Vertex Standard VX-177 manual Programming the KEY Assignments, Changing the Channel Steps

Page 63

MISCELLANEOUS SETTINGS

PASSWORD

If you forget the password number, you may turn on the transceiver by per- forming the “All Reset” procedure (see page 67). However, the VX-177 will clear the password, as well as all memories, and will restore all other settings

to factory defaults.

PROGRAMMING THE KEY ASSIGNMENTS

Default VX-177Set Mode Items have been assigned (at the factory) to the [7(P1)] and [8(P2)] keys. These may be changed by the user, if you wish to assign another Set Mode Item to either or both of these keys.

To change the assignment of a key’s Set Mode Item:

1.Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2.Rotate the DIAL knob to select the Set Mode Item which you wish to assign to the key as a Menu short-cut.

3.Press and hold in the [7(P1)] or [8(P2)] key for one second to assign the Set Mode Item to the [7(P1)] or [8(P2)] key.

The following Set Mode Items may not be assigned to the [7(P1)] and [8(P2)] keys. Set Mode Item 11: CW WRT

Set Mode Item 17: DT WRT

Set Mode Item 31: PSWD W

CHANGING THE CHANNEL STEPS

The VX-177’s synthesizer provides the option of utilizing channel steps of 5/10/12.5/15/ 20/25/50/100 kHz per step, as well as an automatic step selection based on the current operating frequency (“AUTO”), any number of which may be important to your operating requirements. The VX-177is set up at the factory in the “AUTO” configuration, which probably is satisfactory for most operation. However, if you need to change the channel step increments, the procedure to do so is very easy.

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select Set Mode Item 45: STEP.

3. Press the [F] key momentarily to enable adjustment of this Item. 4. Rotate the DIAL knob to select the new channel step size. 5. When you have made your selection, press the PTT switch to

save the new setting and return to normal operation.

VX-177 OPERATING MANUAL

61

Image 63
Contents Yaesu Europe B.V Vertex StandardContents General Description Accessories & Options Supplied AccessoriesAvailable Options Controls & Connectors TOP & Front Panels Controls & Connectors LCD Controls & Connectors Side Panel PTT Push To Talk SwitchMoni Switch Press F + KEY Controls & Connectors Keypad FunctionsOne step or moves the memory Installation of Accessories Antenna InstallationInstallation of FNB-83 Battery Pack LOW Battery Indication Battery ChargingInstallation of FBA-25A Alkaline Battery Case Option Belt Clip InstallationInterface of Packet Tncs Switching Power on and OFF Adjusting the Audio Volume LevelOperation Tuning Dial Squelch AdjustmentFrequency Navigation Scanning Direct Keypad Frequency EntryTransmission Changing the Transmitter Power LevelKeyboard Locking Advanced OperationDisabling the Keypad Beeper KEYPAD/LCD IlluminationRF Squelch Checking the Battery VoltageRepeater Operation Repeater ShiftsAutomatic Repeater Shift ARS Manual Repeater Shift Activation Changing the Default Repeater ShiftsChecking the Repeater Uplink Input Frequency VFO Split ModeRepeater Operation Ctcss Operation CTCSS/DCS/EPCS OperationDCS Operation Tone Search Scanning Epcs Enhanced Paging & Code Squelch Storing the Ctcss Tone Pairs for Epcs OperationActivating the Enhanced Paging & Code Squelch System CTCSS/DCS/EPCS Bell OperationTone Calling 1750 HZ Split Tone OperationMemory Mode Storing Independent Transmit Frequencies Odd SplitsMemory Storage Home Channel Memory Memory RecallLabeling Memories Deleting Memories Memory Offset TuningMemory Bank Operation Assigning Memories to a Memory BankMemory Bank Recall Removing Memories from a Memory BankMoving Memory Data to the VFO Memory only ModeVX-177 Operating Manual Scanning Setting the Scan-Resume TechniqueManual VFO Scan Programmed VFO ScanVFO Scanning Memory Scanning How to Skip Omit a Channel during Memory Scan OperationPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Priority Channel Scanning Dual Watch VFO PriorityMemory Channel Priority Home Channel PriorityVFO-VFO Dual Watch Priority Revert ModeBand Edge Beeper Automatic Lamp Illumination on Scan StopVX-177 Operating Manual Emergency Channel Operation Emergency FeatureEmergency Automatic ID EAI Feature Emergency Feature Setting the Smart Search Mode Smart Search OperationStoring Smart Search Memories Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Alert Beep Options Arts Polling Time OptionsCW Identifier Setup Dtmf Operation Manual Dtmf Tone GenerationDtmf Autodialer To send the telephone number Storing the 3-digit code for the Dtmf Pager Operation Dtmf Pager Operation Requires Optional FTD-7Activating the Dtmf Pager Storing the ANI code Activating the ANI featurePassword Miscellaneous SettingsChanging the Channel Steps Programming the KEY AssignmentsTX Battery Saver Receive Battery Saver SetupAutomatic POWER-OFF APO Feature Disabling the TX/BUSY IndicatorBusy Channel LOCK-OUT Bclo Transmitter TIME-OUT Timer TOTDCS Code Inversion Changing the TX Deviation Level Reset Procedures Try again CloningVX-177 Operating Manual ARS SET Menu ModeNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 4 ARS Set Mode Item 1 APOSet Mode Item 2 AR BEP Set Mode Item 3 AR INTSet Mode Item 11 CW WRT Set Mode Item 8 BSY.LEDSet Mode Item 9 CLK.SFT Set Mode Item 10 CwidSet Mode Item 20 EDG.BEP Set Mode Item 17 DT WRTSet Mode Item 18 ECS.CDR Set Mode Item 19 ECS.CDTSet Mode Item 25 Lamp Set Mode Item 22 I NETSet Mode Item 23 INT CD Set Mode Item 24 INT MRSet Mode Item 30 Pswd Set Mode Item 27 M/T-CLSet Mode Item 28 Name Set Mode Item 29 NM WRTSet Mode Item 36 PRI.RVT Set Mode Item 33 REV/HMSet Mode Item 34 RF SQL Set Mode Item 35 RPT.MODSet Mode Item 42 Skip Set Mode Item 39 SCN MDSet Mode Item 40 SCN.LMP Set Mode Item 41 ShiftSet Mode Item 47 TOT Set Mode Item 44 SQL.TYPSet Mode Item 45 Step Set Mode Item 46 TN FRQSet Mode Item 54 ANI.WRT Set Mode Item 51 WID.NARSet Mode Item 52 EAI Set Mode Item 53 ANIGeneral SpecificationsInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K