Vertex Standard VX-177 manual Scanning, Setting the Scan-Resume Technique

Page 38

SCANNING

The VX-177allows you to scan just the memory channels, the entire operating band, or a portion of that band. It will halt on signals encountered, so you can talk to the station(s) on that frequency, if you like.

Scanning operation is basically the same in each of the above modes. Before you begin, take a moment to select the way in which you would like the scanner to resume scanning after it halts on a signal.

Setting the Scan-Resume Technique

Three options for the Scan-Resume mode are available:

BUSY: In this mode, the scanner will halt on a signal it encounters. Two seconds after the carrier has dropped because the other station(s) ceased transmission, the scanner will resume. In the case of constant-carrier signals like Weather Station broad- casts, the scanner will likely remain on this frequency indefinitely.

HOLD: In this mode, the scanner will halt on a signal it encounters. It will not restart automatically; you must manually re-initiate scanning if you wish to resume.

TIME: In this mode, the scanner will halt on a signal it encounters, and will hold there for five seconds. If you do not take action to disable the scanner within that time period, the scanner will resume even if the stations are still active.

To set the Scan-Resume mode:

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select Set Mode Item 32: RESUME.

3. Press the [F] key momentarily to enable adjustment of this Set Mode Item.

4. Rotate the DIAL knob to select the desired scan-resume mode.

5. When you have made your selection, press the PTT switch to save the new setting and exit to normal operation.

The default condition for this Set Mode Item is “BUSY.”

SETTING THE SQUELCH LEVEL DURING ACTIVE SCANNING OPERATION

The VX-177allows adjustment of the Squelch level “on the fly” while you are scanning. 1. While the scanner is engaged, press the [F] key, then press

the MONI switch (the current squelch level (e.g. “S 3”) will appear in fine print above the frequency display).

2.Rotate the DIAL to select the desired Squelch level.

3.Press the PTT switch momentarily to save the new setting and exit to normal operation. In this case, pressing the PTT switch this one time will not causing scanning to stop.

36

VX-177 OPERATING MANUAL

Image 38 Contents
Vertex Standard Yaesu Europe B.VContents General Description Available Options Accessories & OptionsSupplied Accessories Controls & Connectors TOP & Front Panels Controls & Connectors LCD Moni Switch Controls & Connectors Side PanelPTT Push To Talk Switch Controls & Connectors Keypad Functions Press F + KEYOne step or moves the memory Installation of FNB-83 Battery Pack Installation of AccessoriesAntenna Installation Battery Charging LOW Battery IndicationBelt Clip Installation Installation of FBA-25A Alkaline Battery Case OptionInterface of Packet Tncs Operation Switching Power on and OFFAdjusting the Audio Volume Level Frequency Navigation Tuning DialSquelch Adjustment Direct Keypad Frequency Entry ScanningChanging the Transmitter Power Level TransmissionAdvanced Operation Keyboard LockingKEYPAD/LCD Illumination Disabling the Keypad BeeperChecking the Battery Voltage RF SquelchAutomatic Repeater Shift ARS Repeater OperationRepeater Shifts Changing the Default Repeater Shifts Manual Repeater Shift ActivationVFO Split Mode Checking the Repeater Uplink Input FrequencyRepeater Operation CTCSS/DCS/EPCS Operation Ctcss OperationDCS Operation Tone Search Scanning Storing the Ctcss Tone Pairs for Epcs Operation Epcs Enhanced Paging & Code SquelchCTCSS/DCS/EPCS Bell Operation Activating the Enhanced Paging & Code Squelch SystemSplit Tone Operation Tone Calling 1750 HZMemory Storage Memory ModeStoring Independent Transmit Frequencies Odd Splits Memory Recall Home Channel MemoryLabeling Memories Memory Offset Tuning Deleting Memories Removing Memories from a Memory Bank Assigning Memories to a Memory Bank Memory Bank Recall Memory Bank OperationMemory only Mode Moving Memory Data to the VFOVX-177 Operating Manual Setting the Scan-Resume Technique ScanningVFO Scanning Manual VFO ScanProgrammed VFO Scan How to Skip Omit a Channel during Memory Scan Operation Memory ScanningPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Home Channel Priority VFO PriorityMemory Channel Priority Priority Channel Scanning Dual WatchPriority Revert Mode VFO-VFO Dual WatchAutomatic Lamp Illumination on Scan Stop Band Edge BeeperVX-177 Operating Manual Emergency Feature Emergency Channel OperationEmergency Automatic ID EAI Feature Emergency Feature Storing Smart Search Memories Setting the Smart Search ModeSmart Search Operation Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Polling Time Options Arts Alert Beep OptionsCW Identifier Setup Dtmf Autodialer Dtmf OperationManual Dtmf Tone Generation To send the telephone number Dtmf Pager Operation Requires Optional FTD-7 Storing the 3-digit code for the Dtmf Pager OperationActivating the Dtmf Pager Activating the ANI feature Storing the ANI codeMiscellaneous Settings PasswordProgramming the KEY Assignments Changing the Channel StepsReceive Battery Saver Setup TX Battery SaverDisabling the TX/BUSY Indicator Automatic POWER-OFF APO FeatureTransmitter TIME-OUT Timer TOT Busy Channel LOCK-OUT BcloDCS Code Inversion Changing the TX Deviation Level Reset Procedures Cloning Try againVX-177 Operating Manual SET Menu Mode ARSNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 3 AR INT Set Mode Item 1 APOSet Mode Item 2 AR BEP Set Mode Item 4 ARSSet Mode Item 10 Cwid Set Mode Item 8 BSY.LEDSet Mode Item 9 CLK.SFT Set Mode Item 11 CW WRTSet Mode Item 19 ECS.CDT Set Mode Item 17 DT WRTSet Mode Item 18 ECS.CDR Set Mode Item 20 EDG.BEPSet Mode Item 24 INT MR Set Mode Item 22 I NETSet Mode Item 23 INT CD Set Mode Item 25 LampSet Mode Item 29 NM WRT Set Mode Item 27 M/T-CLSet Mode Item 28 Name Set Mode Item 30 PswdSet Mode Item 35 RPT.MOD Set Mode Item 33 REV/HMSet Mode Item 34 RF SQL Set Mode Item 36 PRI.RVTSet Mode Item 41 Shift Set Mode Item 39 SCN MDSet Mode Item 40 SCN.LMP Set Mode Item 42 SkipSet Mode Item 46 TN FRQ Set Mode Item 44 SQL.TYPSet Mode Item 45 Step Set Mode Item 47 TOTSet Mode Item 53 ANI Set Mode Item 51 WID.NARSet Mode Item 52 EAI Set Mode Item 54 ANI.WRTSpecifications GeneralInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K