Edge BeeperVX-177 Operating Manual Emergency Feature Emergency Channel OperationEmergency Automatic ID EAI Feature Emergency Feature Setting the Smart Search Mode Smart Search OperationStoring Smart Search Memories Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Polling Time Options Arts Alert Beep OptionsCW Identifier Setup Dtmf Operation Manual Dtmf Tone GenerationDtmf Autodialer To send the telephone number Dtmf Pager Operation Requires Optional FTD-7 Storing the 3-digit code for the Dtmf Pager OperationActivating the Dtmf Pager Activating the ANI feature Storing the ANI codeMiscellaneous Settings PasswordProgramming the KEY Assignments Changing the Channel StepsReceive Battery Saver Setup TX Battery SaverDisabling the TX/BUSY Indicator Automatic POWER-OFF APO FeatureTransmitter TIME-OUT Timer TOT Busy Channel LOCK-OUT BcloDCS Code Inversion Changing the TX Deviation Level Reset Procedures Cloning Try againVX-177 Operating Manual SET Menu Mode ARSNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 3 AR INT Set Mode Item 1 APOSet Mode Item 2 AR BEP Set Mode Item 4 ARSSet Mode Item 10 Cwid Set Mode Item 8 BSY.LEDSet Mode Item 9 CLK.SFT Set Mode Item 11 CW WRTSet Mode Item 19 ECS.CDT Set Mode Item 17 DT WRTSet Mode Item 18 ECS.CDR Set Mode Item 20 EDG.BEPSet Mode Item 24 INT MR Set Mode Item 22 I NETSet Mode Item 23 INT CD Set Mode Item 25 LampSet Mode Item 29 NM WRT Set Mode Item 27 M/T-CLSet Mode Item 28 Name Set Mode Item 30 PswdSet Mode Item 35 RPT.MOD Set Mode Item 33 REV/HMSet Mode Item 34 RF SQL Set Mode Item 36 PRI.RVTSet Mode Item 41 Shift Set Mode Item 39 SCN MDSet Mode Item 40 SCN.LMP Set Mode Item 42 SkipSet Mode Item 46 TN FRQ Set Mode Item 44 SQL.TYPSet Mode Item 45 Step Set Mode Item 47 TOTSet Mode Item 53 ANI Set Mode Item 51 WID.NARSet Mode Item 52 EAI Set Mode Item 54 ANI.WRTSpecifications GeneralInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K