Icom IC-R5 instruction manual Auto memory write scan, During auto-memory write scanning

Page 40

6 SCAN OPERATION

Auto memory write scan

This scan is useful for searching a specified frequency range and automatically storing busy frequencies into memory channels. The same frequency ranges used for program scan are used for auto memory write scan.

qSelect VFO mode with [V/M•S.MW•~].

wPush [MODE•SCAN] for 1 sec. to enter scanning type se- lection condition.

eRotate [DIAL] to select the desired scanning type.

“ALL” for full scan; “BAND” for band scan, “PROGxx” for pro- grammed scan (xx= 0 to 24; programmed scan edges numbers only displayed)

rPush [MODE•SCAN] to start the scan.

tPush [V/M•S.MW•~] to turn the automatic memory write function ON and OFF.

” indicator blinks.

[DIAL]

• During auto memory

 

write scan

 

 

FM

P SKIP

[V/M•S.MW•~]

 

 

[MODE•SCAN]

“ ” indicator blinks dur-

 

ing auto memory

write

 

scan.

 

yPush [MODE•SCAN] to stop scan.

DDuring auto-memory write scanning:

When signal is received, scan pauses and the frequency is stored into auto memory write channel group (R000–R199).

- 2 short beeps sound when stored.

Scan resumes after frequency storing.

When all channels are stored, the scan cancels automati- cally and 1 long beep sounds.

DRe-calling the stored frequencies:

qPush [V/M•S.MW•~] to select memory mode.

wPush [BAND•] several times, or while pushing

[BAND•], rotate [DIAL] to select the auto memory write channel group.

• “R” appears.

eRotate [DIAL] to select the desired channel.

FM

R

“R” appears when auto memory write channel group is selected.

DClearing the stored frequencies:

qSelect the auto memory write channel group.

wWhile pushing [FUNC], push [V/M•S.MW•~] for 1 sec. to clear the all channels contents.

• 1 short and 1 long beeps sound.

NOTE: The auto memory write channel contents CANNOT

be cleared by an independent channel. Thus it is good idea to copy the contents into regular memory channel.

29

Image 40
Contents IR5 Explicit Definitions Precaution Supplied Accessories IiiTable of Contents Battery installation Quick Reference GuidePreparation Belt clipRotate Dial to select Y then push Band Install the Ni-Cd batteriesCharging confirmation is displayed as below Your first scanning Experience About default settingBasic operation Receive mode selection Setting frequencyMemory programming Selecting a memory ChannelProgrammed scan operation Programming scan edgesSelecting a scan edge channel a Selecting a scan edge channel BStarting scan Select VFO mode Cancelling scanSelecting a scanning type Starting scanPanel Description Front, top and side panelsPush for 1 sec. to turn the receiver power on and OFF UCONTROL Dial DialWLOCK Indicator p ERECEIVE Mode Indicator pRDUPLEX Indicators p TTONE Indicators1SIGNAL Strength Indicator p Priority Watch Indicator p2VOLUME Exchange Indicator p Battery Charging Battery installationBattery caution Charging cautionBattery charging Charging connectionsCharging description Charging periods Approx hoursVFO and memory channels Frequency and Channel SettingOperating band selection Frequency and Channel Setting Available frequency bandsSetting a frequency Setting a tuning stepTuning step selection Rotate Dial to select the desired frequency bandPush V/MS.MW~ to select the memory mode Selecting a memory channelLock function Rotate Dial to select the desired memory channelSetting audio volume When a signal is receivedBasic Operation ReceivingSquelch level setting Receive mode selectionAttenuator function Monitor functionPush and hold SQL to monitor the operating frequency Duplex operation SettingRotate Dial to select DUP Push Tsset momentarily to exit set mode Setting dial select stepDial select step Memory Channels General descriptionRotate Dial to select the desired bank channel number Memory bank settingPush V/MS.MW~ momentarily to set the channel into the bank Memory bank selection Push V/MS.MW~ to select memory mode, if desiredRotate Dial to select the bank channel To return to regular memory condition, rotate Dial whileRotate Dial to move the cursor to left or right Programming memory/bank nameAvailable characters Selecting display type Selecting bank channel indicationCopying memory contents Push V/MS.MW~ for 1 sec. to clear the contents Memory clearingWhile pushing FUNC, push V/MS.MW~ for 1 sec EssaryTransferring memory contents Erasing/transferring bank contents Scan Operation Scan typesFull Scan p FREQUENCY/MEMORY Skip Function pFull/band/programmed scan Select VFO mode with V/MS.MW~To start the scan, push Modescan Scan edges programming Example Programming 145.300 MHz into scan edges 03ASelect memory mode with V/MS.MW~ Memory/bank/all bank scanAuto memory write scan During auto-memory write scanningRe-calling the stored frequencies Clearing the stored frequenciesSkip channel/frequency setting NelScan resume timer Scan pause timerScan resume condition Priority Watch Priority watch typesAbout priority beep function Watch startsPush Tsset to exit set mode and start the watch Push Tsset to cancel the watchPriority watch operation Select memory mode, or the desired bank group thenWhen scanning memory/bank channels VFO scan watch qSelect memory mode0Push Tsset to cancel the watch and scan Tone Squelch and Pocket Beep Tone/DTCS squelch operationOPush Func to stop the beeps and blinking manually Step yAvailable Dtcs code list Tone squelch frequency/DTCS code settingAvailable tone frequency list Dtcs polarity setting Tone scan While pushing FUNC, push Modescan to start the tone scanSET Mode Set mode entering and operationExpanded set mode ON/OFF GeneralGeneral set mode items Set mode itemsExpanded set mode items Dial select step Priority watchKey-touch beep Beep output levelAntenna selection Power saveMHz differ according to version, re Monitor switch action No accessible switch is available, exceptKey lock effect Dial speed accelerationAuto power OFF Scan pause timerScan resume timer Scan stop beepDuplex direction Offset frequencyTone squelch DTone frequency Ddtcs code Dtcs polarityAvailable subaudible tone frequencies Available Dtcs codeWeather alert function LCD contrastTurns weather alert function on and OFF Antenna selection Other FunctionsSelecting antenna Weather channel operation Dial function assignmentWeather channel selection Turn the weather alert function OFF in set mode Cloning between receivers Push SQL on the master receiverCloning using a personal computer Auto power-off functionCloning error Partial reset Frequency Table TV channelsDU.S.A. channels Dccir channelsDChina channels DNewZealand ChannelsIndonesian channels DItalian channelsTaiwan channels FOT channelsVHF marine channels Weather channelsunit MHzMurs channels Other communications in the USAHF CB Citizens Band channels General aviation frequencies Wireless MicrophonesDCable TV IRC Other communications- other countries LPD Low Power Device channels Unit MHzPMR446 channels unit MHz UHF C.R.S Citizen Radio Service channels Maintenance TroubleshootingCP-18A/E fuse replacement Specifications DgeneralOptions OptionsPocket Guide Memory channel programming Declaration Conformity We Icom Inc. JapanKamiminami, Hirano-ku, Osaka 547-0003 Japan