Vertex Standard VX-177 manual Checking the Repeater Uplink Input Frequency, VFO Split Mode

Page 23

REPEATER OPERATION

MANUAL REPEATER SHIFT ACTIVATION

Checking the Repeater Uplink (Input) Frequency

It often is helpful to be able to check the uplink (input) frequency of a repeater, to see if the calling station is within direct (“Simplex”) range.

To do this, just press the [REV(HOME)] key. You’ll notice that the display has shifted to the repeater uplink frequency. Press the [REV(HOME)] key again to cause operation to revert to normal monitoring of the repeater downlink (out- put) frequency. While you are listening on the input fre- quency to the repeater using the [REV(HOME)] key, the repeater offset icon will blink.

The configuration of this key may be set either to “RV” (for checking the input fre- quency of a repeater), or “HM” (for instant switching to the “Home” channel for the band you are operating on). To change the configuration of this key, use Set Mode Item 33: REV/HM. See page 79.

VFO SPLIT MODE

For working on repeaters with odd splits, or communicating with astronauts on orbiting space vehicles, it may be necessary to use non-standard splits between the receive and transmit frequency. If the application is infrequent enough not to warrant the dedication of a memory channel for this purpose, the “VFO Split” mode may be used. Here is the proce- dure for going Split:

1.Press the [VFO(PRI)] key, as needed, to select VFO-A. Set VFO-A for the desired receiving (downlink) frequency (e.g.439.700 MHz).

2.Now press the [VFO(PRI)] key, and set VFO-B for the desired transmit (uplink) fre- quency (e.g. 434.900 MHz).

3.Press the [VFO(PRI)] key once more to re-establish VFO-A as the “Main” (receive) VFO.

4.Press the [F] key, then press the [0(SET)] key to enter the Set mode.

5. Rotate the DIAL to select Set Mode Item 50: VFO.SPL.

6. Press the [F] key, then rotate the DIAL to set this function “VSP. ON.”

7. Press the PTT switch once to save the new setting and exit to

normal operation. 8. You will now be operating in the Split mode. When you press

the PTT switch to transmit, you will observe that VFO-A and

VFO-B will reverse positions. The VFO selection indicator -b- will blink while the transceiver is transmitting, this means that the VFO Split feature is now activated.

VX-177 OPERATING MANUAL

21

Image 23
Contents Yaesu Europe B.V Vertex StandardContents General Description Available Options Accessories & OptionsSupplied Accessories Controls & Connectors TOP & Front Panels Controls & Connectors LCD Moni Switch Controls & Connectors Side PanelPTT Push To Talk Switch Press F + KEY Controls & Connectors Keypad FunctionsOne step or moves the memory Installation of FNB-83 Battery Pack Installation of AccessoriesAntenna Installation LOW Battery Indication Battery ChargingInstallation of FBA-25A Alkaline Battery Case Option Belt Clip InstallationInterface of Packet Tncs Operation Switching Power on and OFFAdjusting the Audio Volume Level Frequency Navigation Tuning DialSquelch Adjustment Scanning Direct Keypad Frequency EntryTransmission Changing the Transmitter Power LevelKeyboard Locking Advanced OperationDisabling the Keypad Beeper KEYPAD/LCD IlluminationRF Squelch Checking the Battery VoltageAutomatic Repeater Shift ARS Repeater OperationRepeater Shifts Manual Repeater Shift Activation Changing the Default Repeater ShiftsChecking the Repeater Uplink Input Frequency VFO Split ModeRepeater Operation Ctcss Operation CTCSS/DCS/EPCS OperationDCS Operation Tone Search Scanning Epcs Enhanced Paging & Code Squelch Storing the Ctcss Tone Pairs for Epcs OperationActivating the Enhanced Paging & Code Squelch System CTCSS/DCS/EPCS Bell OperationTone Calling 1750 HZ Split Tone OperationMemory Storage Memory ModeStoring Independent Transmit Frequencies Odd Splits Home Channel Memory Memory RecallLabeling Memories Deleting Memories Memory Offset TuningMemory Bank Operation Assigning Memories to a Memory BankMemory Bank Recall Removing Memories from a Memory BankMoving Memory Data to the VFO Memory only ModeVX-177 Operating Manual Scanning Setting the Scan-Resume TechniqueVFO Scanning Manual VFO ScanProgrammed VFO Scan Memory Scanning How to Skip Omit a Channel during Memory Scan OperationPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Priority Channel Scanning Dual Watch VFO PriorityMemory Channel Priority Home Channel PriorityVFO-VFO Dual Watch Priority Revert ModeBand Edge Beeper Automatic Lamp Illumination on Scan StopVX-177 Operating Manual Emergency Channel Operation Emergency FeatureEmergency Automatic ID EAI Feature Emergency Feature Storing Smart Search Memories Setting the Smart Search ModeSmart Search Operation Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Alert Beep Options Arts Polling Time OptionsCW Identifier Setup Dtmf Autodialer Dtmf OperationManual Dtmf Tone Generation To send the telephone number Storing the 3-digit code for the Dtmf Pager Operation Dtmf Pager Operation Requires Optional FTD-7Activating the Dtmf Pager Storing the ANI code Activating the ANI featurePassword Miscellaneous SettingsChanging the Channel Steps Programming the KEY AssignmentsTX Battery Saver Receive Battery Saver SetupAutomatic POWER-OFF APO Feature Disabling the TX/BUSY IndicatorBusy Channel LOCK-OUT Bclo Transmitter TIME-OUT Timer TOTDCS Code Inversion Changing the TX Deviation Level Reset Procedures Try again CloningVX-177 Operating Manual ARS SET Menu ModeNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 4 ARS Set Mode Item 1 APOSet Mode Item 2 AR BEP Set Mode Item 3 AR INTSet Mode Item 11 CW WRT Set Mode Item 8 BSY.LEDSet Mode Item 9 CLK.SFT Set Mode Item 10 CwidSet Mode Item 20 EDG.BEP Set Mode Item 17 DT WRTSet Mode Item 18 ECS.CDR Set Mode Item 19 ECS.CDTSet Mode Item 25 Lamp Set Mode Item 22 I NETSet Mode Item 23 INT CD Set Mode Item 24 INT MRSet Mode Item 30 Pswd Set Mode Item 27 M/T-CLSet Mode Item 28 Name Set Mode Item 29 NM WRTSet Mode Item 36 PRI.RVT Set Mode Item 33 REV/HMSet Mode Item 34 RF SQL Set Mode Item 35 RPT.MODSet Mode Item 42 Skip Set Mode Item 39 SCN MDSet Mode Item 40 SCN.LMP Set Mode Item 41 ShiftSet Mode Item 47 TOT Set Mode Item 44 SQL.TYPSet Mode Item 45 Step Set Mode Item 46 TN FRQSet Mode Item 54 ANI.WRT Set Mode Item 51 WID.NARSet Mode Item 52 EAI Set Mode Item 53 ANIGeneral SpecificationsInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K