SCANNING

AUTOMATIC LAMP ILLUMINATION ON SCAN STOP

The VX-177will automatically illuminate the LCD/Keypad Lamp whenever the scanner stops on a signal; this allows you to see the frequency of the incoming signal better at night. Note that this will, of course, increase the battery consumption, so be sure to switch it off during the day (the default condition for this feature is “ON”).

The procedure for disabling the Scan Lamp is:

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select Set Mode Item 40: SCN.LMP.

3. Press the [F] key momentarily to enable adjustment of this Set Mode Item.

4. Rotate the DIAL knob to set this Set Mode Item to “OFF.”

5.When you have made your selection, press the PTT switch to save the setting and exit to normal operation.

BAND EDGE BEEPER

The VX-177will automatically “beep” when a band edge is encountered during scanning (either in standard VFO scanning or during PMS operation). You may also enable this feature (band edge beeper) to operate when the frequency reaches the band edge while tuning using the DIAL knob.

The procedure for enabling the Band-Edge Beeper is:

1. Press the [F] key, then press the [0(SET)] key to enter the Set mode.

2. Rotate the DIAL knob to select Set Mode Item 20: EDG.BEP.

3. Press the [F] key momentarily to enable adjustment of this Set Mode Item.

4. Rotate the DIAL knob to set this Set Mode Item to “BEP. ON.”

5. When you have made your selection, press the PTT switch to save the setting and exit to normal operation.

44

VX-177 OPERATING MANUAL

Image 46
Contents Vertex Standard Yaesu Europe B.VContents General Description Supplied Accessories Accessories & OptionsAvailable Options Controls & Connectors TOP & Front Panels Controls & Connectors LCD PTT Push To Talk Switch Controls & Connectors Side PanelMoni Switch Controls & Connectors Keypad Functions Press F + KEYOne step or moves the memory Antenna Installation Installation of AccessoriesInstallation of FNB-83 Battery Pack Battery Charging LOW Battery IndicationBelt Clip Installation Installation of FBA-25A Alkaline Battery Case OptionInterface of Packet Tncs Adjusting the Audio Volume Level Switching Power on and OFFOperation Squelch Adjustment Tuning DialFrequency Navigation Direct Keypad Frequency Entry ScanningChanging the Transmitter Power Level TransmissionAdvanced Operation Keyboard LockingKEYPAD/LCD Illumination Disabling the Keypad BeeperChecking the Battery Voltage RF SquelchRepeater Shifts Repeater OperationAutomatic Repeater Shift ARS Changing the Default Repeater Shifts Manual Repeater Shift ActivationVFO Split Mode Checking the Repeater Uplink Input FrequencyRepeater Operation CTCSS/DCS/EPCS Operation Ctcss OperationDCS Operation Tone Search Scanning Storing the Ctcss Tone Pairs for Epcs Operation Epcs Enhanced Paging & Code SquelchCTCSS/DCS/EPCS Bell Operation Activating the Enhanced Paging & Code Squelch SystemSplit Tone Operation Tone Calling 1750 HZStoring Independent Transmit Frequencies Odd Splits Memory ModeMemory Storage Memory Recall Home Channel MemoryLabeling Memories Memory Offset Tuning Deleting MemoriesRemoving Memories from a Memory Bank Assigning Memories to a Memory BankMemory Bank Recall Memory Bank OperationMemory only Mode Moving Memory Data to the VFOVX-177 Operating Manual Setting the Scan-Resume Technique ScanningProgrammed VFO Scan Manual VFO ScanVFO Scanning How to Skip Omit a Channel during Memory Scan Operation Memory ScanningPreferential Memory Scan Memory Bank Scan Programmable Band Limit Memory Scan PMS Home Channel Priority VFO PriorityMemory Channel Priority Priority Channel Scanning Dual WatchPriority Revert Mode VFO-VFO Dual WatchAutomatic Lamp Illumination on Scan Stop Band Edge BeeperVX-177 Operating Manual Emergency Feature Emergency Channel OperationEmergency Automatic ID EAI Feature Emergency Feature Smart Search Operation Setting the Smart Search ModeStoring Smart Search Memories Internet Connection Feature Internet Connection Feature Basic Arts Setup and Operation Arts Polling Time Options Arts Alert Beep OptionsCW Identifier Setup Manual Dtmf Tone Generation Dtmf OperationDtmf Autodialer To send the telephone number Dtmf Pager Operation Requires Optional FTD-7 Storing the 3-digit code for the Dtmf Pager OperationActivating the Dtmf Pager Activating the ANI feature Storing the ANI codeMiscellaneous Settings PasswordProgramming the KEY Assignments Changing the Channel StepsReceive Battery Saver Setup TX Battery SaverDisabling the TX/BUSY Indicator Automatic POWER-OFF APO FeatureTransmitter TIME-OUT Timer TOT Busy Channel LOCK-OUT BcloDCS Code Inversion Changing the TX Deviation Level Reset Procedures Cloning Try againVX-177 Operating Manual SET Menu Mode ARSNET CTCSS/DSC/DTMF/EPCS Setting ANI Set Mode Item 3 AR INT Set Mode Item 1 APOSet Mode Item 2 AR BEP Set Mode Item 4 ARSSet Mode Item 10 Cwid Set Mode Item 8 BSY.LEDSet Mode Item 9 CLK.SFT Set Mode Item 11 CW WRTSet Mode Item 19 ECS.CDT Set Mode Item 17 DT WRTSet Mode Item 18 ECS.CDR Set Mode Item 20 EDG.BEPSet Mode Item 24 INT MR Set Mode Item 22 I NETSet Mode Item 23 INT CD Set Mode Item 25 LampSet Mode Item 29 NM WRT Set Mode Item 27 M/T-CLSet Mode Item 28 Name Set Mode Item 30 PswdSet Mode Item 35 RPT.MOD Set Mode Item 33 REV/HMSet Mode Item 34 RF SQL Set Mode Item 36 PRI.RVTSet Mode Item 41 Shift Set Mode Item 39 SCN MDSet Mode Item 40 SCN.LMP Set Mode Item 42 SkipSet Mode Item 46 TN FRQ Set Mode Item 44 SQL.TYPSet Mode Item 45 Step Set Mode Item 47 TOTSet Mode Item 53 ANI Set Mode Item 51 WID.NARSet Mode Item 52 EAI Set Mode Item 54 ANI.WRTSpecifications GeneralInstallation of the FTD-7 Dtmf Paging Unit Option Declaration by Manufacturer 0511X-0K