Seagate FR-A7AY instruction manual Parameter List

Page 15

PARAMETER LIST

 

Parameter

Name

Setting Range

Minimum

Initial

Refer to

 

Number

Increments

Value

Page

 

 

 

OUTPUT

313

DO0 output selection

0 to 5, (7), 8, 10 to 19,

 

 

21 and

 

 

99, 100 to 105, (107),

 

 

 

314

DO1 output selection

25, 26, 45 to 47, 64, 70,

 

 

 

 

315

DO2 output selection

(71 to 78), 86 to 96, 98,

 

 

 

 

 

 

 

 

DIGITAL

316

DO3 output selection

108, 110 to 116, 125,

1

9999

later

317

DO4 output selection

 

 

126, 145 to 147, 164,

 

 

 

 

 

 

 

 

318

DO5 output selection

170, 186 to 196, 198,

 

 

 

 

319

DO6 output selection

199, 9999

 

 

 

10

Image 15
Contents FR-A7AY Safety Instructions This section is specifically about Safety mattersInjury Prevention  Contents  Digital Output PRE-OPERATION Instructions Unpacking and Product ConfirmationPacking confirmation Terminal layout PartsFront view Rear viewOutput signals SpecificationsMemo Pre-Installation Instructions Installation and WiringRemove the inverter front cover Installation Procedure Tightening Torque Cable Size Wiring30K or less 37K or more Name Setting Range Minimum Initial Refer to Number Parameter ListValue Parameter List Extension Analog Output Wiring ExampleInternal Block Diagram Terminals Terminal Symbol Terminal Name DescriptionExtension Analog Output Function Parameter List Parameter Name Setting Range Minimum Initial NumberSetting Adjustment ProcedureStart Calibration of meterExtension Analog Output Types of Monitor Increments Full-Scale Value Output signal settingWhen Pr = 0 When Pr = 10 Analog signal adjustment Pr , Pr , Pr , PrInstructions Digital Output Digital Output Digital Output Function Parameter List Name Initial Value Setting RangeFunction Output Signal ListSetting Function SettingRO2 Print Date Manual Number Revision Revisions