2. Injury Prevention

CAUTION

Apply only the voltage specified in the instruction manual to each terminal. Otherwise, burst, damage, etc. may occur.

Ensure that the cables are connected to the correct terminals. Otherwise, burst, damage, etc. may occur.

Always make sure that polarity is correct to prevent damage, etc. Otherwise, burst, damage may occur.

While power is on or for some time after power-off, do not touch the inverter as it is hot and you may get burnt.

3. Additional Instructions

Also note the following points to prevent an accidental failure, injury, electric shock, etc.

1) Transportation and mounting

CAUTION

Do not install or operate the plug-in option if it is damaged or has parts missing.

Do not stand or rest heavy objects on the product.

Check that the mounting orientation is correct.

Prevent other conductive bodies such as screws and metal fragments or other flammable substance such as oil from entering the inverter.

2) Trial run

CAUTION

Before starting operation, confirm and adjust the parameters. A failure to do so may cause some machines to make unexpected motions.

3) Usage

WARNING

Do not modify the equipment.

Do not perform parts removal which is not instructed in this manual. Doing so may lead to fault or damage of the inverter.

CAUTION

When parameter clear or all parameter clear is performed, reset the required parameters before starting operations. Each parameter returns to the initial value.

For prevention of damage due to static electricity, touch nearby metal before touching this product to eliminate static electricity from your body.

4) Maintenance, inspection and parts replacement

CAUTION

Do not test the equipment with a megger (measure insulation resistance).

5) Disposal

CAUTION

Treat as industrial waste.

6) General instruction

All illustrations given in this manual may have been drawn with covers or safety guards removed to provide in-depth description. Before starting operation of the product, always return the covers and guards into original positions as specified and operate the equipment in accordance with the manual.

A-2

Image 3
Contents FR-A7AY Safety Instructions This section is specifically about Safety mattersInjury Prevention  Contents  Digital Output PRE-OPERATION Instructions Unpacking and Product ConfirmationPacking confirmation Terminal layout PartsFront view Rear viewOutput signals SpecificationsMemo Pre-Installation Instructions Installation and WiringRemove the inverter front cover Installation ProcedureTightening Torque Cable Size Wiring30K or less 37K or more Name Setting Range Minimum Initial Refer to Number Parameter ListValue Parameter List Extension Analog Output Wiring ExampleInternal Block Diagram Terminals Terminal Symbol Terminal Name DescriptionExtension Analog Output Function Parameter List Parameter Name Setting Range Minimum Initial NumberSetting Adjustment ProcedureStart Calibration of meterExtension Analog Output Types of Monitor Increments Full-Scale Value Output signal settingWhen Pr = 0 When Pr = 10 Analog signal adjustment Pr , Pr , Pr , PrInstructions Digital Output Digital Output Digital Output Function Parameter List Name Initial Value Setting RangeFunction Output Signal ListSetting Function SettingRO2 Print Date Manual Number Revision Revisions