Vertex Standard VX-177 How to Skip Omit a Channel during Memory Scan Operation, Memory Scanning

Page 40

SCANNING

MEMORY SCANNING

Memory scanning is similarly easy to initiate:

1.Select the Memory mode by pressing the [MR(SKIP)] key, if necessary.

2.Press and hold in either the [￿(MHz)] or [￿(MHz)] key for one second to initiate upward or downward scanning, respectively.

3.If and when the scanner encounters a signal strong enough to open the squelch, the scanner will halt temporarily; the decimal point of the frequency display will blink during this “Pause” condition.

4.The scanner will then resume according to the Scan-Resume mode selected in the previous section.

5.To cancel scanning, press the PTT switch or [MR(SKIP)] key.

How to Skip (Omit) a Channel during Memory Scan Operation

As mentioned previously, some continuous-carrier stations like a Weather Broadcast sta- tion will seriously impede scanner operation if you are using the “Carrier Drop” Scan- Resume mode, as the incoming signal will not pause long enough for the transceiver to resume scanning. Such channels may be “Skipped” during scanning, if you like:

1.Recall the Memory Channel to be skipped during scanning.

2.Press the [F] key, then press the [MR(SKIP)] key to enter the “Skip” channel-selec- tion mode.

3. Rotate the DIAL knob so as to select “SKIP.” The current Memory Channel will now be ignored during scanning. The “ONLY” se- lection is used for “Preferential Memory Scan,” described in the next section.

4.When you have made your selection, press the PTT switch to save the setting and exit to normal operation.

When you recall the “skipped” memory channel manually, a small “￿” icon will appear at the left of the memory channel number, indi- cating it is to be ignored during scanning.

To re-institute a channel into the scanning loop, select “OFF” in step 3 above (the “Skipped” channel will, of course, still be accessible via manual channel selection methods using the DIAL knob in the MR mode, whether or not it is locked out of the scanning loop).

38

VX-177 OPERATING MANUAL

Image 40 Contents
Vertex Standard Yaesu Europe B.VContents General Description Supplied Accessories Accessories & OptionsAvailable Options Controls & Connectors TOP & Front Panels Controls & Connectors LCD PTT Push To Talk Switch Controls & Connectors Side PanelMoni Switch Controls & Connectors Keypad Functions Press F + KEYOne step or moves the memory Antenna Installation Installation of AccessoriesInstallation of FNB-83 Battery Pack Battery Charging LOW Battery IndicationBelt Clip Installation Installation of FBA-25A Alkaline Battery Case OptionInterface of Packet Tncs Adjusting the Audio Volume Level Switching Power on and OFFOperation Squelch Adjustment Tuning DialFrequency Navigation Direct Keypad Frequency Entry ScanningChanging the Transmitter Power Level TransmissionAdvanced Operation Keyboard LockingKEYPAD/LCD Illumination Disabling the Keypad BeeperChecking the Battery Voltage RF SquelchRepeater Shifts Repeater OperationAutomatic Repeater Shift ARS Changing the Default Repeater Shifts Manual Repeater Shift ActivationVFO Split Mode Checking the Repeater Uplink Input FrequencyRepeater Operation CTCSS/DCS/EPCS Operation Ctcss OperationDCS Operation Tone Search Scanning Storing the Ctcss Tone Pairs for Epcs Operation Epcs Enhanced Paging & Code SquelchCTCSS/DCS/EPCS Bell Operation Activating the Enhanced Paging & Code Squelch SystemSplit Tone Operation Tone Calling 1750 HZStoring Independent Transmit Frequencies Odd Splits Memory ModeMemory Storage Memory Recall Home Channel MemoryLabeling Memories Memory Offset Tuning Deleting MemoriesAssigning Memories to a Memory Bank Memory Bank RecallRemoving Memories from a Memory Bank Memory Bank OperationMemory only Mode Moving Memory Data to the VFO VX-177 Operating Manual Setting the Scan-Resume Technique ScanningProgrammed VFO Scan Manual VFO ScanVFO Scanning How to Skip Omit a Channel during Memory Scan Operation Memory ScanningPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS VFO Priority Memory Channel PriorityHome Channel Priority Priority Channel Scanning Dual WatchPriority Revert Mode VFO-VFO Dual WatchAutomatic Lamp Illumination on Scan Stop Band Edge BeeperVX-177 Operating Manual Emergency Feature Emergency Channel OperationEmergency Automatic ID EAI Feature Emergency Feature Smart Search Operation Setting the Smart Search ModeStoring Smart Search Memories Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Polling Time Options Arts Alert Beep OptionsCW Identifier Setup Manual Dtmf Tone Generation Dtmf OperationDtmf Autodialer To send the telephone number Dtmf Pager Operation Requires Optional FTD-7 Storing the 3-digit code for the Dtmf Pager OperationActivating the Dtmf Pager Activating the ANI feature Storing the ANI codeMiscellaneous Settings PasswordProgramming the KEY Assignments Changing the Channel StepsReceive Battery Saver Setup TX Battery SaverDisabling the TX/BUSY Indicator Automatic POWER-OFF APO FeatureTransmitter TIME-OUT Timer TOT Busy Channel LOCK-OUT BcloDCS Code Inversion Changing the TX Deviation Level Reset Procedures Cloning Try againVX-177 Operating Manual SET Menu Mode ARSNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 1 APO Set Mode Item 2 AR BEPSet Mode Item 3 AR INT Set Mode Item 4 ARSSet Mode Item 8 BSY.LED Set Mode Item 9 CLK.SFTSet Mode Item 10 Cwid Set Mode Item 11 CW WRTSet Mode Item 17 DT WRT Set Mode Item 18 ECS.CDRSet Mode Item 19 ECS.CDT Set Mode Item 20 EDG.BEPSet Mode Item 22 I NET Set Mode Item 23 INT CDSet Mode Item 24 INT MR Set Mode Item 25 LampSet Mode Item 27 M/T-CL Set Mode Item 28 NameSet Mode Item 29 NM WRT Set Mode Item 30 PswdSet Mode Item 33 REV/HM Set Mode Item 34 RF SQLSet Mode Item 35 RPT.MOD Set Mode Item 36 PRI.RVTSet Mode Item 39 SCN MD Set Mode Item 40 SCN.LMPSet Mode Item 41 Shift Set Mode Item 42 SkipSet Mode Item 44 SQL.TYP Set Mode Item 45 StepSet Mode Item 46 TN FRQ Set Mode Item 47 TOTSet Mode Item 51 WID.NAR Set Mode Item 52 EAISet Mode Item 53 ANI Set Mode Item 54 ANI.WRTSpecifications GeneralInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K