EMERGENCY FEATURE

EMERGENCY AUTOMATIC ID (EAI) FEATURE

The Emergency Automatic ID (EAI) feature can be used for searching for persons who are incapacitated in disasters like earthquakes, especially search-and-rescue personnel who may have become injured in a debris field. In such cases, if another searcher sends out a unique command (CTCSS tone pair), the radio of the incapacitated party, who may not be able to speak or even press the PTT switch, will automatically cause the injured party’s radio to transmit, so others may perform direction-finding and effect a rescue. The callsign of the incapacitated person will also be transmitted, to assist the rescue team.

If an emergency group is working in a dangerous area, all members should engage the EAI feature on their transceiver, so that others can provide assistance to a fallen team member, if necessary.

The Emergency Automatic ID (EAI) Feature has two operating modes: (1) Interval mode and (2) Continuous mode.

In the Interval mode, when the VX-177receives the CTCSS tone pair which is stored in the Receiving Pager Code Memory (configured via Set Mode Item 18: ECS.CDR) on the frequency which is stored in Memory Channel “200” for more than five seconds, the radio will automatically transmit a brief (0.5 second) beep tone every 2.5 seconds until the EAI timer expiration at the power level stored in that memory channel; it is NOT necessary for the incapacitated person to press the PTT switch.

In the Continuous mode, when the VX-177receives the CTCSS tone pair which is stored in the Receiving Pager Code Memory (configured via Set Mode Item 18: ECS.CDR) on the frequency which is stored in Memory Channel “200” for more than five seconds, the radio will automatically transmit (with maximum microphone gain) continuously, until the EAI timer expiration, at the power level stored in that memory channel; it is NOT necessary for the incapacitated person to press the PTT switch.

Furthermore, if your call sign is stored in the radio via Set Mode Item 11: CW WRT and you have

enabled the CW identifier by Set Mode Item 10: CWID, the radio will transmit your callsign on the air when the EAI feature is first engaged by the remote page, and every 10 minutes thereater.

The “callsign” ID can be changed to any desired sequence of characters, such as a name. After sending the callsign or name, the radio will repeatedly transmit three tones for a user- defined period of time (between 1 and 30 minutes). The callsign or name will be transmit- ted every 10 minutes.

VX-177 OPERATING MANUAL

47

Image 49
Contents Yaesu Europe B.V Vertex StandardContents General Description Supplied Accessories Accessories & OptionsAvailable Options Controls & Connectors TOP & Front Panels Controls & Connectors LCD PTT Push To Talk Switch Controls & Connectors Side PanelMoni Switch Press F + KEY Controls & Connectors Keypad FunctionsOne step or moves the memory Antenna Installation Installation of AccessoriesInstallation of FNB-83 Battery Pack LOW Battery Indication Battery ChargingInstallation of FBA-25A Alkaline Battery Case Option Belt Clip InstallationInterface of Packet Tncs Adjusting the Audio Volume Level Switching Power on and OFFOperation Squelch Adjustment Tuning DialFrequency Navigation Scanning Direct Keypad Frequency EntryTransmission Changing the Transmitter Power LevelKeyboard Locking Advanced OperationDisabling the Keypad Beeper KEYPAD/LCD IlluminationRF Squelch Checking the Battery VoltageRepeater Shifts Repeater OperationAutomatic Repeater Shift ARS Manual Repeater Shift Activation Changing the Default Repeater ShiftsChecking the Repeater Uplink Input Frequency VFO Split ModeRepeater Operation Ctcss Operation CTCSS/DCS/EPCS OperationDCS Operation Tone Search Scanning Epcs Enhanced Paging & Code Squelch Storing the Ctcss Tone Pairs for Epcs OperationActivating the Enhanced Paging & Code Squelch System CTCSS/DCS/EPCS Bell OperationTone Calling 1750 HZ Split Tone OperationStoring Independent Transmit Frequencies Odd Splits Memory ModeMemory Storage Home Channel Memory Memory RecallLabeling Memories Deleting Memories Memory Offset TuningMemory Bank Recall Assigning Memories to a Memory BankRemoving Memories from a Memory Bank Memory Bank OperationMoving Memory Data to the VFO Memory only ModeVX-177 Operating Manual Scanning Setting the Scan-Resume TechniqueProgrammed VFO Scan Manual VFO ScanVFO Scanning Memory Scanning How to Skip Omit a Channel during Memory Scan OperationPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Memory Channel Priority VFO PriorityHome Channel Priority Priority Channel Scanning Dual WatchVFO-VFO Dual Watch Priority Revert ModeBand Edge Beeper Automatic Lamp Illumination on Scan StopVX-177 Operating Manual Emergency Channel Operation Emergency FeatureEmergency Automatic ID EAI Feature Emergency Feature Smart Search Operation Setting the Smart Search ModeStoring Smart Search Memories Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Alert Beep Options Arts Polling Time OptionsCW Identifier Setup Manual Dtmf Tone Generation Dtmf OperationDtmf Autodialer To send the telephone number Storing the 3-digit code for the Dtmf Pager Operation Dtmf Pager Operation Requires Optional FTD-7Activating the Dtmf Pager Storing the ANI code Activating the ANI featurePassword Miscellaneous SettingsChanging the Channel Steps Programming the KEY AssignmentsTX Battery Saver Receive Battery Saver SetupAutomatic POWER-OFF APO Feature Disabling the TX/BUSY IndicatorBusy Channel LOCK-OUT Bclo Transmitter TIME-OUT Timer TOTDCS Code Inversion Changing the TX Deviation Level Reset Procedures Try again CloningVX-177 Operating Manual ARS SET Menu ModeNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 2 AR BEP Set Mode Item 1 APOSet Mode Item 3 AR INT Set Mode Item 4 ARSSet Mode Item 9 CLK.SFT Set Mode Item 8 BSY.LEDSet Mode Item 10 Cwid Set Mode Item 11 CW WRTSet Mode Item 18 ECS.CDR Set Mode Item 17 DT WRTSet Mode Item 19 ECS.CDT Set Mode Item 20 EDG.BEPSet Mode Item 23 INT CD Set Mode Item 22 I NETSet Mode Item 24 INT MR Set Mode Item 25 LampSet Mode Item 28 Name Set Mode Item 27 M/T-CLSet Mode Item 29 NM WRT Set Mode Item 30 PswdSet Mode Item 34 RF SQL Set Mode Item 33 REV/HMSet Mode Item 35 RPT.MOD Set Mode Item 36 PRI.RVTSet Mode Item 40 SCN.LMP Set Mode Item 39 SCN MDSet Mode Item 41 Shift Set Mode Item 42 SkipSet Mode Item 45 Step Set Mode Item 44 SQL.TYPSet Mode Item 46 TN FRQ Set Mode Item 47 TOTSet Mode Item 52 EAI Set Mode Item 51 WID.NARSet Mode Item 53 ANI Set Mode Item 54 ANI.WRTGeneral SpecificationsInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K