SUPPLIED ACCESSORIES

q

w

e

r

t

qAntenna ………………………………………………………1

wHand strap …………………………………………………1

eBelt clip ………………………………………………………1

rNi-Cd battery cells…………………………………………2

tAC adapter* …………………………………………………1

*Not supplied with UK and Italy versions.

Not supplied with Italy version.

OPERATING THEORY

Electromagnetic radiation which has frequencies of 20,000 Hz (20 kHz*) and above is called radio frequency (RF) energy because it is useful in radio transmissions. The IC-R5 receives RF energy from 0.150 MHz* to 1309.995 MHz and converts it into audio frequency (AF) energy which in turn ac- tuates a loudspeaker to create sound waves. AF energy is in the range of 20 to 20,000 Hz.

*kHz is an abbreviation of kilohertz or 1000 hertz, MHz is abbreviation of megahertz or 1,000,000 hertz, where hertz is a unit of frequency.

OPERATING NOTES

The IC-R5 may receive its own oscillated frequency, resulting in no reception or only noise reception, on some frequencies.

The IC-R5 may receive interference from extremely strong signals on different frequencies or when using an external high-gain antenna.

iii

Image 4
Contents IR5 Explicit Definitions Precaution Supplied Accessories IiiTable of Contents Battery installation Quick Reference GuidePreparation Belt clipRotate Dial to select Y then push Band Install the Ni-Cd batteriesCharging confirmation is displayed as below Your first scanning Experience About default settingBasic operation Receive mode selection Setting frequencyMemory programming Selecting a memory ChannelProgrammed scan operation Programming scan edgesSelecting a scan edge channel a Selecting a scan edge channel BStarting scan Select VFO mode Cancelling scanSelecting a scanning type Starting scanPanel Description Front, top and side panelsPush for 1 sec. to turn the receiver power on and OFF UCONTROL Dial DialWLOCK Indicator p ERECEIVE Mode Indicator pRDUPLEX Indicators p TTONE Indicators1SIGNAL Strength Indicator p Priority Watch Indicator p2VOLUME Exchange Indicator p Battery Charging Battery installationBattery caution Charging cautionBattery charging Charging connectionsCharging description Charging periods Approx hoursVFO and memory channels Frequency and Channel SettingOperating band selection Frequency and Channel Setting Available frequency bandsSetting a frequency Setting a tuning stepTuning step selection Rotate Dial to select the desired frequency bandPush V/MS.MW~ to select the memory mode Selecting a memory channelLock function Rotate Dial to select the desired memory channelSetting audio volume When a signal is receivedBasic Operation ReceivingSquelch level setting Receive mode selectionAttenuator function Monitor functionPush and hold SQL to monitor the operating frequency Duplex operation SettingRotate Dial to select DUP Push Tsset momentarily to exit set mode Setting dial select stepDial select step Memory Channels General descriptionRotate Dial to select the desired bank channel number Memory bank settingPush V/MS.MW~ momentarily to set the channel into the bank Memory bank selection Push V/MS.MW~ to select memory mode, if desiredRotate Dial to select the bank channel To return to regular memory condition, rotate Dial whileRotate Dial to move the cursor to left or right Programming memory/bank nameAvailable characters Selecting display type Selecting bank channel indicationCopying memory contents Push V/MS.MW~ for 1 sec. to clear the contents Memory clearingWhile pushing FUNC, push V/MS.MW~ for 1 sec EssaryTransferring memory contents Erasing/transferring bank contents Scan Operation Scan typesFull Scan p FREQUENCY/MEMORY Skip Function pFull/band/programmed scan Select VFO mode with V/MS.MW~To start the scan, push Modescan Scan edges programming Example Programming 145.300 MHz into scan edges 03ASelect memory mode with V/MS.MW~ Memory/bank/all bank scanAuto memory write scan During auto-memory write scanningRe-calling the stored frequencies Clearing the stored frequenciesSkip channel/frequency setting NelScan resume timer Scan pause timerScan resume condition Priority Watch Priority watch typesAbout priority beep function Watch startsPush Tsset to exit set mode and start the watch Push Tsset to cancel the watchPriority watch operation Select memory mode, or the desired bank group thenWhen scanning memory/bank channels VFO scan watch qSelect memory mode0Push Tsset to cancel the watch and scan Tone Squelch and Pocket Beep Tone/DTCS squelch operationOPush Func to stop the beeps and blinking manually Step yAvailable Dtcs code list Tone squelch frequency/DTCS code settingAvailable tone frequency list Dtcs polarity setting Tone scan While pushing FUNC, push Modescan to start the tone scanSET Mode Set mode entering and operationExpanded set mode ON/OFF GeneralGeneral set mode items Set mode itemsExpanded set mode items Dial select step Priority watchKey-touch beep Beep output levelAntenna selection Power saveMHz differ according to version, re Monitor switch action No accessible switch is available, exceptKey lock effect Dial speed accelerationAuto power OFF Scan pause timerScan resume timer Scan stop beepDuplex direction Offset frequencyTone squelch DTone frequency Ddtcs code Dtcs polarityAvailable subaudible tone frequencies Available Dtcs codeWeather alert function LCD contrastTurns weather alert function on and OFF Antenna selection Other FunctionsSelecting antenna Weather channel operation Dial function assignmentWeather channel selection Turn the weather alert function OFF in set mode Cloning between receivers Push SQL on the master receiverCloning using a personal computer Auto power-off functionCloning error Partial reset Frequency Table TV channelsDU.S.A. channels Dccir channelsDChina channels DNewZealand ChannelsIndonesian channels DItalian channelsTaiwan channels FOT channelsVHF marine channels Weather channelsunit MHzMurs channels Other communications in the USAHF CB Citizens Band channels General aviation frequencies Wireless MicrophonesDCable TV IRC Other communications- other countries LPD Low Power Device channels Unit MHzPMR446 channels unit MHz UHF C.R.S Citizen Radio Service channels Maintenance TroubleshootingCP-18A/E fuse replacement Specifications DgeneralOptions OptionsPocket Guide Memory channel programming Declaration Conformity We Icom Inc. JapanKamiminami, Hirano-ku, Osaka 547-0003 Japan