Icom IC-R5 instruction manual Memory/bank/all bank scan, Select memory mode with V/MS.MW~

Page 39

Memory/bank/all bank scan

qSelect memory mode with [V/M•S.MW•~].

Select the desired bank with [BAND•] for bank scan. wSet the squelch to the point where noise is just muted. ePush [MODE•SCAN] for 1 sec. to;

When memory mode is selected at the step q:

-start memory scan.

When a bank channel is selected at the step q:

-enter scan type selection mode.

rRotate [DIAL] to select the desired scanning type.

“ALL” for all bank scan; “BANK” for bank scan.

[DIAL]

• All bank scan selection

 

[MODE•SCAN] • Bank scan selection

SCAN OPERATION 6

tPush [MODE•SCAN] momentarily to start all bank or bank scan.

Scan pauses when a signal is received.

Rotate [DIAL] to change the scanning direction, or resumes manually.

yTo stop the scan, push [MODE•SCAN].

• During memory/all bank scan

• During bank scan

6

WFM AM DUP T SQL DTCS

WFM AM DUP T SQL DTCS

 

IMPORTANT!: To perform memory or bank scan, 2 or

more memory/bank channels MUST be programmed, oth- erwise the scan never starts.

28

Image 39
Contents IR5 Explicit Definitions Precaution Iii Supplied AccessoriesTable of Contents Belt clip Battery installationQuick Reference Guide PreparationInstall the Ni-Cd batteries Rotate Dial to select Y then push BandCharging confirmation is displayed as below About default setting Your first scanning ExperienceBasic operation Selecting a memory Channel Receive mode selectionSetting frequency Memory programmingSelecting a scan edge channel B Programmed scan operationProgramming scan edges Selecting a scan edge channel aStarting scan Starting scan Select VFO modeCancelling scan Selecting a scanning typeFront, top and side panels Panel DescriptionUCONTROL Dial Dial Push for 1 sec. to turn the receiver power on and OFFTTONE Indicators WLOCK Indicator pERECEIVE Mode Indicator p RDUPLEX Indicators pPriority Watch Indicator p 1SIGNAL Strength Indicator p2VOLUME Exchange Indicator p Charging caution Battery ChargingBattery installation Battery cautionCharging periods Approx hours Battery chargingCharging connections Charging descriptionFrequency and Channel Setting VFO and memory channelsOperating band selection Available frequency bands Frequency and Channel SettingRotate Dial to select the desired frequency band Setting a frequencySetting a tuning step Tuning step selectionRotate Dial to select the desired memory channel Push V/MS.MW~ to select the memory modeSelecting a memory channel Lock functionReceiving Setting audio volumeWhen a signal is received Basic OperationReceive mode selection Squelch level settingMonitor function Attenuator functionPush and hold SQL to monitor the operating frequency Setting Duplex operationRotate Dial to select DUP Setting dial select step Push Tsset momentarily to exit set modeDial select step General description Memory ChannelsMemory bank setting Rotate Dial to select the desired bank channel numberPush V/MS.MW~ momentarily to set the channel into the bank To return to regular memory condition, rotate Dial while Memory bank selectionPush V/MS.MW~ to select memory mode, if desired Rotate Dial to select the bank channelProgramming memory/bank name Rotate Dial to move the cursor to left or rightAvailable characters Selecting bank channel indication Selecting display typeCopying memory contents Essary Push V/MS.MW~ for 1 sec. to clear the contentsMemory clearing While pushing FUNC, push V/MS.MW~ for 1 secTransferring memory contents Erasing/transferring bank contents FREQUENCY/MEMORY Skip Function p Scan Operation Scan types Full Scan pSelect VFO mode with V/MS.MW~ Full/band/programmed scanTo start the scan, push Modescan Example Programming 145.300 MHz into scan edges 03A Scan edges programmingMemory/bank/all bank scan Select memory mode with V/MS.MW~Clearing the stored frequencies Auto memory write scanDuring auto-memory write scanning Re-calling the stored frequenciesNel Skip channel/frequency settingScan pause timer Scan resume timerScan resume condition Watch starts Priority WatchPriority watch types About priority beep functionSelect memory mode, or the desired bank group then Push Tsset to exit set mode and start the watchPush Tsset to cancel the watch Priority watch operationVFO scan watch qSelect memory mode When scanning memory/bank channels0Push Tsset to cancel the watch and scan Step y Tone Squelch and Pocket BeepTone/DTCS squelch operation OPush Func to stop the beeps and blinking manuallyTone squelch frequency/DTCS code setting Available Dtcs code listAvailable tone frequency list Dtcs polarity setting While pushing FUNC, push Modescan to start the tone scan Tone scanGeneral SET ModeSet mode entering and operation Expanded set mode ON/OFFSet mode items General set mode itemsExpanded set mode items Beep output level Dial select stepPriority watch Key-touch beepPower save Antenna selectionMHz differ according to version, re Dial speed acceleration Monitor switch actionNo accessible switch is available, except Key lock effectScan stop beep Auto power OFFScan pause timer Scan resume timerOffset frequency Duplex directionTone squelch Available Dtcs code DTone frequency Ddtcs codeDtcs polarity Available subaudible tone frequenciesLCD contrast Weather alert functionTurns weather alert function on and OFF Other Functions Antenna selectionSelecting antenna Dial function assignment Weather channel operationWeather channel selection Turn the weather alert function OFF in set mode Push SQL on the master receiver Cloning between receiversAuto power-off function Cloning using a personal computerCloning error Partial reset Dccir channels Frequency TableTV channels DU.S.A. channelsChannels DChina channelsDNew ZealandFOT channels Indonesian channelsDItalian channels Taiwan channelsWeather channelsunit MHz VHF marine channelsOther communications in the USA Murs channelsHF CB Citizens Band channels Wireless Microphones General aviation frequenciesDCable TV IRC LPD Low Power Device channels Unit MHz Other communications- other countriesPMR446 channels unit MHz UHF C.R.S Citizen Radio Service channels Troubleshooting MaintenanceCP-18A/E fuse replacement Dgeneral SpecificationsOptions OptionsPocket Guide Memory channel programming We Icom Inc. Japan Declaration ConformityKamiminami, Hirano-ku, Osaka 547-0003 Japan