2 BATTERY CHARGING

Battery installation

Before installing, or replacing the batteries, push [PWR] for 1 sec. to turn the power OFF.

qRemove the battery cover from the receiver.

wInstall 2 R6 (AA) size Ni- Cd or Ni-MH batteries.

• Be sure to observe the cor- rect polarity.

Keep the battery contacts

clean to avoid rust or

poor contact. It’s a good

idea to clean the battery terminals once a week.

Caution

DBattery caution

CAUTION! NEVER short the battery terminals. Also, current may flow into nearby metal objects such as a necklace, so be careful when placing battery cells in handbags, etc.

NEVER mix old and new batteries.

Make sure all battery cells are the same brand, type and capacity.

Either of the above may cause a fire hazard or damage the receiver if ignored.

NEVER incinerate used battery cells. Internal battery gas may cause explosion.

If your re-chargeable batteries seem to have no capacity even after being charged, completely discharge them by leaving the power ON overnight. Then fully charge the batteries again. If the batteries still does not retain a charge (or very lit- tle charge), a new battery cells must be purchased.

DCharging caution

RWARNING! NEVER charge dry or alkaline batteries.

AVOID over charging— The installed re-chargeable batteries can be charged during operation when the AC adapter or the optional cigarette lighter cable is connected. To prevent over charging, the IC-R5 has charging timer that automatically dis- connecting the charging line electronically after 15 hours from charging. However, the charging timer will reset and start charging again when disconnect then re-connecting the AC adapter or CP-18A/E more than 1 min. interval.

Recommended temperature for charging: ±0˚C to +40˚C (; +32˚F to +140˚F)

Connect the supplied (or optional for UK and Italy versions) AC adapter or optional cigarette lighter cable only when charging the installed Ni-Cd or Ni-MH batteries. NEVER use other manufactures’ chargers.

CAUTION: BE SURE to disconnect the CP-18A/E from

the cigarette lighter socket when charging is finished, be-

cause, a slight current still follows in the CP-18A/E and the vehicle’s battery will become exhausted.

5

Image 16
Contents IR5 Explicit Definitions Precaution Supplied Accessories IiiTable of Contents Battery installation Quick Reference GuidePreparation Belt clipRotate Dial to select Y then push Band Install the Ni-Cd batteriesCharging confirmation is displayed as below Your first scanning Experience About default settingBasic operation Receive mode selection Setting frequencyMemory programming Selecting a memory ChannelProgrammed scan operation Programming scan edgesSelecting a scan edge channel a Selecting a scan edge channel BStarting scan Select VFO mode Cancelling scanSelecting a scanning type Starting scanPanel Description Front, top and side panelsPush for 1 sec. to turn the receiver power on and OFF UCONTROL Dial DialWLOCK Indicator p ERECEIVE Mode Indicator pRDUPLEX Indicators p TTONE Indicators1SIGNAL Strength Indicator p Priority Watch Indicator p2VOLUME Exchange Indicator p Battery Charging Battery installationBattery caution Charging cautionBattery charging Charging connectionsCharging description Charging periods Approx hoursVFO and memory channels Frequency and Channel SettingOperating band selection Frequency and Channel Setting Available frequency bandsSetting a frequency Setting a tuning stepTuning step selection Rotate Dial to select the desired frequency bandPush V/MS.MW~ to select the memory mode Selecting a memory channelLock function Rotate Dial to select the desired memory channelSetting audio volume When a signal is receivedBasic Operation ReceivingSquelch level setting Receive mode selectionAttenuator function Monitor functionPush and hold SQL to monitor the operating frequency Duplex operation SettingRotate Dial to select DUP Push Tsset momentarily to exit set mode Setting dial select stepDial select step Memory Channels General descriptionRotate Dial to select the desired bank channel number Memory bank settingPush V/MS.MW~ momentarily to set the channel into the bank Memory bank selection Push V/MS.MW~ to select memory mode, if desiredRotate Dial to select the bank channel To return to regular memory condition, rotate Dial whileRotate Dial to move the cursor to left or right Programming memory/bank nameAvailable characters Selecting display type Selecting bank channel indicationCopying memory contents Push V/MS.MW~ for 1 sec. to clear the contents Memory clearingWhile pushing FUNC, push V/MS.MW~ for 1 sec EssaryTransferring memory contents Erasing/transferring bank contents Scan Operation Scan typesFull Scan p FREQUENCY/MEMORY Skip Function pFull/band/programmed scan Select VFO mode with V/MS.MW~To start the scan, push Modescan Scan edges programming Example Programming 145.300 MHz into scan edges 03ASelect memory mode with V/MS.MW~ Memory/bank/all bank scanAuto memory write scan During auto-memory write scanningRe-calling the stored frequencies Clearing the stored frequenciesSkip channel/frequency setting NelScan resume timer Scan pause timerScan resume condition Priority Watch Priority watch typesAbout priority beep function Watch startsPush Tsset to exit set mode and start the watch Push Tsset to cancel the watchPriority watch operation Select memory mode, or the desired bank group thenWhen scanning memory/bank channels VFO scan watch qSelect memory mode0Push Tsset to cancel the watch and scan Tone Squelch and Pocket Beep Tone/DTCS squelch operationOPush Func to stop the beeps and blinking manually Step yAvailable Dtcs code list Tone squelch frequency/DTCS code settingAvailable tone frequency list Dtcs polarity setting Tone scan While pushing FUNC, push Modescan to start the tone scanSET Mode Set mode entering and operationExpanded set mode ON/OFF GeneralGeneral set mode items Set mode itemsExpanded set mode items Dial select step Priority watchKey-touch beep Beep output levelAntenna selection Power saveMHz differ according to version, re Monitor switch action No accessible switch is available, exceptKey lock effect Dial speed accelerationAuto power OFF Scan pause timerScan resume timer Scan stop beepDuplex direction Offset frequencyTone squelch DTone frequency Ddtcs code Dtcs polarityAvailable subaudible tone frequencies Available Dtcs codeWeather alert function LCD contrastTurns weather alert function on and OFF Antenna selection Other FunctionsSelecting antenna Weather channel operation Dial function assignmentWeather channel selection Turn the weather alert function OFF in set mode Cloning between receivers Push SQL on the master receiverCloning using a personal computer Auto power-off functionCloning error Partial reset Frequency Table TV channelsDU.S.A. channels Dccir channelsDChina channels DNewZealand ChannelsIndonesian channels DItalian channelsTaiwan channels FOT channelsVHF marine channels Weather channelsunit MHzMurs channels Other communications in the USAHF CB Citizens Band channels General aviation frequencies Wireless MicrophonesDCable TV IRC Other communications- other countries LPD Low Power Device channels Unit MHzPMR446 channels unit MHz UHF C.R.S Citizen Radio Service channels Maintenance TroubleshootingCP-18A/E fuse replacement Specifications DgeneralOptions OptionsPocket Guide Memory channel programming Declaration Conformity We Icom Inc. JapanKamiminami, Hirano-ku, Osaka 547-0003 Japan