Seagate FR-A7AY Output signal setting, Types of Monitor Increments Full-Scale Value

Page 23

EXTENSION ANALOG OUTPUT

4.5.3Output signal setting

Set the output signals to be monitored. Set Pr. 306 to output the same signal from terminals AM0 and AM1 and Pr. 306 and Pr. 310 to output different signals. For details of signal definitions, refer to Pr. 54 and Pr. 158 of the inverter manual (applied).

Pr. 306/Pr. 310

Types of Monitor

Increments

Full-Scale Value

Setting

 

 

 

1

Output frequency

0.01Hz

Pr. 55

2

Output current

0.01A/0.1A *2

Pr. 56

3

Output voltage

0.1V

800V

5

Frequency setting

0.01Hz

Pr. 55

6

Running speed

1(r/min)

The value converted with the Pr. 37 value from Pr. 55.

8

Converter output voltage

0.1V

800V

9 *1

Regenerative brake duty

0.1%

Pr. 70

10

Electronic thermal relay

0.1%

Electronic thermal relay function operation level

function load factor

 

 

 

11

Output current peak value

0.01A/0.1A *2

Pr. 56

12

Converter output voltage

0.1V

800V

peak value

 

 

 

13

Input power

0.01kW/0.1kW *2

Rated inverter power × 2

14

Output power

0.01kW/0.1kW *2

Rated inverter power × 2

17

Load meter

0.1%

Pr. 56

21

Reference voltage output

24

Motor load factor

0.1%

200%

50

Power saving effect

Variable according to parameters

Inverter capacity

52

PID set point

0.1%

100%

53

PID process value

0.1%

100%

*1 Setting can be made only for the 75K(01800-EC, S75K-CH) or more.

*2 The setting depends on capacities. (55K (01160-EC, 55K-CH) or less/75K (01800-EC, S75K-CH) or more.)

18

Image 23
Contents FR-A7AY Safety Instructions This section is specifically about Safety mattersInjury Prevention  Contents  Digital Output Packing confirmation PRE-OPERATION InstructionsUnpacking and Product Confirmation Terminal layout PartsFront view Rear viewOutput signals SpecificationsMemo Pre-Installation Instructions Installation and WiringRemove the inverter front cover Installation ProcedureTightening Torque Cable Size Wiring30K or less 37K or more Value Name Setting Range Minimum Initial Refer to NumberParameter List Parameter List Extension Analog Output Wiring ExampleInternal Block Diagram Terminals Terminal Symbol Terminal Name DescriptionExtension Analog Output Function Parameter List Parameter Name Setting Range Minimum Initial NumberSetting Adjustment ProcedureStart Calibration of meterExtension Analog Output Types of Monitor Increments Full-Scale Value Output signal settingWhen Pr = 0 When Pr = 10 Analog signal adjustment Pr , Pr , Pr , PrInstructions Digital Output Digital Output Digital Output Function Parameter List Name Initial Value Setting RangeFunction Output Signal ListSetting Function SettingRO2 Print Date Manual Number Revision Revisions