Icom IC-R5 DTone frequency Ddtcs code, Dtcs polarity, Available subaudible tone frequencies

Page 57

 

SET MODE 9

DTone frequency

DDTCS code

Sets subaudible tone frequency for tone squelch operation.

Sets DTCS code for DTCS squelch operation. Total of 104

Total of 50 tone frequencies (67.0–254.1 Hz) are available.

codes (023–754) are available.

(default: 88.5 Hz)

(default: 023)

88.5 Hz setting

254.1 Hz setting

Code 023 setting

Code 754 setting

Available subaudible tone frequencies

67.0

79.7

94.8

110.9

131.8

156.7

171.3

186.2

203.5

229.1

69.3

82.5

97.4

114.8

136.5

159.8

173.8

189.9

206.5

233.6

71.9

85.4

100.0

118.8

141.3

162.2

177.3

192.8

210.7

241.8

74.4

88.5

103.5

123.0

146.2

165.5

179.9

196.6

218.1

250.3

77.0

91.5

107.2

127.3

151.4

167.9

183.5

199.5

225.7

254.1

 

 

 

 

 

 

 

 

 

 

Available DTCS code

023

054

125

165

245

274

356

445

506

627

732

025

065

131

172

246

306

364

446

516

631

734

026

071

132

174

251

311

365

452

523

632

743

031

072

134

205

252

315

371

454

526

654

754

032

073

143

212

255

325

411

455

532

662

 

036

074

145

223

261

331

412

462

546

664

 

043

114

152

225

263

332

413

464

565

703

 

047

115

155

226

265

343

423

465

606

712

 

051

116

156

243

266

346

431

466

612

723

 

053

122

162

244

271

351

432

503

624

731

 

 

 

 

 

 

 

 

 

 

 

 

9

The polarity can also be set in “DTCS polarity” as follow.

DDTCS polarity

Sets DTCS polarity from normal and reverse.

(default: NORMAL)

Normal setting

Reverse setting

46

Image 57
Contents IR5 Explicit Definitions Precaution Iii Supplied AccessoriesTable of Contents Quick Reference Guide Battery installationPreparation Belt clipInstall the Ni-Cd batteries Rotate Dial to select Y then push BandCharging confirmation is displayed as below About default setting Your first scanning ExperienceBasic operation Setting frequency Receive mode selectionMemory programming Selecting a memory ChannelProgramming scan edges Programmed scan operationSelecting a scan edge channel a Selecting a scan edge channel BCancelling scan Starting scan Select VFO modeSelecting a scanning type Starting scanFront, top and side panels Panel DescriptionUCONTROL Dial Dial Push for 1 sec. to turn the receiver power on and OFFERECEIVE Mode Indicator p WLOCK Indicator pRDUPLEX Indicators p TTONE IndicatorsPriority Watch Indicator p 1SIGNAL Strength Indicator p2VOLUME Exchange Indicator p Battery installation Battery ChargingBattery caution Charging cautionCharging connections Battery chargingCharging description Charging periods Approx hoursFrequency and Channel Setting VFO and memory channelsOperating band selection Available frequency bands Frequency and Channel SettingSetting a tuning step Setting a frequencyTuning step selection Rotate Dial to select the desired frequency bandSelecting a memory channel Push V/MS.MW~ to select the memory modeLock function Rotate Dial to select the desired memory channelWhen a signal is received Setting audio volumeBasic Operation ReceivingReceive mode selection Squelch level settingMonitor function Attenuator functionPush and hold SQL to monitor the operating frequency Setting Duplex operationRotate Dial to select DUP Setting dial select step Push Tsset momentarily to exit set modeDial select step General description Memory ChannelsMemory bank setting Rotate Dial to select the desired bank channel numberPush V/MS.MW~ momentarily to set the channel into the bank Push V/MS.MW~ to select memory mode, if desired Memory bank selectionRotate Dial to select the bank channel To return to regular memory condition, rotate Dial whileProgramming memory/bank name Rotate Dial to move the cursor to left or rightAvailable characters Selecting bank channel indication Selecting display typeCopying memory contents Memory clearing Push V/MS.MW~ for 1 sec. to clear the contentsWhile pushing FUNC, push V/MS.MW~ for 1 sec EssaryTransferring memory contents Erasing/transferring bank contents Scan types Scan OperationFull Scan p FREQUENCY/MEMORY Skip Function pSelect VFO mode with V/MS.MW~ Full/band/programmed scanTo start the scan, push Modescan Example Programming 145.300 MHz into scan edges 03A Scan edges programmingMemory/bank/all bank scan Select memory mode with V/MS.MW~During auto-memory write scanning Auto memory write scanRe-calling the stored frequencies Clearing the stored frequenciesNel Skip channel/frequency settingScan pause timer Scan resume timerScan resume condition Priority watch types Priority WatchAbout priority beep function Watch startsPush Tsset to cancel the watch Push Tsset to exit set mode and start the watchPriority watch operation Select memory mode, or the desired bank group thenVFO scan watch qSelect memory mode When scanning memory/bank channels0Push Tsset to cancel the watch and scan Tone/DTCS squelch operation Tone Squelch and Pocket BeepOPush Func to stop the beeps and blinking manually Step yTone squelch frequency/DTCS code setting Available Dtcs code listAvailable tone frequency list Dtcs polarity setting While pushing FUNC, push Modescan to start the tone scan Tone scanSet mode entering and operation SET ModeExpanded set mode ON/OFF GeneralSet mode items General set mode itemsExpanded set mode items Priority watch Dial select stepKey-touch beep Beep output levelPower save Antenna selectionMHz differ according to version, re No accessible switch is available, except Monitor switch actionKey lock effect Dial speed accelerationScan pause timer Auto power OFFScan resume timer Scan stop beepOffset frequency Duplex directionTone squelch Dtcs polarity DTone frequency Ddtcs codeAvailable subaudible tone frequencies Available Dtcs codeLCD contrast Weather alert functionTurns weather alert function on and OFF Other Functions Antenna selectionSelecting antenna Dial function assignment Weather channel operationWeather channel selection Turn the weather alert function OFF in set mode Push SQL on the master receiver Cloning between receiversAuto power-off function Cloning using a personal computerCloning error Partial reset TV channels Frequency TableDU.S.A. channels Dccir channelsDNew DChina channelsZealand ChannelsDItalian channels Indonesian channelsTaiwan channels FOT channelsWeather channelsunit MHz VHF marine channelsOther communications in the USA Murs channelsHF CB Citizens Band channels Wireless Microphones General aviation frequenciesDCable TV IRC LPD Low Power Device channels Unit MHz Other communications- other countriesPMR446 channels unit MHz UHF C.R.S Citizen Radio Service channels Troubleshooting MaintenanceCP-18A/E fuse replacement Dgeneral SpecificationsOptions OptionsPocket Guide Memory channel programming We Icom Inc. Japan Declaration ConformityKamiminami, Hirano-ku, Osaka 547-0003 Japan