SET (MENU) MODE
REPEATER SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Enables/Disables the Automatic Repeater Shift function. | 4 [ARS] | ARS. ON / ARS.OFF | |
Sets the Repeater Shift Direction. | 35 | [RPT.MOD] | RPT.OFF / RPT. |
Sets the magnitude of the repeater Shift. | 41 | [SHIFT] | 0.00 - 99.95 MHz () |
CTCSS/DSC/DTMF/EPCS SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Selects the number of CTCSS/DCS Bell ringer repetitions. | 7 [BELL] | OFF / 1T / 3T / 5T / 8T / CONT | |
Setting of the DCS code. | 13 | [DCS.COD] | 104 standard DCS codes (023) |
Enables/Disables “Inverted” DCS code decoding. | 14 | [DCS.N/R] | T/RX N, RX R, TX R, T/RX R |
Setting of the DTMF Autodialer Delay Time. | 15 | [DT DLY] | 50MS / 100MS / 250MS / 450MS / |
|
|
| 750MS / 1000MS |
Setting of the DTMF Autodialer Sending Speed. | 16 | [DT SPD] | 50MS /100MS |
Programming of the DTMF Autodialer. | 17 [DT WRT] | – | |
Setting the Receiver Pager Code for the Enhanced CTCSS | 18 | [ECS.CDR] | (R05_47) |
Paging & Code Squelch. |
|
|
|
Setting the Transmitting Pager Code for the Enhanced | 19 | [ECS.CDT] | (T05_47) |
CTCSS Paging & Code Squelch. |
|
|
|
Enables/Disables split CTCSS/DCS coding. | 43 | [SPLIT] | SPL.OFF / SPL. ON |
Selects the Tone Encoder and/or Decoder mode. | 44 | [SQL.TYP] | OFF / TONE / TSQL / |
|
|
| REV TN / DCS |
Setting of the CTCSS Tone Frequency. | 46 | [TN FRQ] | 50 standard CTCSS tones (100 Hz) |
ARTS SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Selects the Beep option during ARTS operation. | 2 [AR BEP] | INRANG / ALWAYS / OFF | |
Selects the Polling Interval during ARTS operation. | 3 [AR INT] | 25 SEC / 15 SEC | |
Enables/disables the CW identifier during ARTS operation. | 10 | [CWID] | TX OFF / TX ON |
Programs and activates the CW Identifier (used duringARTS | 11 [CW WRT] | – | |
operation). |
|
|
|
MEMORY SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Toggles the display indication between “frequency” and the | 28 | [NAME] | FREQ / ALPHA |
channel’s “Alpha/Numeric Tag.” |
|
|
|
Stores | 29 | [NM WRT] | – |
SCAN SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Selects the Scan Resume mode. | 32 | [RESUME] | BUSY / HOLD / TIME |
Enables/disables the Priority Revert feature. | 36 | [PRI.RVT] | RVT.OFF / RVT. ON |
Selects the Memory Scan | 39 | [SCN MD] | ONLY / MEM |
Enables/Disables the Scan lamp while paused. | 40 | [SCN.LMP] | ON / OFF |
Selects the Memory Scan “Skip” | 42 | [SKIP] | OFF / SKIP / ONLY |
POWER SAVER SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Selects the | 37 | [RXSAVE] | 200 MS / 300 MS / 500 MS / |
ratio). |
|
| 1 S / 2 S / OFF |
Enables/Disables the Transmitter Battery Saver. | 49 | [TXSAVE] | SAV.OFF / SAV. ON |
WIRES™ SETTING | SET MODE ITEM | AVAILABLE VALUES (DEFAULT) | |
Selects the Internet Link Connection mode. | 22 | [I NET] | INT.OFF / INT.COD / INT.MEM |
Selects the Access Number (DTMF digit) for WIRES™ op- | 23 | [INT CD] | CODE 0 - CODE 9, |
eration. |
|
| CODE A - CODE F, (CODE 1) |
Selects the memory register for an Access Number (DTMF | 24 | [INT MR] | d1 - d9 |
digit) for |
|
|
|
72 |